269 related articles for article (PubMed ID: 28970518)
1. Three-screw versus two-screw fixation of distal fragment in fifth metacarpal neck fractures stabilized with locking plate. Zhu H; Bao B; Zheng X Sci Rep; 2017 Oct; 7(1):12516. PubMed ID: 28970518 [TBL] [Abstract][Full Text] [Related]
2. Locking Plate Alone versus in Combination with Two Crossed Kirschner Wires for Fifth Metacarpal Neck Fracture. Zhu H; Xu Z; Wei H; Zheng X Sci Rep; 2017 Apr; 7():46109. PubMed ID: 28378776 [TBL] [Abstract][Full Text] [Related]
3. Antegrade intramedullary pinning versus retrograde intramedullary pinning for displaced fifth metacarpal neck fractures. Kim JK; Kim DJ Clin Orthop Relat Res; 2015 May; 473(5):1747-54. PubMed ID: 25502343 [TBL] [Abstract][Full Text] [Related]
4. Biomechanical analysis of locking plates for fixation of metacarpal shaft fractures: A finite element analysis. Zhang JF; Li Y; Huo YX; Yan M; Liang SL; Wang L; Wang BC Orthop Traumatol Surg Res; 2022 Dec; 108(8):103340. PubMed ID: 35643362 [TBL] [Abstract][Full Text] [Related]
5. [Internal fixation of radial shaft fractures: Anatomical and biomechanical principles]. Bartoníček J; Naňka O; Tuček M Rozhl Chir; 2015 Oct; 94(10):425-36. PubMed ID: 26556020 [TBL] [Abstract][Full Text] [Related]
6. Comparison of Dorsal Plate Fixation Versus Intramedullary Headless Screw Fixation of Unstable Metacarpal Shaft Fractures: A Biomechanical Study. Melamed E; Hinds RM; Gottschalk MB; Kennedy OD; Capo JT Hand (N Y); 2016 Dec; 11(4):421-426. PubMed ID: 28149208 [No Abstract] [Full Text] [Related]
8. Comparison of a standard locking screw versus a double-threaded cortical compression screw for fixation of die-punch fragments in distal radius fractures with volar plating. Muccioli C; Hidalgo Diaz JJ; Pizza C; Gouzou S; Facca S; Liverneaux P Hand Surg Rehabil; 2020 Feb; 39(1):30-35. PubMed ID: 31734295 [TBL] [Abstract][Full Text] [Related]
9. Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture. Shanmugam R; Jian CYCCS; Haseeb A; Aik S J Orthop Surg (Hong Kong); 2018; 26(3):2309499018802511. PubMed ID: 30270746 [TBL] [Abstract][Full Text] [Related]
10. Comparison of treatment of oblique and spiral metacarpal and phalangeal fractures with mini plate plus screw or screw only. Başar H; Başar B; Başçı O; Topkar OM; Erol B; Tetik C Arch Orthop Trauma Surg; 2015 Apr; 135(4):499-504. PubMed ID: 25682110 [TBL] [Abstract][Full Text] [Related]
11. Comparison of the fixation ability between lag screw and bone plate for oblique metacarpal shaft fracture. Chiu YC; Ho TY; Hsu CE; Ting YN; Tsai MT; Hsu JT J Orthop Surg Res; 2022 Feb; 17(1):72. PubMed ID: 35123532 [TBL] [Abstract][Full Text] [Related]
12. [Multidirectional screw fixation in the treatment of distal radius fractures using angle-stable plates]. Vlček M; Landor I; Višňa P; Vavřík P; Sindelářová J; Sosna A Acta Chir Orthop Traumatol Cech; 2011; 78(1):27-33. PubMed ID: 21375962 [TBL] [Abstract][Full Text] [Related]
13. A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures. Wolf JC; Weil WM; Hanel DP; Trumble TE J Hand Surg Am; 2006 Dec; 31(10):1578-86. PubMed ID: 17145376 [TBL] [Abstract][Full Text] [Related]
14. The curative effect analysis of a modified Kirschner wires and locking plate internal fixation method for the fifth metacarpal neck fracture. Gu S; Zhou L; Huang Y; Xie R J Orthop Surg Res; 2021 Aug; 16(1):491. PubMed ID: 34384465 [TBL] [Abstract][Full Text] [Related]
15. Biomechanical study on fixation methods for horizontal oblique metacarpal shaft fractures. Chiu YC; Hsu CE; Ho TY; Ting YN; Tsai MT; Hsu JT J Orthop Surg Res; 2022 Aug; 17(1):374. PubMed ID: 35922799 [TBL] [Abstract][Full Text] [Related]
16. Volar fixed-angle plating of distal radius fractures: screws versus pegs--a biomechanical study in a cadaveric model. Mehling I; Klitscher D; Mehling AP; Nowak TE; Sternstein W; Rommens PM; Müller LP J Orthop Trauma; 2012 Jul; 26(7):395-401. PubMed ID: 22011636 [TBL] [Abstract][Full Text] [Related]
17. Metacarpal Position and Lunate Facet Screw Fixation in Dorsal Wrist-Spanning Bridge Plates for Intra-Articular Distal Radial Fracture: A Biomechanical Analysis. Guerrero EM; Lauder A; Federer AE; Glisson R; Richard MJ; Ruch DS J Bone Joint Surg Am; 2020 Mar; 102(5):397-403. PubMed ID: 31904607 [TBL] [Abstract][Full Text] [Related]
18. Extraarticular hand fractures in adults: a review of new developments. Freeland AE; Orbay JL Clin Orthop Relat Res; 2006 Apr; 445():133-45. PubMed ID: 16505726 [TBL] [Abstract][Full Text] [Related]
19. Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study. Mehling I; Müller LP; Delinsky K; Mehler D; Burkhart KJ; Rommens PM J Hand Surg Am; 2010 Jun; 35(6):885-91. PubMed ID: 20513572 [TBL] [Abstract][Full Text] [Related]
20. Headless Screw Fixation of Metacarpal Neck Fractures: A Mechanical Comparative Analysis. Jones CM; Padegimas EM; Weikert N; Greulich S; Ilyas AM; Siegler S Hand (N Y); 2019 Mar; 14(2):187-192. PubMed ID: 28933187 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]