BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

543 related articles for article (PubMed ID: 28951183)

  • 21. Rate and mode of screw misplacements after 3D-fluoroscopy navigation-assisted insertion and 3D-imaging control of 1547 pedicle screws in spinal levels T10-S1 related to vertebrae and spinal sections.
    Balling H; Blattert TR
    Eur Spine J; 2017 Nov; 26(11):2898-2905. PubMed ID: 28551828
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The European Robotic Spinal Instrumentation (EUROSPIN) study: protocol for a multicentre prospective observational study of pedicle screw revision surgery after robot-guided, navigated and freehand thoracolumbar spinal fusion.
    Staartjes VE; Molliqaj G; van Kampen PM; Eversdijk HAJ; Amelot A; Bettag C; Wolfs JFC; Urbanski S; Hedayat F; Schneekloth CG; Abu Saris M; Lefranc M; Peltier J; Boscherini D; Fiss I; Schatlo B; Rohde V; Ryang YM; Krieg SM; Meyer B; Kögl N; Girod PP; Thomé C; Twisk JWR; Tessitore E; Schröder ML
    BMJ Open; 2019 Sep; 9(9):e030389. PubMed ID: 31501123
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Use of the Airo mobile intraoperative CT system versus the O-arm for transpedicular screw fixation in the thoracic and lumbar spine: a retrospective cohort study of 263 patients.
    Scarone P; Vincenzo G; Distefano D; Del Grande F; Cianfoni A; Presilla S; Reinert M
    J Neurosurg Spine; 2018 Oct; 29(4):397-406. PubMed ID: 29979141
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine.
    Conrads N; Grunz JP; Huflage H; Luetkens KS; Feldle P; Grunz K; Köhler S; Westermaier T
    Arch Orthop Trauma Surg; 2023 Jun; 143(6):3007-3013. PubMed ID: 35794344
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Intraoperative control of pedicle screw position using three-dimensional fluoroscopy. A prospective study in thoracolumbar fractures].
    Beck M; Moritz K; Gierer P; Gradl G; Harms C; Mittlmeier T
    Z Orthop Unfall; 2009; 147(1):37-42. PubMed ID: 19263311
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of robot-assisted and freehand pedicle screw placement for lumbar revision surgery.
    Zhang JN; Fan Y; He X; Liu TJ; Hao DJ
    Int Orthop; 2021 Jun; 45(6):1531-1538. PubMed ID: 32989559
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of novel machine vision spinal image guidance system with existing 3D fluoroscopy-based navigation system: a randomized prospective study.
    Malham GM; Munday NR
    Spine J; 2022 Apr; 22(4):561-569. PubMed ID: 34666179
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Robotic versus fluoroscopy-guided pedicle screw insertion for metastatic spinal disease: a matched-cohort comparison.
    Solomiichuk V; Fleischhammer J; Molliqaj G; Warda J; Alaid A; von Eckardstein K; Schaller K; Tessitore E; Rohde V; Schatlo B
    Neurosurg Focus; 2017 May; 42(5):E13. PubMed ID: 28463620
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: screw accuracy, screw size, and the complexity of surgery.
    Luther N; Iorgulescu JB; Geannette C; Gebhard H; Saleh T; Tsiouris AJ; Härtl R
    J Spinal Disord Tech; 2015 Jun; 28(5):E298-303. PubMed ID: 23511642
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Clinical accuracy of fluoroscopic navigation at the thoracic and lumbar spine].
    Arand M; Teller S; Gebhard F; Schultheiss M; Keppler P
    Zentralbl Chir; 2008 Dec; 133(6):597-601. PubMed ID: 19090441
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Prospective Comparison Study Between the Fluoroscopy-guided and Navigation Coupled With O-arm-guided Pedicle Screw Placement in the Thoracic and Lumbosacral Spines.
    Shin MH; Hur JW; Ryu KS; Park CK
    J Spinal Disord Tech; 2015 Jul; 28(6):E347-51. PubMed ID: 23563342
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Radiation exposure to the surgeon and the patient during posterior lumbar spinal instrumentation: a prospective randomized comparison of navigated versus non-navigated freehand techniques.
    Villard J; Ryang YM; Demetriades AK; Reinke A; Behr M; Preuss A; Meyer B; Ringel F
    Spine (Phila Pa 1976); 2014 Jun; 39(13):1004-9. PubMed ID: 24732833
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Combining pedicle screw stimulation with spinal navigation, a protocol to maximize the safety of neural elements and minimize radiation exposure in thoracolumbar spine instrumentation.
    Kassis SZ; Abukwedar LK; Msaddi AK; Majer CN; Othman W
    Eur Spine J; 2016 Jun; 25(6):1724-8. PubMed ID: 25921653
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Accuracy of fluoroscopically-assisted pedicle screw placement: analysis of 1,218 screws in 198 patients.
    Koktekir E; Ceylan D; Tatarli N; Karabagli H; Recber F; Akdemir G
    Spine J; 2014 Aug; 14(8):1702-8. PubMed ID: 24704680
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Benefit and accuracy of intraoperative 3D-imaging after pedicle screw placement: a prospective study in stabilizing thoracolumbar fractures.
    Beck M; Mittlmeier T; Gierer P; Harms C; Gradl G
    Eur Spine J; 2009 Oct; 18(10):1469-77. PubMed ID: 19513764
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Accuracy of patient-specific template-guided vs. free-hand fluoroscopically controlled pedicle screw placement in the thoracic and lumbar spine: a randomized cadaveric study.
    Farshad M; Betz M; Farshad-Amacker NA; Moser M
    Eur Spine J; 2017 Mar; 26(3):738-749. PubMed ID: 27502497
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Thoracolumbar instrumentation with CT-guided navigation (O-arm) in 270 consecutive patients: accuracy rates and lessons learned.
    Rivkin MA; Yocom SS
    Neurosurg Focus; 2014 Mar; 36(3):E7. PubMed ID: 24580008
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Does Augmented Reality Navigation Increase Pedicle Screw Density Compared to Free-Hand Technique in Deformity Surgery? Single Surgeon Case Series of 44 Patients.
    Edström E; Burström G; Persson O; Charalampidis A; Nachabe R; Gerdhem P; Elmi-Terander A
    Spine (Phila Pa 1976); 2020 Sep; 45(17):E1085-E1090. PubMed ID: 32355149
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: a prospective randomized comparison to conventional freehand screw implantation.
    Ringel F; Stüer C; Reinke A; Preuss A; Behr M; Auer F; Stoffel M; Meyer B
    Spine (Phila Pa 1976); 2012 Apr; 37(8):E496-501. PubMed ID: 22310097
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Using the freehand pedicle screw placement technique in adolescent idiopathic scoliosis surgery: what is the incidence of neurological symptoms secondary to misplaced screws?
    Dede O; Ward WT; Bosch P; Bowles AJ; Roach JW
    Spine (Phila Pa 1976); 2014 Feb; 39(4):286-90. PubMed ID: 24553446
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 28.