140 related articles for article (PubMed ID: 28959090)
1. Instrumented Urethral Catheter and Its Ex Vivo Validation in a Sheep Urethra.
Ahmadi M; Rajamani R; Timm G; Sezen S
Meas Sci Technol; 2017 Mar; 28(3):. PubMed ID: 28959090
[TBL] [Abstract][Full Text] [Related]
2. Flexible Distributed Pressure Sensing Strip for a Urethral Catheter.
Ahmadi M; Rajamani R; Timm G; Sezen AS
J Microelectromech Syst; 2015 Dec; 24(6):1840-1847. PubMed ID: 27065719
[TBL] [Abstract][Full Text] [Related]
3. An Instrumented Urethral Catheter with a Distributed Array of Iontronic Force Sensors.
Zhang Y; Ahmadi M; Timm G; Sezen S; Rajamani R
Ann Biomed Eng; 2021 Jan; 49(1):149-161. PubMed ID: 32377979
[TBL] [Abstract][Full Text] [Related]
4. Distributed pressure sensors for a urethral catheter.
Ahmadi M; Rajamani R; Timm G; Sezen AS
Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():7610-3. PubMed ID: 26738054
[TBL] [Abstract][Full Text] [Related]
5. A Super-Capacitive Pressure Sensor for a Urethral Catheter.
Ahmadi M; Zhang Y; Rajamani R; Timm G; Sezen AS
Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():1-3. PubMed ID: 30440292
[TBL] [Abstract][Full Text] [Related]
6. Artificial urinary sphincter cuffs and safe instrument/catheter passage guidelines.
Otis-Chapados S; Kim J; Radomski SB
Neurourol Urodyn; 2022 Nov; 41(8):1764-1769. PubMed ID: 35971797
[TBL] [Abstract][Full Text] [Related]
7. [Recommendations for the urodynamic examination in the investigation of non-neurological female urinary incontinence].
Hermieu JF;
Prog Urol; 2007 Nov; 17(6 Suppl 2):1264-84. PubMed ID: 18214138
[TBL] [Abstract][Full Text] [Related]
8. Performance analysis of the T-DOC® air-charged catheters: An alternate technology for urodynamics.
Couri BM; Bitzos S; Bhardwaj D; Lockhart E; Yue A; Goping I
Neurourol Urodyn; 2018 Feb; 37(2):619-625. PubMed ID: 28715147
[TBL] [Abstract][Full Text] [Related]
9. Measurement of dynamic urethral pressures with a high-resolution manometry system in continent and incontinent women.
Kirby AC; Tan-Kim J; Nager CW
Female Pelvic Med Reconstr Surg; 2015; 21(2):106-10. PubMed ID: 25185595
[TBL] [Abstract][Full Text] [Related]
10. Signal processing in urodynamics: towards high definition urethral pressure profilometry.
Klünder M; Sawodny O; Amend B; Ederer M; Kelp A; Sievert KD; Stenzl A; Feuer R
Biomed Eng Online; 2016 Mar; 15():31. PubMed ID: 27000558
[TBL] [Abstract][Full Text] [Related]
11. Safer urethral catheters: how study of catheter balloon pressure and force can guide design.
Wu AK; Blaschko SD; Garcia M; McAninch JW; Aaronson DS
BJU Int; 2012 Apr; 109(7):1110-4. PubMed ID: 21871052
[TBL] [Abstract][Full Text] [Related]
12. Intraurethral catheter placement does not change the external circumferential measurement of the urethra during AUS placement: A prospective observational trial.
Boysen WR; Inouye BM; Kowalik U; Madden-Fuentes RJ; Kahokehr AA; Peterson AC
Neurourol Urodyn; 2020 Jun; 39(5):1538-1542. PubMed ID: 32449543
[TBL] [Abstract][Full Text] [Related]
13. High definition urethral pressure profilometry: Evaluating a novel microtip catheter.
Klünder M; Amend B; Vaegler M; Kelp A; Feuer R; Sievert KD; Stenzl A; Sawodny O; Ederer M
Neurourol Urodyn; 2016 Nov; 35(8):888-894. PubMed ID: 26207994
[TBL] [Abstract][Full Text] [Related]
14. Additional value of triple-sensor urethral catheter in demonstrating urethral pressure variations during filling cystometry.
Kummeling MT; Bovelander E; van Uhm JI; van Koeveringe GA; Elzevier HW; Putter H; Groenendijk PM
Neurourol Urodyn; 2019 Nov; 38(8):2368-2373. PubMed ID: 31486148
[TBL] [Abstract][Full Text] [Related]
15. Initial urethral pressure increase during stress episodes in genuine stress incontinent women.
Thind P; Lose G; Colstrup H
Br J Urol; 1992 Feb; 69(2):137-40. PubMed ID: 1537023
[TBL] [Abstract][Full Text] [Related]
16. Relative urethral leakage pressure versus maximum urethral closure pressure. The reliability of the measurement of urethral competence with the new tube-foil sleeve catheter in patients.
van Venrooij GE; Blok C; van Riel MP; Coolsaet BL
J Urol; 1985 Sep; 134(3):592-5. PubMed ID: 4040981
[TBL] [Abstract][Full Text] [Related]
17. Valsalva leak point pressure to determine internal sphincter deficiency in stress urinary incontinence.
Rodrigues P; Afonso Y; Hering FO; Campagnari JC; Azoubel A
Urol Int; 2006; 76(2):154-8. PubMed ID: 16493218
[TBL] [Abstract][Full Text] [Related]
18. The risk of intra-urethral Foley catheter balloon inflation in spinal cord-injured patients: Lessons learned from a retrospective case series.
Subramanian V; Soni BM; Hughes PL; Singh G; Oo T
Patient Saf Surg; 2016; 10():14. PubMed ID: 27213016
[TBL] [Abstract][Full Text] [Related]
19. [Study of directional differences on static and stress urethral pressure profiles of female urethra].
Masuda H; Yamada T; Nagamatsu H; Nagahama K; Kawakami S; Watanabe T; Negishi T; Morita T
Nihon Hinyokika Gakkai Zasshi; 1997 Jan; 88(1):40-5. PubMed ID: 9038051
[TBL] [Abstract][Full Text] [Related]
20. Development of a more clinically relevant bladder and urethral model for catheter testing.
Gammie A; Holmes R; Chen HY; Conn A; Morris N; Drake MJ
J Med Eng Technol; 2021 Apr; 45(3):237-244. PubMed ID: 33750247
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]