These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 28983885)

  • 21. A Monte Carlo model for retrospective analysis of shield design in a diagnostic x-ray room.
    Metzger R; Richardson R; Van Riper KA
    Health Phys; 1993 Aug; 65(2):164-71. PubMed ID: 8330963
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Shielding Design for Adjacent, Underground Buildings of a Megavoltage Radiotherapy Facility.
    Sanz DE
    Health Phys; 2016 Jul; 111(1):1-10. PubMed ID: 27218288
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Medical radiography at sea.
    Wright A
    Health Phys; 2005 May; 88(5 Suppl):S79-83. PubMed ID: 15824587
    [TBL] [Abstract][Full Text] [Related]  

  • 24. X-ray spectroscopy applied to radiation shielding calculation in mammography.
    Künzel R; Levenhagen RS; Herdade SB; Terini RA; Costa PR
    Med Phys; 2008 Aug; 35(8):3539-45. PubMed ID: 18777914
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Maximum dose angle for oblique incidence on primary beam protective barriers in the design of medical radiation therapy facilities.
    Fondevila D; Arbiser S; Sansogne R; Brunetto M; Dosoretz B
    Med Phys; 2008 May; 35(5):1816-9. PubMed ID: 18561656
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Radiation Oncology-External-Beam Radiation Therapy.
    Martin MC
    Health Phys; 2019 Feb; 116(2):184-188. PubMed ID: 30585962
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Scatter radiation intensities around a clinical digital breast tomosynthesis unit and the impact on radiation shielding considerations.
    Yang K; Li X; Liu B
    Med Phys; 2016 Mar; 43(3):1096-110. PubMed ID: 26936697
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effective dose as a limiting quantity for the evaluation of primary barriers for diagnostic x-ray facilities.
    Okunade AA
    Health Phys; 2005 Nov; 89(5 Suppl):S100-16. PubMed ID: 16224257
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Radiation dose reduction to the breast in thoracic CT: comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current.
    Wang J; Duan X; Christner JA; Leng S; Yu L; McCollough CH
    Med Phys; 2011 Nov; 38(11):6084-92. PubMed ID: 22047373
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Evaluation of the shielding in a treatment room with an electronic brachytherapy unit.
    Ibanez-Rosello B; Bautista-Ballesteros JA; Candela-Juan C; Villaescusa JI; Ballester F; Vijande J; Perez-Calatayud J
    J Radiol Prot; 2017 Jun; 37(2):N5-N12. PubMed ID: 28253202
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Radiation shielding of multiple x-ray sources in diagnostic radiology.
    Simpkin DJ
    Health Phys; 1986 Jan; 50(1):117-22. PubMed ID: 3943961
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Primary shielding barriers for diagnostic x-ray facilities: a new model.
    Dixon RL; Simpkin DJ
    Health Phys; 1998 Feb; 74(2):181-9. PubMed ID: 9450588
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Comparison of shielding calculations for diagnostic X-ray equipment].
    Noto K; Sota T; Koshida K; Suzuki S
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2003 Aug; 59(8):976-83. PubMed ID: 12960951
    [TBL] [Abstract][Full Text] [Related]  

  • 34. On the primary barrier in diagnostic x-ray shielding.
    Dixon RL
    Med Phys; 1994 Nov; 21(11):1785-93. PubMed ID: 7891641
    [TBL] [Abstract][Full Text] [Related]  

  • 35. PShield: an exact three-dimensional numerical solution for determining optimal shielding designs for PET/CT facilities.
    Pasciak AS; Jones AK
    Med Phys; 2012 Jun; 39(6):3060-9. PubMed ID: 22755691
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The diagnostic X-ray protection characteristics of Ytong, an aerated concrete based building material.
    Tsalafoutas IA; Yakoumakis E; Manetou A; Flioni-Vyza A
    Br J Radiol; 1998 Sep; 71(849):944-9. PubMed ID: 10195009
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Shielding considerations for tomotherapy.
    Robinson D; Scrimger JW; Field GC; Fallone BG
    Med Phys; 2000 Oct; 27(10):2380-4. PubMed ID: 11099208
    [TBL] [Abstract][Full Text] [Related]  

  • 38. AAPM Task Group 108: PET and PET/CT shielding requirements.
    Madsen MT; Anderson JA; Halama JR; Kleck J; Simpkin DJ; Votaw JR; Wendt RE; Williams LE; Yester MV
    Med Phys; 2006 Jan; 33(1):4-15. PubMed ID: 16485403
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Radiographic workload and use factors for orthopedic facilities.
    Bushong SC; Glaze SA
    Health Phys; 1983 Jan; 44(1):53-9. PubMed ID: 6826366
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A conversion method of air kerma from the primary, scatter, and leakage radiations to effective dose for calculating x-ray shielding barriers in mammography.
    Kharrati H
    Med Phys; 2005 May; 32(5):1367-74. PubMed ID: 15984688
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.