These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
124 related articles for article (PubMed ID: 28943598)
1. The Piezo Actuator-Driven Pulsed Water Jet System for Minimizing Renal Damage after Off-Clamp Laparoscopic Partial Nephrectomy. Kamiyama Y; Yamashita S; Nakagawa A; Fujii S; Mitsuzuka K; Kaiho Y; Ito A; Abe T; Tominaga T; Arai Y Tohoku J Exp Med; 2017 Sep; 243(1):57-65. PubMed ID: 28943598 [TBL] [Abstract][Full Text] [Related]
2. Effects of a Novel Piezo Actuator-driven Pulsed Water Jet System on Residual Kidney After Partial Nephrectomy in a Rat Model. Kamiyama Y; Yamashita S; Nakagawa A; Fujii S; Goto T; Mitsuzuka K; Ito A; Abe T; Tominaga T; Arai Y Urology; 2019 Jan; 123():265-272. PubMed ID: 30359707 [TBL] [Abstract][Full Text] [Related]
3. Off-clamp versus complete hilar control laparoscopic partial nephrectomy: comparison by clinical stage. Rais-Bahrami S; George AK; Herati AS; Srinivasan AK; Richstone L; Kavoussi LR BJU Int; 2012 May; 109(9):1376-81. PubMed ID: 21992566 [TBL] [Abstract][Full Text] [Related]
4. Ventricle wall dissection and vascular preservation with the pulsed water jet device: novel tissue dissector for flexible neuroendoscopic surgery. Kawaguchi T; Nakagawa A; Endo T; Fujimura M; Sonoda Y; Tominaga T J Neurosurg; 2016 Mar; 124(3):817-22. PubMed ID: 26406794 [TBL] [Abstract][Full Text] [Related]
5. The dissection profile and mechanism of tissue-selective dissection of the piezo actuator-driven pulsed water jet as a surgical instrument: laboratory investigation using Swine liver. Yamada M; Nakano T; Sato C; Nakagawa A; Fujishima F; Kawagishi N; Nakanishi C; Sakurai T; Miyata G; Tominaga T; Ohuchi N Eur Surg Res; 2014; 53(1-4):61-72. PubMed ID: 25139450 [TBL] [Abstract][Full Text] [Related]
7. Nephrometry score-guided off-clamp laparoscopic partial nephrectomy: patient selection and short-time functional results. Wang HK; Qin XJ; Ma CG; Shi GH; Zhang HL; Ye DW World J Surg Oncol; 2016 Jun; 14(1):163. PubMed ID: 27329038 [TBL] [Abstract][Full Text] [Related]
8. Nonischemic laparoscopic partial nephrectomy using a novel wet monopolar device in a porcine model. Mues AC; Graversen JA; Korets R; O'Toole KM; Polland A; Badani KK; Gupta M; Landman J J Endourol; 2012 Jun; 26(6):592-6. PubMed ID: 22010974 [TBL] [Abstract][Full Text] [Related]
9. Recent advances in laparoscopic partial nephrectomy: comparative study of electrosurgical snare electrode and ultrasound dissection. Elashry OM; Wolf JS; Rayala HJ; McDougall EM; Clayman RV J Endourol; 1997 Feb; 11(1):15-22. PubMed ID: 9048292 [TBL] [Abstract][Full Text] [Related]
10. Laparoscopic Partial Nephrectomy with a Remotely Activated Bulldog Clamp in a Pig Model. Chen W; Guo JM; Hou J; Wang GM J Endourol; 2017 Jan; 31(1):66-71. PubMed ID: 27762624 [TBL] [Abstract][Full Text] [Related]
11. To clamp or not to clamp? Long-term functional outcomes for elective off-clamp laparoscopic partial nephrectomy. Shah PH; George AK; Moreira DM; Alom M; Okhunov Z; Salami S; Waingankar N; Schwartz MJ; Vira MA; Richstone L; Kavoussi LR BJU Int; 2016 Feb; 117(2):293-9. PubMed ID: 26348366 [TBL] [Abstract][Full Text] [Related]
12. Accuracy of Urinary Neutrophil Gelatinase-Associated Lipocalin in Quantifying Acute Kidney Injury after Partial Nephrectomy in Patients with Normal Contralateral Kidney. Koo KC; Hong JH; Lee HS; Jeh SU; Choi YD; Rha KH; Ham WS PLoS One; 2015; 10(7):e0133675. PubMed ID: 26200468 [TBL] [Abstract][Full Text] [Related]
13. Laparoscopic partial nephrectomy with selective control of the renal parenchyma: initial experience with a novel laparoscopic clamp. Simon J; Bartsch G; Finter F; Hautmann R; de Petriconi R BJU Int; 2009 Mar; 103(6):805-8. PubMed ID: 19007377 [TBL] [Abstract][Full Text] [Related]
14. Application of actuator-driven pulsed water jet for coronary artery bypass grafting: assessment in a swine model. Suzuki T; Kawamoto S; Nakagawa A; Endo T; Tominaga T; Akiyama M; Adachi O; Kumagai K; Saiki Y J Artif Organs; 2018 Jun; 21(2):247-253. PubMed ID: 29147809 [TBL] [Abstract][Full Text] [Related]
15. Use of Actuator-Driven Pulsed Water Jet in Brain and Spinal Cord Cavernous Malformations Resection. Endo T; Takahashi Y; Nakagawa A; Niizuma K; Fujimura M; Tominaga T Neurosurgery; 2015 Sep; 11 Suppl 3():394-403; discussion 403. PubMed ID: 26284350 [TBL] [Abstract][Full Text] [Related]
16. Commentary on "Off-clamp vs. complete hilar control laparoscopic partial nephrectomy: Comparison by clinical stage." Rais-Bahrami S, George AK, Herati AS, Srinivasan AK, Richstone L, Kavoussi LR, Arthur Smith Institute for Urology, North Shore-Long Island Jewish Health System, New Hyde Park, NY: BJU Int 2012;109(9):1376-81 (Epub 2011 Oct 12). Boorjian S Urol Oncol; 2013 Jan; 31(1):129-30. PubMed ID: 23419726 [TBL] [Abstract][Full Text] [Related]
17. Piezo Actuator-Driven Pulsed Water Jet for Neurosurgery: Laboratory Evaluation with the Swine Model and Implications of Mechanical Properties. Nakagawa A; Endo T; Kawaguchi T; Yamada M; Sato C; Kumabe T; Iwasaki M; Niizuma K; Kanamori M; Nakanishi C; Yamashita S; Nakano T; Tominaga T J Neurol Surg A Cent Eur Neurosurg; 2022 Oct; ():. PubMed ID: 36252769 [TBL] [Abstract][Full Text] [Related]
19. Water jet assisted laparoscopic partial nephrectomy without hilar clamping in the calf model. Moinzadeh A; Hasan W; Spaliviero M; Finelli A; Kilciler M; Magi-Galluzzi C; El Gabry E; Desai M; Kaouk J; Gill IS J Urol; 2005 Jul; 174(1):317-21. PubMed ID: 15947682 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of a newly developed piezo actuator-driven pulsed water jet system for liver resection in a surviving swine animal model. Nakanishi C; Nakano T; Nakagawa A; Sato C; Yamada M; Kawagishi N; Tominaga T; Ohuchi N Biomed Eng Online; 2016 Jan; 15():9. PubMed ID: 26809992 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]