These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 28964222)

  • 1. Existing methods for improving the accuracy of digital-to-analog converters.
    Eielsen AA; Fleming AJ
    Rev Sci Instrum; 2017 Sep; 88(9):094702. PubMed ID: 28964222
    [TBL] [Abstract][Full Text] [Related]  

  • 2. An adaptive calibration technique of timing skew mismatch in time-interleaved analog-to-digital converters.
    Gao J; Ye P; Zeng H; Song J; Wei W; Yang K
    Rev Sci Instrum; 2019 Feb; 90(2):025102. PubMed ID: 30831763
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Standards for Waveform Metrology Based on Digital Techniques.
    Bell BA
    J Res Natl Inst Stand Technol; 1990; 95(4):377-405. PubMed ID: 28179783
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Joint Error Estimation and Calibration Method of Memory Nonlinear Mismatch for a Four-Channel 16-Bit TIADC System.
    Zhang J; Zhou Y; Zhao J; Niu G; Luo X
    Sensors (Basel); 2022 Mar; 22(7):. PubMed ID: 35408042
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Real-time self-adaptive calibration method for high speed acquisition system.
    Zeng H; Ye P; Wei W; Guo L; Pan H; Yang K
    Rev Sci Instrum; 2019 Jan; 90(1):015118. PubMed ID: 30709185
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analysis of the resolution-bandwidth-noise trade-off in wavelength-based photonic analog-to-digital converters.
    Stigwall J; Galt S
    Appl Opt; 2006 Jun; 45(18):4310-8. PubMed ID: 16778940
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noise characterization of analog to digital converters for amplitude and phase noise measurements.
    Cárdenas-Olaya AC; Rubiola E; Friedt JM; Bourgeois PY; Ortolano M; Micalizio S; Calosso CE
    Rev Sci Instrum; 2017 Jun; 88(6):065108. PubMed ID: 28667980
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Histogram-Based Calibration Method for Pipeline ADCs.
    Son H; Jang J; Kim H; Kang S
    PLoS One; 2015; 10(6):e0129736. PubMed ID: 26070196
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A 1.15 μW 200 kS/s 10-b Monotonic SAR ADC Using Dual On-Chip Calibrations and Accuracy Enhancement Techniques.
    Lee JH; Park D; Cho W; Phan HN; Nguyen CL; Lee JW
    Sensors (Basel); 2018 Oct; 18(10):. PubMed ID: 30332815
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Identification and correction of analog-to-digital-converter nonlinearities and their implications for differential absorption lidar measurements.
    Langford AO
    Appl Opt; 1995 Dec; 34(36):8330-40. PubMed ID: 21068953
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Estimation of channel mismatches in time-interleaved analog-to-digital converters based on fractional delay and sine curve fitting.
    Guo L; Tian S; Jiang J
    Rev Sci Instrum; 2015 Mar; 86(3):034713. PubMed ID: 25832264
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Noise-shaping gradient descent-based online adaptation algorithms for digital calibration of analog circuits.
    Chakrabartty S; Shaga RK; Aono K
    IEEE Trans Neural Netw Learn Syst; 2013 Apr; 24(4):554-65. PubMed ID: 24808377
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A look-up-table digital predistortion technique for high-voltage power amplifiers in ultrasonic applications.
    Gao Z; Gui P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Jul; 59(7):1550-7. PubMed ID: 22828849
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mismatch error correction for time interleaved analog-to-digital converter over a wide frequency range.
    Jiang Z; Zhao L; Gao X; Dong R; Liu J; An Q
    Rev Sci Instrum; 2018 Aug; 89(8):084709. PubMed ID: 30184686
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A fast Fourier transform based method to estimate frequency response mismatches in time interleaved systems.
    Yang K; Pan Z; Ye P; Shi J; Zhao Y; Meng J
    Rev Sci Instrum; 2021 May; 92(5):054709. PubMed ID: 34243323
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Smart Capture Modules for Direct Sensor-to-FPGA Interfaces.
    Oballe-Peinado Ó; Vidal-Verdú F; Sánchez-Durán JA; Castellanos-Ramos J; Hidalgo-López JA
    Sensors (Basel); 2015 Dec; 15(12):31762-80. PubMed ID: 26694403
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Oversampling data acquisition to improve resolution of digitized signals.
    Pagnacco G; Oggero E; Morr DR; Berme N
    Biomed Sci Instrum; 1997; 34():137-42. PubMed ID: 9603027
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Front-End Readout as an Encoder IC for Magneto-Resistive Linear Scale Sensors.
    Tran TH; Chao PC; Chien PC
    Sensors (Basel); 2016 Sep; 16(9):. PubMed ID: 27598165
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An accurate projector calibration method based on polynomial distortion representation.
    Liu M; Sun C; Huang S; Zhang Z
    Sensors (Basel); 2015 Oct; 15(10):26567-82. PubMed ID: 26492247
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fast and robust control of nanopositioning systems: Performance limits enabled by field programmable analog arrays.
    Baranwal M; Gorugantu RS; Salapaka SM
    Rev Sci Instrum; 2015 Aug; 86(8):085004. PubMed ID: 26329226
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.