BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

193 related articles for article (PubMed ID: 28971694)

  • 21. Influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study.
    Sakai R; Uchino M; Yoneo T; Ohtaki Y; Minehara H; Matsuura T; Gomi T; Ujihira M
    J Orthop Surg Res; 2017 Feb; 12(1):34. PubMed ID: 28228100
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Fibular fixation as an adjuvant to tibial intramedullary nailing in the treatment of combined distal third tibia and fibula fractures: a biomechanical investigation.
    Morin PM; Reindl R; Harvey EJ; Beckman L; Steffen T
    Can J Surg; 2008 Feb; 51(1):45-50. PubMed ID: 18248705
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Unstable Ankle Fracture Fixation Using Locked Fibular Intramedullary Nail in High-Risk Patients.
    Dabash S; Eisenstein ED; Potter E; Kusnezov N; Thabet AM; Abdelgawad AA
    J Foot Ankle Surg; 2019 Mar; 58(2):357-362. PubMed ID: 30612876
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Biomechanical Evaluation of Plate Versus Lag Screw Only Fixation of Distal Fibula Fractures.
    Misaghi A; Doan J; Bastrom T; Pennock AT
    J Foot Ankle Surg; 2015; 54(5):896-9. PubMed ID: 25990534
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Retrograde intramedullary nails with distal screws locked to the nail have higher fatigue strength than locking plates in the treatment of supracondylar femoral fractures: A cadaver-based laboratory investigation.
    Pekmezci M; McDonald E; Buckley J; Kandemir U
    Bone Joint J; 2014 Jan; 96-B(1):114-21. PubMed ID: 24395321
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Intramedullary screw fixation of lateral malleolus fractures.
    Bankston AB; Anderson LD; Nimityongskul P
    Foot Ankle Int; 1994 Nov; 15(11):599-607. PubMed ID: 7849975
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [A biomechanical study on internal and external fixation devices for treatment of humeral shaft fracture].
    Niu X; Huang F; Cen S; Qin T; Wang R; Shang Z; Liu A; Zheng H
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 May; 22(5):516-9. PubMed ID: 18630425
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An augmented fixation method for distal fibular fractures in elderly patients: a biomechanical evaluation.
    Dunn WR; Easley ME; Parks BG; Trnka HJ; Schon LC
    Foot Ankle Int; 2004 Mar; 25(3):128-31. PubMed ID: 15006332
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The role of intramedullary fixation in ankle fractures - A systematic review.
    Jordan RW; Chapman AWP; Buchanan D; Makrides P
    Foot Ankle Surg; 2018 Feb; 24(1):1-10. PubMed ID: 29413767
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biomechanical Analysis of Stability of Posterior Antiglide Plating in Osteoporotic Pronation Abduction Ankle Fracture Model With Posterior Tibial Fragment.
    Hartwich K; Lorente Gomez A; Pyrc J; Gut R; Rammelt S; Grass R
    Foot Ankle Int; 2017 Jan; 38(1):58-65. PubMed ID: 27672062
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Two-part surgical neck fractures of the proximal part of the humerus. A biomechanical evaluation of two fixation techniques.
    Edwards SL; Wilson NA; Zhang LQ; Flores S; Merk BR
    J Bone Joint Surg Am; 2006 Oct; 88(10):2258-64. PubMed ID: 17015605
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Fracture Fixation Strength in Metacarpal Plating Versus Intramedullary Nailing Using a 3-Point Bending Model: A Cadaveric, Biomechanical Study.
    Beaumont CM; Beason DP; McKeon KE
    J Hand Surg Am; 2024 Jan; 49(1):57.e1-57.e6. PubMed ID: 35803782
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Primary stability of an intramedullary calcaneal nail and an angular stable calcaneal plate in a biomechanical testing model of intraarticular calcaneal fracture.
    Goldzak M; Simon P; Mittlmeier T; Chaussemier M; Chiergatti R
    Injury; 2014 Jan; 45 Suppl 1():S49-53. PubMed ID: 24219899
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Lateral malleolar fractures Weber Type A and B: does percutaneous intramedullary screw confer a solid alternative to the traditional neutralization plate?
    Zawam SH; Mabrouk MG; El-Desouky MA
    Int Orthop; 2022 Sep; 46(9):2127-2134. PubMed ID: 35575804
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Fixation of distal fibular fractures: A biomechanical study of plate fixation techniques.
    Marvan J; Horak Z; Vilimek M; Horny L; Kachlik D; Baca V
    Acta Bioeng Biomech; 2017; 19(1):33-39. PubMed ID: 28552927
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Fibula Fracture: Plate versus Nail Fixation.
    Bäcker HC; Vosseller JT
    Clin Orthop Surg; 2020 Dec; 12(4):529-534. PubMed ID: 33274031
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Internal fixation of type-C distal femoral fractures in osteoporotic bone.
    Wähnert D; Hoffmeier KL; von Oldenburg G; Fröber R; Hofmann GO; Mückley T
    J Bone Joint Surg Am; 2010 Jun; 92(6):1442-52. PubMed ID: 20516320
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Biomechanical comparison of a 2 and 3 proximal screw-configured antegrade piriformis intramedullary nail with a trochanteric reconstruction nail in an unstable subtrochanteric fracture model.
    Fissel B; Moed BR; Bledsoe JG
    J Orthop Trauma; 2008; 22(5):337-41. PubMed ID: 18448988
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of augmentation methods for internal fixation of osteoporotic ankle fractures.
    Panchbhavi VK; Vallurupalli S; Morris R
    Foot Ankle Int; 2009 Jul; 30(7):696-703. PubMed ID: 19589319
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [A comparisive study between intramedullary interlocking nail and plate-screw fixation in the treatment of tibial shaft fractures].
    Huang P; Tang PF; Yao Q; Liang YT; Tao S; Zhang Q; Guo YZ; Liang XD; Wang Y
    Zhongguo Gu Shang; 2008 Apr; 21(4):261-3. PubMed ID: 19102183
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.