These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 28980530)

  • 1. A novel technique to optimise the length of a linear accelerator treatment room maze without compromising radiation protection.
    Al-Affan IAM; Evans SC; Qutub M; Hugtenburg RP
    J Radiol Prot; 2018 Mar; 38(1):48-60. PubMed ID: 28980530
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes.
    Al-Affan IA; Hugtenburg RP; Bari DS; Al-Saleh WM; Piliero M; Evans S; Al-Hasan M; Al-Zughul B; Al-Kharouf S; Ghaith A
    Med Phys; 2015 Feb; 42(2):606-614. PubMed ID: 28102603
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes.
    Al-Affan IA; Hugtenburg RP; Bari DS; Al-Saleh WM; Piliero M; Evans S; Al-Hasan M; Al-Zughul B; Al-Kharouf S; Ghaith A
    Med Phys; 2015 Feb; 42(2):606-14. PubMed ID: 25771559
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Estimation of the dose at the maze entrance for x-rays from radiotherapy linear accelerators.
    Al-Affan IA
    Med Phys; 2000 Jan; 27(1):231-8. PubMed ID: 10659762
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of the photon spectrum of a therapeutic linear accelerator near the maze entrance: Comparison of Monte Carlo modeling and measurements using scintillation detectors corrected for pulse pile-up.
    Qutub MAZ; Hugtenburg RP; Al-Affan IAM
    Med Phys; 2020 Sep; 47(9):4522-4530. PubMed ID: 32469079
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The neutron dose equivalent evaluation and shielding at the maze entrance of a Varian Clinac 23EX treatment room.
    Wang X; Esquivel C; Nes E; Shi C; Papanikolaou N; Charlton M
    Med Phys; 2011 Mar; 38(3):1141-9. PubMed ID: 21520826
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the contribution of capture gamma rays, x-ray leakage, and scatter to the photon dose at the maze door for a high energy medical electron accelerator using a Monte Carlo particle transport code.
    McGinley PH; Dhaba'an AH; Reft CS
    Med Phys; 2000 Jan; 27(1):225-30. PubMed ID: 10659761
    [TBL] [Abstract][Full Text] [Related]  

  • 8. On the production of neutrons in laminated barriers for 10 MV medical accelerator rooms.
    Facure A; da Silva AX; da Rosa LA; Cardoso SC; Rezende GF
    Med Phys; 2008 Jul; 35(7):3285-92. PubMed ID: 18697553
    [TBL] [Abstract][Full Text] [Related]  

  • 9. New empirical formula for neutron dose level at the maze entrance of 15 MV medical accelerator facilities.
    Kim HS; Jang KW; Park YH; Kwon JW; Choi HS; Lee JK; Kim JK
    Med Phys; 2009 May; 36(5):1512-20. PubMed ID: 19544767
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dose rates and energy spectra in the maze of a linear accelerator treatment room.
    Morgan S; Morgan HM; Lillicrap SC
    Br J Radiol; 1995 Nov; 68(815):1237-41. PubMed ID: 8542232
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Neutron dose calculation at the maze entrance of medical linear accelerator rooms.
    Falcão RC; Facure A; Silva AX
    Radiat Prot Dosimetry; 2007; 123(3):283-7. PubMed ID: 17005540
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Photon doses at the entrance of 60Co and low-energy medical accelerator rooms under unusual irradiation conditions.
    Facure A; Cardoso SC; da Rosa LA; da Silva AX
    Radiat Prot Dosimetry; 2010 Mar; 138(3):251-6. PubMed ID: 19965909
    [TBL] [Abstract][Full Text] [Related]  

  • 13. On the tenth value distance of the photon field along the maze of high-energy linear accelerator vaults.
    Han Z; Chin LM
    J Appl Clin Med Phys; 2018 Mar; 19(2):311-316. PubMed ID: 29374424
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of a paraffin screen on the neutron dose at the maze door of a 15 MV linear accelerator.
    Krmar M; Nikolić D; Kuzmanović A; Kuzmanović Z; Ganezer K
    Med Phys; 2013 Aug; 40(8):083902. PubMed ID: 23927362
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of the photoneutron field produced in a medical linear accelerator.
    Kim HS; Park YH; Koo BC; Kwon JW; Lee JS; Choi HS
    Radiat Prot Dosimetry; 2007; 123(3):323-8. PubMed ID: 17077093
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monte Carlo simulation of scattered and thermal photoneutron fluences inside a radiotherapy room.
    Facure A; Da Silva AX; Falcão RC
    Radiat Prot Dosimetry; 2007; 123(1):56-61. PubMed ID: 16815885
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effectiveness of customised neutron shielding in the maze of radiotherapy accelerators.
    Waller EJ; Jamieson TJ; Cole D; Cousins T; Jammal RB
    Radiat Prot Dosimetry; 2003; 107(4):233-8. PubMed ID: 14756179
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Monte Carlo simulations of ceiling scatter in nuclear medicine:
    Schnerr RS; de Jong AN; Landry G; Jeukens CR; Wierts R
    Med Phys; 2017 Mar; 44(3):1113-1119. PubMed ID: 28097674
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Room scattered neutrons.
    McCall RC; McGinley PH; Huffman KE
    Med Phys; 1999 Feb; 26(2):206-7. PubMed ID: 10076975
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Air kerma transmission factors of Scattered X-rays in the maze of a Linac room for lead shield].
    Kato H
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2005 Jan; 61(1):96-103. PubMed ID: 15682037
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.