425 related articles for article (PubMed ID: 28958735)
1. An integrated system for clinical treatment verification of HDR prostate brachytherapy combining source tracking with pretreatment imaging.
Smith RL; Hanlon M; Panettieri V; Millar JL; Matheson B; Haworth A; Franich RD
Brachytherapy; 2018; 17(1):111-121. PubMed ID: 28958735
[TBL] [Abstract][Full Text] [Related]
2. A method for verification of treatment delivery in HDR prostate brachytherapy using a flat panel detector for both imaging and source tracking.
Smith RL; Haworth A; Panettieri V; Millar JL; Franich RD
Med Phys; 2016 May; 43(5):2435. PubMed ID: 27147354
[TBL] [Abstract][Full Text] [Related]
3. The evaluation of a 2D diode array in "magic phantom" for use in high dose rate brachytherapy pretreatment quality assurance.
Espinoza A; Petasecca M; Fuduli I; Howie A; Bucci J; Corde S; Jackson M; Lerch ML; Rosenfeld AB
Med Phys; 2015 Feb; 42(2):663-673. PubMed ID: 28102606
[TBL] [Abstract][Full Text] [Related]
4. Source position verification and dosimetry in HDR brachytherapy using an EPID.
Smith RL; Taylor ML; McDermott LN; Haworth A; Millar JL; Franich RD
Med Phys; 2013 Nov; 40(11):111706. PubMed ID: 24320414
[TBL] [Abstract][Full Text] [Related]
5. Online correction of catheter movement using CT in high-dose-rate prostate brachytherapy.
Huang Y; Miller B; Doemer A; Babij D; Kumar S; Frontera R; Nurushev T; Chetty IJ; Aref I
Brachytherapy; 2013; 12(3):260-6. PubMed ID: 23453680
[TBL] [Abstract][Full Text] [Related]
6. 3D catheter reconstruction in HDR prostate brachytherapy for pre-treatment verification using a flat panel detector.
Smith RL; Haworth A; Panettieri V; Millar JL; Franich RD
Phys Med; 2017 Jul; 39():121-131. PubMed ID: 28625472
[TBL] [Abstract][Full Text] [Related]
7. Real-time electromagnetic tracking-based treatment platform for high-dose-rate prostate brachytherapy: Clinical workflows and end-to-end validation.
Beaulieu L; Racine E; Han DY; Vigneault E; Hsu IC; Cunha JAM
Brachytherapy; 2018; 17(1):103-110. PubMed ID: 28576644
[TBL] [Abstract][Full Text] [Related]
8. Derivation of in vivo source tracking error thresholds for TRUS-based HDR prostate brachytherapy through simulation of source positioning errors.
Poder J; Carrara M; Howie A; Cutajar D; Bucci J; Rosenfeld A
Brachytherapy; 2019; 18(5):711-719. PubMed ID: 31175015
[TBL] [Abstract][Full Text] [Related]
9. A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy.
Therriault-Proulx F; Briere TM; Mourtada F; Aubin S; Beddar S; Beaulieu L
Med Phys; 2011 May; 38(5):2542-51. PubMed ID: 21776789
[TBL] [Abstract][Full Text] [Related]
10. A Monte Carlo study on the feasibility of real-time in vivo source tracking during ultrasound based HDR prostate brachytherapy treatments.
Poder J; Cutajar D; Guatelli S; Petasecca M; Howie A; Bucci J; Carrara M; Rosenfeld A
Phys Med; 2019 Mar; 59():30-36. PubMed ID: 30928063
[TBL] [Abstract][Full Text] [Related]
11. BrachyView, a novel inbody imaging system for HDR prostate brachytherapy: design and Monte Carlo feasibility study.
Safavi-Naeini M; Han Z; Cutajar D; Guatelli S; Petasecca M; Lerch ML; Franklin DR; Jakubek J; Pospisil S; Bucci J; Zaider M; Rosenfeld AB
Med Phys; 2013 Jul; 40(7):071715. PubMed ID: 23822419
[TBL] [Abstract][Full Text] [Related]
12. Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy.
Poulin E; Fekete CA; Létourneau M; Fenster A; Pouliot J; Beaulieu L
Med Phys; 2013 Nov; 40(11):111724. PubMed ID: 24320432
[TBL] [Abstract][Full Text] [Related]
13. The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance.
Espinoza A; Petasecca M; Fuduli I; Howie A; Bucci J; Corde S; Jackson M; Lerch ML; Rosenfelda AB
Med Phys; 2015 Feb; 42(2):663-73. PubMed ID: 25771556
[TBL] [Abstract][Full Text] [Related]
14. The effect of catheter displacement and anatomical variations on the dose distribution in MRI-guided focal HDR brachytherapy for prostate cancer.
Maenhout M; van der Voort van Zyp JRN; Borot de Battisti M; Peters M; van Vulpen M; van den Bosch M; Moerland MA
Brachytherapy; 2018; 17(1):68-77. PubMed ID: 28579419
[TBL] [Abstract][Full Text] [Related]
15. Online pretreatment verification of high-dose rate brachytherapy using an imaging panel.
Fonseca GP; Podesta M; Bellezzo M; Van den Bosch MR; Lutgens L; Vanneste BGL; Voncken R; Van Limbergen EJ; Reniers B; Verhaegen F
Phys Med Biol; 2017 Jul; 62(13):5440-5461. PubMed ID: 28609297
[TBL] [Abstract][Full Text] [Related]
16. The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance.
Espinoza A; Beeksma B; Petasecca M; Fuduli I; Porumb C; Cutajar D; Corde S; Jackson M; Lerch ML; Rosenfeld AB
Med Phys; 2013 Nov; 40(11):111702. PubMed ID: 24320410
[TBL] [Abstract][Full Text] [Related]
17. Electromagnetic tracking for catheter reconstruction in ultrasound-guided high-dose-rate brachytherapy of the prostate.
Bharat S; Kung C; Dehghan E; Ravi A; Venugopal N; Bonillas A; Stanton D; Kruecker J
Brachytherapy; 2014; 13(6):640-50. PubMed ID: 24929641
[TBL] [Abstract][Full Text] [Related]
18. 3D source tracking and error detection in HDR using two independent scintillator dosimetry systems.
Linares Rosales HM; Johansen JG; Kertzscher G; Tanderup K; Beaulieu L; Beddar S
Med Phys; 2021 May; 48(5):2095-2107. PubMed ID: 33222208
[TBL] [Abstract][Full Text] [Related]
19. Electromagnetic tracking (EMT) technology for improved treatment quality assurance in interstitial brachytherapy.
Kellermeier M; Herbolzheimer J; Kreppner S; Lotter M; Strnad V; Bert C
J Appl Clin Med Phys; 2017 Jan; 18(1):211-222. PubMed ID: 28291934
[TBL] [Abstract][Full Text] [Related]
20. Accuracy of an in vivo dosimetry-based source tracking method for afterloading brachytherapy - A phantom study.
Jørgensen EB; Kertzscher G; Buus S; Bentzen L; Hokland SB; Rylander S; Tanderup K; Johansen JG
Med Phys; 2021 May; 48(5):2614-2623. PubMed ID: 33655555
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]