543 related articles for article (PubMed ID: 28951183)
21. Rate and mode of screw misplacements after 3D-fluoroscopy navigation-assisted insertion and 3D-imaging control of 1547 pedicle screws in spinal levels T10-S1 related to vertebrae and spinal sections.
Balling H; Blattert TR
Eur Spine J; 2017 Nov; 26(11):2898-2905. PubMed ID: 28551828
[TBL] [Abstract][Full Text] [Related]
22. The European Robotic Spinal Instrumentation (EUROSPIN) study: protocol for a multicentre prospective observational study of pedicle screw revision surgery after robot-guided, navigated and freehand thoracolumbar spinal fusion.
Staartjes VE; Molliqaj G; van Kampen PM; Eversdijk HAJ; Amelot A; Bettag C; Wolfs JFC; Urbanski S; Hedayat F; Schneekloth CG; Abu Saris M; Lefranc M; Peltier J; Boscherini D; Fiss I; Schatlo B; Rohde V; Ryang YM; Krieg SM; Meyer B; Kögl N; Girod PP; Thomé C; Twisk JWR; Tessitore E; Schröder ML
BMJ Open; 2019 Sep; 9(9):e030389. PubMed ID: 31501123
[TBL] [Abstract][Full Text] [Related]
23. Use of the Airo mobile intraoperative CT system versus the O-arm for transpedicular screw fixation in the thoracic and lumbar spine: a retrospective cohort study of 263 patients.
Scarone P; Vincenzo G; Distefano D; Del Grande F; Cianfoni A; Presilla S; Reinert M
J Neurosurg Spine; 2018 Oct; 29(4):397-406. PubMed ID: 29979141
[TBL] [Abstract][Full Text] [Related]
24. Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine.
Conrads N; Grunz JP; Huflage H; Luetkens KS; Feldle P; Grunz K; Köhler S; Westermaier T
Arch Orthop Trauma Surg; 2023 Jun; 143(6):3007-3013. PubMed ID: 35794344
[TBL] [Abstract][Full Text] [Related]
25. [Intraoperative control of pedicle screw position using three-dimensional fluoroscopy. A prospective study in thoracolumbar fractures].
Beck M; Moritz K; Gierer P; Gradl G; Harms C; Mittlmeier T
Z Orthop Unfall; 2009; 147(1):37-42. PubMed ID: 19263311
[TBL] [Abstract][Full Text] [Related]
26. Comparison of robot-assisted and freehand pedicle screw placement for lumbar revision surgery.
Zhang JN; Fan Y; He X; Liu TJ; Hao DJ
Int Orthop; 2021 Jun; 45(6):1531-1538. PubMed ID: 32989559
[TBL] [Abstract][Full Text] [Related]
27. Comparison of novel machine vision spinal image guidance system with existing 3D fluoroscopy-based navigation system: a randomized prospective study.
Malham GM; Munday NR
Spine J; 2022 Apr; 22(4):561-569. PubMed ID: 34666179
[TBL] [Abstract][Full Text] [Related]
28. Robotic versus fluoroscopy-guided pedicle screw insertion for metastatic spinal disease: a matched-cohort comparison.
Solomiichuk V; Fleischhammer J; Molliqaj G; Warda J; Alaid A; von Eckardstein K; Schaller K; Tessitore E; Rohde V; Schatlo B
Neurosurg Focus; 2017 May; 42(5):E13. PubMed ID: 28463620
[TBL] [Abstract][Full Text] [Related]
29. Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: screw accuracy, screw size, and the complexity of surgery.
Luther N; Iorgulescu JB; Geannette C; Gebhard H; Saleh T; Tsiouris AJ; Härtl R
J Spinal Disord Tech; 2015 Jun; 28(5):E298-303. PubMed ID: 23511642
[TBL] [Abstract][Full Text] [Related]
30. [Clinical accuracy of fluoroscopic navigation at the thoracic and lumbar spine].
Arand M; Teller S; Gebhard F; Schultheiss M; Keppler P
Zentralbl Chir; 2008 Dec; 133(6):597-601. PubMed ID: 19090441
[TBL] [Abstract][Full Text] [Related]
31. Prospective Comparison Study Between the Fluoroscopy-guided and Navigation Coupled With O-arm-guided Pedicle Screw Placement in the Thoracic and Lumbosacral Spines.
Shin MH; Hur JW; Ryu KS; Park CK
J Spinal Disord Tech; 2015 Jul; 28(6):E347-51. PubMed ID: 23563342
[TBL] [Abstract][Full Text] [Related]
32. Radiation exposure to the surgeon and the patient during posterior lumbar spinal instrumentation: a prospective randomized comparison of navigated versus non-navigated freehand techniques.
Villard J; Ryang YM; Demetriades AK; Reinke A; Behr M; Preuss A; Meyer B; Ringel F
Spine (Phila Pa 1976); 2014 Jun; 39(13):1004-9. PubMed ID: 24732833
[TBL] [Abstract][Full Text] [Related]
33. Combining pedicle screw stimulation with spinal navigation, a protocol to maximize the safety of neural elements and minimize radiation exposure in thoracolumbar spine instrumentation.
Kassis SZ; Abukwedar LK; Msaddi AK; Majer CN; Othman W
Eur Spine J; 2016 Jun; 25(6):1724-8. PubMed ID: 25921653
[TBL] [Abstract][Full Text] [Related]
34. Accuracy of fluoroscopically-assisted pedicle screw placement: analysis of 1,218 screws in 198 patients.
Koktekir E; Ceylan D; Tatarli N; Karabagli H; Recber F; Akdemir G
Spine J; 2014 Aug; 14(8):1702-8. PubMed ID: 24704680
[TBL] [Abstract][Full Text] [Related]
35. Benefit and accuracy of intraoperative 3D-imaging after pedicle screw placement: a prospective study in stabilizing thoracolumbar fractures.
Beck M; Mittlmeier T; Gierer P; Harms C; Gradl G
Eur Spine J; 2009 Oct; 18(10):1469-77. PubMed ID: 19513764
[TBL] [Abstract][Full Text] [Related]
36. Accuracy of patient-specific template-guided vs. free-hand fluoroscopically controlled pedicle screw placement in the thoracic and lumbar spine: a randomized cadaveric study.
Farshad M; Betz M; Farshad-Amacker NA; Moser M
Eur Spine J; 2017 Mar; 26(3):738-749. PubMed ID: 27502497
[TBL] [Abstract][Full Text] [Related]
37. Thoracolumbar instrumentation with CT-guided navigation (O-arm) in 270 consecutive patients: accuracy rates and lessons learned.
Rivkin MA; Yocom SS
Neurosurg Focus; 2014 Mar; 36(3):E7. PubMed ID: 24580008
[TBL] [Abstract][Full Text] [Related]
38. Does Augmented Reality Navigation Increase Pedicle Screw Density Compared to Free-Hand Technique in Deformity Surgery? Single Surgeon Case Series of 44 Patients.
Edström E; Burström G; Persson O; Charalampidis A; Nachabe R; Gerdhem P; Elmi-Terander A
Spine (Phila Pa 1976); 2020 Sep; 45(17):E1085-E1090. PubMed ID: 32355149
[TBL] [Abstract][Full Text] [Related]
39. Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: a prospective randomized comparison to conventional freehand screw implantation.
Ringel F; Stüer C; Reinke A; Preuss A; Behr M; Auer F; Stoffel M; Meyer B
Spine (Phila Pa 1976); 2012 Apr; 37(8):E496-501. PubMed ID: 22310097
[TBL] [Abstract][Full Text] [Related]
40. Using the freehand pedicle screw placement technique in adolescent idiopathic scoliosis surgery: what is the incidence of neurological symptoms secondary to misplaced screws?
Dede O; Ward WT; Bosch P; Bowles AJ; Roach JW
Spine (Phila Pa 1976); 2014 Feb; 39(4):286-90. PubMed ID: 24553446
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]