These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

248 related articles for article (PubMed ID: 28981424)

  • 1. Continuous Separation of White Blood Cells From Whole Blood Using Viscoelastic Effects.
    Tan JKS; Park SY; Leo HL; Kim S
    IEEE Trans Biomed Circuits Syst; 2017 Dec; 11(6):1431-1437. PubMed ID: 28981424
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-Throughput Separation of White Blood Cells From Whole Blood Using Inertial Microfluidics.
    Zhang J; Yuan D; Sluyter R; Yan S; Zhao Q; Xia H; Tan SH; Nguyen NT; Li W
    IEEE Trans Biomed Circuits Syst; 2017 Dec; 11(6):1422-1430. PubMed ID: 28866599
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A microfluidic device for continuous white blood cell separation and lysis from whole blood.
    Kim M; Mo Jung S; Lee KH; Jun Kang Y; Yang S
    Artif Organs; 2010 Nov; 34(11):996-1002. PubMed ID: 21092042
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Micropump integrated white blood cell separation platform for detection of chronic granulomatous disease.
    Mane S; Behera A; Hemadri V; Bhand S; Tripathi S
    Mikrochim Acta; 2024 May; 191(5):295. PubMed ID: 38700804
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Non-electrical powered continuous cell concentration for enumeration of residual white blood cells in WBC-depleted blood using a viscoelastic fluid.
    Nam J; Jang WS; Lim CS
    Talanta; 2019 May; 197():12-19. PubMed ID: 30771912
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Continuous-flow microfluidic blood cell sorting for unprocessed whole blood using surface-micromachined microfiltration membranes.
    Li X; Chen W; Liu G; Lu W; Fu J
    Lab Chip; 2014 Jul; 14(14):2565-75. PubMed ID: 24895109
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Perfusion in microfluidic cross-flow: separation of white blood cells from whole blood and exchange of medium in a continuous flow.
    VanDelinder V; Groisman A
    Anal Chem; 2007 Mar; 79(5):2023-30. PubMed ID: 17249639
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous erythrocyte removal and leukocyte separation from whole blood based on viscoelastic cell focusing and the margination phenomenon.
    Nam J; Yoon J; Kim J; Jang WS; Lim CS
    J Chromatogr A; 2019 Jun; 1595():230-239. PubMed ID: 30772054
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Microfluidic co-flow of Newtonian and viscoelastic fluids for high-resolution separation of microparticles.
    Tian F; Zhang W; Cai L; Li S; Hu G; Cong Y; Liu C; Li T; Sun J
    Lab Chip; 2017 Sep; 17(18):3078-3085. PubMed ID: 28805872
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A flyover style microfluidic chip for highly purified magnetic cell separation.
    Lin S; Zhi X; Chen D; Xia F; Shen Y; Niu J; Huang S; Song J; Miao J; Cui D; Ding X
    Biosens Bioelectron; 2019 Mar; 129():175-181. PubMed ID: 30710755
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Microfluidic device for sheathless particle focusing and separation using a viscoelastic fluid.
    Nam J; Namgung B; Lim CT; Bae JE; Leo HL; Cho KS; Kim S
    J Chromatogr A; 2015 Aug; 1406():244-50. PubMed ID: 26122857
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Portable platform for leukocyte extraction from blood using sheath-free microfluidic DLD.
    Chavez-Pineda OG; Rodriguez-Moncayo R; Gonzalez-Suarez AM; Guevara-Pantoja PE; Maravillas-Montero JL; Garcia-Cordero JL
    Lab Chip; 2024 Apr; 24(9):2575-2589. PubMed ID: 38646820
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Microfluidic immunomagnetic cell separation from whole blood.
    Bhuvanendran Nair Gourikutty S; Chang CP; Puiu PD
    J Chromatogr B Analyt Technol Biomed Life Sci; 2016 Feb; 1011():77-88. PubMed ID: 26773879
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A simple microfluidic device for the deformability assessment of blood cells in a continuous flow.
    Rodrigues RO; Pinho D; Faustino V; Lima R
    Biomed Microdevices; 2015 Dec; 17(6):108. PubMed ID: 26482154
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Viscoelastic Separation and Concentration of Fungi from Blood for Highly Sensitive Molecular Diagnostics.
    Nam J; Jang WS; Hong DH; Lim CS
    Sci Rep; 2019 Feb; 9(1):3067. PubMed ID: 30816161
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Lab-on-a-chip device for continuous particle and cell separation based on electrical properties via alternating current dielectrophoresis.
    Cetin B; Li D
    Electrophoresis; 2010 Sep; 31(18):3035-43. PubMed ID: 20872609
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Continuous separation of fungal spores in a microfluidic flow focusing device.
    Park BS; Kye HG; Kim TH; Lee JM; Ahrberg CD; Cho EM; Yang SI; Chung BG
    Analyst; 2019 Aug; 144(16):4962-4971. PubMed ID: 31322144
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High-throughput malaria parasite separation using a viscoelastic fluid for ultrasensitive PCR detection.
    Nam J; Shin Y; Tan JK; Lim YB; Lim CT; Kim S
    Lab Chip; 2016 May; 16(11):2086-92. PubMed ID: 27160315
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Micropillar array chip for integrated white blood cell isolation and PCR.
    Panaro NJ; Lou XJ; Fortina P; Kricka LJ; Wilding P
    Biomol Eng; 2005 Feb; 21(6):157-62. PubMed ID: 15748689
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An integrated on-chip platform for negative enrichment of tumour cells.
    Bhuvanendran Nair Gourikutty S; Chang CP; Poenar DP
    J Chromatogr B Analyt Technol Biomed Life Sci; 2016 Aug; 1028():153-164. PubMed ID: 27344255
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.