These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

100 related articles for article (PubMed ID: 28978561)

  • 1. Implementing a Reference Measurement System for C-Peptide: An Addendum.
    Little RR; Kinumi T; Connolly S; Kabytaev K
    Clin Chem; 2017 Dec; 63(12):1904-1905. PubMed ID: 28978561
    [No Abstract]   [Full Text] [Related]  

  • 2. Preparation, calibration and evaluation of the First International Standard for human C-peptide.
    Moore M; Dougall T; Ferguson J; Rigsby P; Burns C
    Clin Chem Lab Med; 2017 Jul; 55(8):1224-1233. PubMed ID: 28593916
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Standardization of C-peptide measurements.
    Little RR; Rohlfing CL; Tennill AL; Madsen RW; Polonsky KS; Myers GL; Greenbaum CJ; Palmer JP; Rogatsky E; Stein DT
    Clin Chem; 2008 Jun; 54(6):1023-6. PubMed ID: 18420730
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reference dosimetry on TomoTherapy: an addendum to the 1990 UK MV dosimetry code of practice.
    Thomas SJ; Aspradakis MM; Byrne JP; Chalmers G; Duane S; Rogers J; Thomas RA; Tudor GS; Twyman N;
    Phys Med Biol; 2014 Mar; 59(6):1339-52. PubMed ID: 24583900
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of the recommendations of the AAPM TG-51 and TG-51 addendum reference dosimetry protocols.
    McCaw TJ; Hwang MS; Jang SY; Huq MS
    J Appl Clin Med Phys; 2017 Jul; 18(4):140-143. PubMed ID: 28574211
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of SI-traceable C-peptide certified reference material NMIJ CRM 6901-a using isotope-dilution mass spectrometry-based amino acid analyses.
    Kinumi T; Goto M; Eyama S; Kato M; Kasama T; Takatsu A
    Anal Bioanal Chem; 2012 Jul; 404(1):13-21. PubMed ID: 22610603
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitative Amino Acid Analysis in Insulin and C-Peptide Assays.
    Taylor SW; Clarke NJ; McPhaul MJ
    Clin Chem; 2016 Aug; 62(8):1152-3. PubMed ID: 27306899
    [No Abstract]   [Full Text] [Related]  

  • 8. Reference intervals for C-peptide and insulin derived from a general adult Danish population.
    Larsen PB; Linneberg A; Hansen T; Friis-Hansen L
    Clin Biochem; 2017 May; 50(7-8):408-413. PubMed ID: 27989491
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of commercial ELISA and RIA for measuring porcine C-peptide: implications for research.
    Graham ML; Gresch SC; Hardy SK; Mutch LA; Janecek JL; Hegstad-Davies RL
    Xenotransplantation; 2015; 22(1):62-9. PubMed ID: 25291621
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of immunoassays for the measurement of insulin and C-peptide as indirect biomarkers of insulin misuse in sport: values in selected population of athletes.
    Abellan R; Ventura R; Palmi I; di Carlo S; di Giovannandrea R; Bellver M; Olive R; Pascual JA; Pacifici R; Segura J; Zuccaro P; Pichini S
    J Pharm Biomed Anal; 2009 Apr; 49(3):793-9. PubMed ID: 19181472
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cross-validation of commercial enzyme-linked immunosorbent assay and radioimmunoassay for porcine C-peptide concentration measurements in non-human primate serum.
    Gresch SC; Mutch LA; Janecek JL; Hegstad-Davies RL; Graham ML
    Xenotransplantation; 2017 Sep; 24(5):. PubMed ID: 28731212
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Identification and accurate quantification of structurally related peptide impurities in synthetic human C-peptide by liquid chromatography-high resolution mass spectrometry.
    Li M; Josephs RD; Daireaux A; Choteau T; Westwood S; Wielgosz RI; Li H
    Anal Bioanal Chem; 2018 Aug; 410(20):5059-5070. PubMed ID: 29862433
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Feasibility of standardization of serum C-peptide immunoassays with isotope-dilution liquid chromatography-tandem mass spectrometry.
    Cabaleiro DR; Stöckl D; Kaufman JM; Fiers T; Thienpont LM
    Clin Chem; 2006 Jun; 52(6):1193-6. PubMed ID: 16613996
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Six methods for the determination of C-peptide evaluated.
    Nauck MS; Nauck MA; Nauck MA; März W; Wieland H
    Clin Chem Lab Med; 1999 Jul; 37(7):745-51. PubMed ID: 10510733
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of an improved time-resolved fluoroimmunoassay for simultaneous quantification of C-peptide and insulin in human serum.
    Liu TC; Chen MJ; Ren ZQ; Hou JY; Lin GF; Wu YS
    Clin Biochem; 2014 Apr; 47(6):439-44. PubMed ID: 24463229
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical Utility and Cross-Reactivity of Insulin and C-Peptide Assays by the Lumipulse G1200 System.
    Oh J; Kim JH; Park HD
    Ann Lab Med; 2018 Nov; 38(6):530-537. PubMed ID: 30027696
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantitative analysis of urinary C-peptide by liquid chromatography-tandem mass spectrometry with a stable isotopically labelled internal standard.
    Fierens C; Thienpont LM; Stöckl D; Willekens E; De Leenheer AP
    J Chromatogr A; 2000 Oct; 896(1-2):275-8. PubMed ID: 11093662
    [TBL] [Abstract][Full Text] [Related]  

  • 18. C-peptide measurement: methods and clinical utility.
    Bonser AM; Garcia-Webb P
    Crit Rev Clin Lab Sci; 1984; 19(4):297-352. PubMed ID: 6373142
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of ionization chamber absorbed dose k(Q) factors in megavoltage photon beams.
    McEwen MR
    Med Phys; 2010 May; 37(5):2179-93. PubMed ID: 20527552
    [TBL] [Abstract][Full Text] [Related]  

  • 20. International comparison of C-peptide measurements.
    Wiedmeyer HM; Polonsky KS; Myers GL; Little RR; Greenbaum CJ; Goldstein DE; Palmer JP
    Clin Chem; 2007 Apr; 53(4):784-7. PubMed ID: 17332147
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.