These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
93 related articles for article (PubMed ID: 28964594)
1. Deconvolution of Pommé S; Marouli M; Paepen J; Marković N; Pöllänen R Appl Radiat Isot; 2018 Apr; 134():233-239. PubMed ID: 28964594 [TBL] [Abstract][Full Text] [Related]
2. Conversion electron spectroscopy of the 59.54 keV transition in Pommé S; Paepen J; Marouli M Appl Radiat Isot; 2019 Nov; 153():108848. PubMed ID: 31442878 [TBL] [Abstract][Full Text] [Related]
3. Conversion electron spectrometry of Pu isotopes with a silicon drift detector. Pommé S; Paepen J; Peräjärvi K; Turunen J; Pöllänen R Appl Radiat Isot; 2016 Mar; 109():183-188. PubMed ID: 26651177 [TBL] [Abstract][Full Text] [Related]
4. Analysis of a neutron-induced conversion electron spectrum of gadolinium. Pommé S; Veale MC; Pooley DE; Van Assche F; Falksohn F; Collins SM Appl Radiat Isot; 2023 Jul; 197():110828. PubMed ID: 37126950 [TBL] [Abstract][Full Text] [Related]
5. Spectral distribution of particle fluence in small field detectors and its implication on small field dosimetry. Benmakhlouf H; Andreo P Med Phys; 2017 Feb; 44(2):713-724. PubMed ID: 28032369 [TBL] [Abstract][Full Text] [Related]
6. Simulation of Radiation Damage for Silicon Drift Detector. Liu Y; Zhu T; Yao J; Ouyang X Sensors (Basel); 2019 Apr; 19(8):. PubMed ID: 31013874 [TBL] [Abstract][Full Text] [Related]
7. Spectral perturbations from silicon diode detector encapsulation and shielding in photon fields. Eklund K; Ahnesjö A Med Phys; 2010 Nov; 37(11):6055-60. PubMed ID: 21158317 [TBL] [Abstract][Full Text] [Related]
8. Determination of the uranium enrichment without calibration standards using a 500 mm Meleshenkovskii I; Pauly N; Labeau PE Appl Radiat Isot; 2019 Jun; 148():277-289. PubMed ID: 31030087 [TBL] [Abstract][Full Text] [Related]
9. Design and 3D Electrical Simulations for a Controllable Equal-Gap Large-Area Silicon Drift Detector. Zhao J; Long T; Wang M; Liu M; Tang M; Li Z Sensors (Basel); 2024 Feb; 24(5):. PubMed ID: 38474924 [TBL] [Abstract][Full Text] [Related]
10. On determining dose rate constants spectroscopically. Rodriguez M; Rogers DW Med Phys; 2013 Jan; 40(1):011713. PubMed ID: 23298083 [TBL] [Abstract][Full Text] [Related]
11. The Effects of Different Anode Positions on the Electrical Properties of Square-Silicon Drift Detector. Luo W; Wang L; Jia R; Tao K; Wang B; Ouyang X; Li X Micromachines (Basel); 2022 Sep; 13(9):. PubMed ID: 36144119 [TBL] [Abstract][Full Text] [Related]
12. Determination of (235)U, (239)Pu, (240)Pu, and (241)Am in a nuclear bomb particle using a position-sensitive α-γ coincidence technique. Peräjärvi KA; Ihantola S; Pöllänen RC; Toivonen HI; Turunen JA Environ Sci Technol; 2011 Feb; 45(4):1528-33. PubMed ID: 21247104 [TBL] [Abstract][Full Text] [Related]
13. Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography. Hoerner MR; Stepusin EJ; Hyer DE; Hintenlang DE Med Phys; 2015 Mar; 42(3):1268-79. PubMed ID: 25735282 [TBL] [Abstract][Full Text] [Related]
14. Light output measurements and computational models of microcolumnar CsI scintillators for x-ray imaging. Nillius P; Klamra W; Sibczynski P; Sharma D; Danielsson M; Badano A Med Phys; 2015 Feb; 42(2):600-605. PubMed ID: 28102604 [TBL] [Abstract][Full Text] [Related]
15. Quantitative Electron-Excited X-Ray Microanalysis of Borides, Carbides, Nitrides, Oxides, and Fluorides with Scanning Electron Microscopy/Silicon Drift Detector Energy-Dispersive Spectrometry (SEM/SDD-EDS) and NIST DTSA-II. Newbury DE; Ritchie NW Microsc Microanal; 2015 Oct; 21(5):1327-40. PubMed ID: 26365439 [TBL] [Abstract][Full Text] [Related]
16. Arctic Ocean sea ice drift origin derived from artificial radionuclides. Cámara-Mor P; Masqué P; Garcia-Orellana J; Cochran JK; Mas JL; Chamizo E; Hanfland C Sci Total Environ; 2010 Jul; 408(16):3349-58. PubMed ID: 20434194 [TBL] [Abstract][Full Text] [Related]
17. Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: a PENELOPE Monte Carlo study. Benmakhlouf H; Sempau J; Andreo P Med Phys; 2014 Apr; 41(4):041711. PubMed ID: 24694131 [TBL] [Abstract][Full Text] [Related]
18. Correction of coincidence summing effects for add-back mode measurements with a 4π clover detector using experimental total efficiency. Yamashita T; Kamada H; Kojima Y; Shibata M Appl Radiat Isot; 2018 May; 135():131-134. PubMed ID: 29413827 [TBL] [Abstract][Full Text] [Related]
19. A (238)Pu irradiator for exposure of cultured cells with alpha-radiation: construction, calibration and dosimetry. Tisnek N; Kalanxhi E; Serkland CW; Iversen J; Belyakov OV; Dahle J Appl Radiat Isot; 2009 Nov; 67(11):1998-2002. PubMed ID: 19716308 [TBL] [Abstract][Full Text] [Related]
20. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV). Tedgren AC; Hedman A; Grindborg JE; Carlsson GA Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]