These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 28982150)

  • 1. Ocular biometric measurements in cataract surgery candidates in Portugal.
    Ferreira TB; Hoffer KJ; Ribeiro F; Ribeiro P; O'Neill JG
    PLoS One; 2017; 12(10):e0184837. PubMed ID: 28982150
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biometry data and prevalence of corneal astigmatism in caucasian spanish candidates for cataract surgery.
    Arriola-Villalobos P; Burgos-Blasco B; Fernández-Vigo JI; Ariño-Gutiérrez M; Burgos-Blasco P; Carmona-González D; Fernández-Pérez C
    J Fr Ophtalmol; 2021 Jan; 44(1):76-83. PubMed ID: 33162179
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Distribution of ocular biometric parameters and optimal model of anterior chamber depth regression in 28,709 adult cataract patients in China using swept-source optical biometry.
    Lei Q; Tu H; Feng X; Ortega-Usobiaga J; Cao D; Wang Y
    BMC Ophthalmol; 2021 Apr; 21(1):178. PubMed ID: 33849464
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ocular Biometric Characteristics Measured by Swept-Source Optical Coherence Tomography in Individuals Undergoing Cataract Surgery.
    Wasser LM; Tsessler M; Weill Y; Zadok D; Abulafia A
    Am J Ophthalmol; 2022 Jan; 233():38-47. PubMed ID: 34314687
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Changes in ocular biometric parameters after renal transplantation.
    Aksoy M; Asena L; Gungor SG; Soy EHA; Akman A; Haberal M
    Int Ophthalmol; 2020 Sep; 40(9):2283-2289. PubMed ID: 32415655
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of two optical biometers in intraocular lens power calculation.
    Hui S; Yi L
    Indian J Ophthalmol; 2014 Sep; 62(9):931-4. PubMed ID: 25370395
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ocular Biometric Values and Prevalence of Corneal Astigmatism in Patients Candidate for Cataract Surgery.
    Hashemian SJ; Hashemian SM; Karimian F; Hadavandkhani A; Jafari ME; Hashemian MS; Hadi Y; Semnani FN
    J Curr Ophthalmol; 2022; 34(1):56-59. PubMed ID: 35620375
    [TBL] [Abstract][Full Text] [Related]  

  • 8. SS-OCT-based ocular biometry in an adult Korean population with cataract.
    Kim S; Oh R; Kim MK; Yoon CH
    J Cataract Refract Surg; 2023 May; 49(5):453-459. PubMed ID: 36700930
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Influence of measurement differences of anterior chamber depth and axial length on lens thickness evaluation in cataract patients: a comparison of two tests.
    Xu J; Li C; Wang L; Li C; Li X; Lu P
    BMC Ophthalmol; 2020 Dec; 20(1):481. PubMed ID: 33287752
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ocular biometric changes with different accommodative stimuli using swept-source optical coherence tomography.
    Ferrer-Blasco T; Esteve-Taboada JJ; Monsálvez-Romín D; Aloy MA; Adsuara JE; Cerdá-Durán P; Montés-Micó R
    Int Ophthalmol; 2019 Feb; 39(2):303-310. PubMed ID: 29260498
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of biometry and corneal astigmatism in cataract surgery patients in Northern United Arab Emirates.
    Han ES; Kim M
    Int Ophthalmol; 2019 Dec; 39(12):2807-2813. PubMed ID: 31134425
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Refractive error, ocular biometry, and lens opalescence in an adult population: the Los Angeles Latino Eye Study.
    Shufelt C; Fraser-Bell S; Ying-Lai M; Torres M; Varma R;
    Invest Ophthalmol Vis Sci; 2005 Dec; 46(12):4450-60. PubMed ID: 16303933
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biometry and corneal astigmatism in cataract surgery candidates from Southern China.
    Cui Y; Meng Q; Guo H; Zeng J; Zhang H; Zhang G; Huang Y; Lan J
    J Cataract Refract Surg; 2014 Oct; 40(10):1661-9. PubMed ID: 25149557
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analysis of biometric parameters of 2340 eyes measured with optical biometer Lenstar LS900 in a Caucasian population.
    Popov I; Waczulikova I; Stefanickova J; Valaskova J; Tomcikova D; Shiwani HA; Delev D; Rodrigo L; Saxena S; Kruzliak P; Krasnik V
    Eur J Ophthalmol; 2022 Jan; 32(1):213-220. PubMed ID: 33653160
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Relationship between Crystalline Lens Thickness and Shape and the Identification of Anterior Ocular Segment Parameters for Predicting the Intraocular Lens Position after Cataract Surgery.
    Satou T; Shimizu K; Tsunehiro S; Igarashi A; Kato S; Koshimizu M; Niida T
    Biomed Res Int; 2019; 2019():3458548. PubMed ID: 31360711
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Relationship between age, corneal astigmatism, and ocular dimensions with reference to astigmatism in eyes undergoing routine cataract surgery.
    Collier Wakefield O; Annoh R; Nanavaty MA
    Eye (Lond); 2016 Apr; 30(4):562-9. PubMed ID: 26795412
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of biometry and corneal astigmatism in cataract surgery patients from Central China.
    Yu JG; Zhong J; Mei ZM; Zhao F; Tao N; Xiang Y
    BMC Ophthalmol; 2017 Apr; 17(1):56. PubMed ID: 28446167
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ocular biometric characteristics of cataract patients in western China.
    Huang Q; Huang Y; Luo Q; Fan W
    BMC Ophthalmol; 2018 Apr; 18(1):99. PubMed ID: 29665792
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Astigmatism prevalence and biometric analysis in normal population.
    Nemeth G; Szalai E; Berta A; Modis L
    Eur J Ophthalmol; 2013; 23(6):779-83. PubMed ID: 23640506
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prevalence of corneal astigmatism before cataract surgery.
    Mohammadi M; Naderan M; Pahlevani R; Jahanrad A
    Int Ophthalmol; 2016 Dec; 36(6):807-817. PubMed ID: 26909501
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.