457 related articles for article (PubMed ID: 28945787)
1. Rapid colorimetric detection of Zika virus from serum and urine specimens by reverse transcription loop-mediated isothermal amplification (RT-LAMP).
Calvert AE; Biggerstaff BJ; Tanner NA; Lauterbach M; Lanciotti RS
PLoS One; 2017; 12(9):e0185340. PubMed ID: 28945787
[TBL] [Abstract][Full Text] [Related]
2. Development and validation of a one-step reverse transcription loop-mediated isothermal amplification (RT-LAMP) for rapid detection of ZIKV in patient samples from Brazil.
da Silva SJR; Pardee K; Balasuriya UBR; Pena L
Sci Rep; 2021 Feb; 11(1):4111. PubMed ID: 33602985
[TBL] [Abstract][Full Text] [Related]
3. Rapid and sensitive detection of Zika virus by reverse transcription loop-mediated isothermal amplification.
Wang X; Yin F; Bi Y; Cheng G; Li J; Hou L; Li Y; Yang B; Liu W; Yang L
J Virol Methods; 2016 Dec; 238():86-93. PubMed ID: 27793644
[TBL] [Abstract][Full Text] [Related]
4. Development of Universal and Lineage-Specific Primer Sets for Rapid Detection of the Zika Virus (ZIKV) in Blood and Urine Samples Using One-Step Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP).
Bui TT; Moi ML; Morita K; Hasebe F
Jpn J Infect Dis; 2020 Mar; 73(2):153-156. PubMed ID: 31666491
[TBL] [Abstract][Full Text] [Related]
5. Point of sampling detection of Zika virus within a multiplexed kit capable of detecting dengue and chikungunya.
Yaren O; Alto BW; Gangodkar PV; Ranade SR; Patil KN; Bradley KM; Yang Z; Phadke N; Benner SA
BMC Infect Dis; 2017 Apr; 17(1):293. PubMed ID: 28427352
[TBL] [Abstract][Full Text] [Related]
6. Detection of Zika Virus Using Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP).
Lamb LE; Bartolone SN; Chancellor MB
Methods Mol Biol; 2020; 2142():137-146. PubMed ID: 32367365
[TBL] [Abstract][Full Text] [Related]
7. A reverse transcription loop-mediated isothermal amplification for broad coverage detection of Asian and African Zika virus lineages.
Teoh BT; Chin KL; Samsudin NI; Loong SK; Sam SS; Tan KK; Khor CS; Abd-Jamil J; Zainal N; Wilder-Smith A; Zandi K; AbuBakar S
BMC Infect Dis; 2020 Dec; 20(1):947. PubMed ID: 33308203
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of a field-deployable reverse transcription-insulated isothermal PCR for rapid and sensitive on-site detection of Zika virus.
Carossino M; Li Y; Lee PA; Tsai CF; Chou PH; Williams D; Skillman A; Frank Cook R; Brown G; Chang HG; Wang HT; Balasuriya UBR
BMC Infect Dis; 2017 Dec; 17(1):778. PubMed ID: 29258444
[TBL] [Abstract][Full Text] [Related]
9. Development and Validation of Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) for Rapid Detection of ZIKV in Mosquito Samples from Brazil.
Silva SJRD; Paiva MHS; Guedes DRD; Krokovsky L; Melo FL; Silva MALD; Silva AD; Ayres CFJ; Pena LJ
Sci Rep; 2019 Mar; 9(1):4494. PubMed ID: 30872672
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of Aptima Zika Virus Assay.
Ren P; Ortiz DA; Terzian ACB; Colombo TE; Nogueira ML; Vasilakis N; Loeffelholz MJ
J Clin Microbiol; 2017 Jul; 55(7):2198-2203. PubMed ID: 28468854
[TBL] [Abstract][Full Text] [Related]
11. Ten-minute direct detection of Zika virus in serum samples by RT-LAMP.
Estrela PFN; Mendes GM; de Oliveira KG; Bailão AM; Soares CMA; Assunção NA; Duarte GRM
J Virol Methods; 2019 Sep; 271():113675. PubMed ID: 31170469
[TBL] [Abstract][Full Text] [Related]
12. Development and evaluation of one-step multiplex real-time RT-PCR assay for simultaneous detection of Zika virus and Chikungunya virus.
Liu SQ; Li X; Deng CL; Yuan ZM; Zhang B
J Med Virol; 2018 Mar; 90(3):389-396. PubMed ID: 28980717
[TBL] [Abstract][Full Text] [Related]
13. One-step pentaplex real-time polymerase chain reaction assay for detection of zika, dengue, chikungunya, West nile viruses and a human housekeeping gene.
Mishra N; Ng J; Rakeman JL; Perry MJ; Centurioni DA; Dean AB; Price A; Thakkar R; Angus AG; Williamson P; Delwart E; Carrington C; Sahadeo N; Che X; Briese T; Tokarz R; Lipkin WI
J Clin Virol; 2019 Nov; 120():44-50. PubMed ID: 31557664
[TBL] [Abstract][Full Text] [Related]
14. Simpler, Faster, and Sensitive Zika Virus Assay Using Smartphone Detection of Loop-mediated Isothermal Amplification on Paper Microfluidic Chips.
Kaarj K; Akarapipad P; Yoon JY
Sci Rep; 2018 Aug; 8(1):12438. PubMed ID: 30127503
[TBL] [Abstract][Full Text] [Related]
15. Reverse Transcription-Loop-mediated Isothermal Amplification (RT-LAMP) Assay for Zika Virus and Housekeeping Genes in Urine, Serum, and Mosquito Samples.
Bartolone SN; Tree MO; Conway MJ; Chancellor MB; Lamb LE
J Vis Exp; 2018 Sep; (139):. PubMed ID: 30272674
[TBL] [Abstract][Full Text] [Related]
16. Simple and Highly Sensitive Molecular Diagnosis of Zika Virus by Lateral Flow Assays.
Lee D; Shin Y; Chung S; Hwang KS; Yoon DS; Lee JH
Anal Chem; 2016 Dec; 88(24):12272-12278. PubMed ID: 28193014
[TBL] [Abstract][Full Text] [Related]
17. Development and evaluation of a visible reverse transcription-loop-mediated isothermal amplification (RT-LAMP) for the detection of Asian lineage ZIKV in field-caught mosquitoes.
Siriyasatien P; Wacharapluesadee S; Kraivichian K; Suwanbamrung C; Sutthanont N; Cantos-Barreda A; Phumee A
Acta Trop; 2022 Dec; 236():106691. PubMed ID: 36103950
[TBL] [Abstract][Full Text] [Related]
18. JEV-nanobarcode and colorimetric reverse transcription loop-mediated isothermal amplification (cRT-LAMP).
Ahn G; Lee SH; Song MS; Han BK; Kim YH; Ahn JY
Mikrochim Acta; 2021 Sep; 188(10):333. PubMed ID: 34498149
[TBL] [Abstract][Full Text] [Related]
19. Detection of Zika virus using reverse-transcription LAMP coupled with reverse dot blot analysis in saliva.
Sabalza M; Yasmin R; Barber CA; Castro T; Malamud D; Kim BJ; Zhu H; Montagna RA; Abrams WR
PLoS One; 2018; 13(2):e0192398. PubMed ID: 29401479
[TBL] [Abstract][Full Text] [Related]
20. Improved detection of Zika virus RNA in human and animal specimens by a novel, highly sensitive and specific real-time RT-PCR assay targeting the 5'-untranslated region of Zika virus.
Chan JF; Yip CC; Tee KM; Zhu Z; Tsang JO; Chik KK; Tsang TG; Chan CC; Poon VK; Sridhar S; Yin F; Hung IF; Chau SK; Zhang AJ; Chan KH; Yuen KY
Trop Med Int Health; 2017 May; 22(5):594-603. PubMed ID: 28214373
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]