These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

134 related articles for article (PubMed ID: 28992697)

  • 1. An Accurate Model for the Ion Current-Distance Behavior in Scanning Ion Conductance Microscopy Allows for Calibration of Pipet Tip Geometry and Tip-Sample Distance.
    Rheinlaender J; Schäffer TE
    Anal Chem; 2017 Nov; 89(21):11875-11880. PubMed ID: 28992697
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Lateral Resolution and Image Formation in Scanning Ion Conductance Microscopy.
    Rheinlaender J; Schäffer TE
    Anal Chem; 2015 Jul; 87(14):7117-24. PubMed ID: 26098306
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Method for estimating the tip geometry of scanning ion conductance microscope pipets.
    Caldwell M; Del Linz SJ; Smart TG; Moss GW
    Anal Chem; 2012 Nov; 84(21):8980-4. PubMed ID: 23082744
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of sample slope on image formation in scanning ion conductance microscopy.
    Thatenhorst D; Rheinlaender J; Schäffer TE; Dietzel ID; Happel P
    Anal Chem; 2014 Oct; 86(19):9838-45. PubMed ID: 25220029
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A High Accuracy Ion Conductance Imaging Method Based on the Approach Curve Spectrum.
    Jiao Y; Zhuang J; Zheng Q; Liao X
    Ultramicroscopy; 2020 Aug; 215():113025. PubMed ID: 32485394
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hierarchical spiral-scan trajectory for efficient scanning ion conductance microscopy.
    Zhuang J; Wang Z; Liao X; Gao B; Cheng L
    Micron; 2019 Aug; 123():102683. PubMed ID: 31129536
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new scanning mode to improve scanning ion conductance microscopy imaging rate with pipette predicted movement.
    Zhuang J; Jiao Y; Mugabo V
    Micron; 2017 Oct; 101():177-185. PubMed ID: 28763735
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Scanning ion conductance microscopy for visualizing the three-dimensional surface topography of cells and tissues.
    Nakajima M; Mizutani Y; Iwata F; Ushiki T
    Semin Cell Dev Biol; 2018 Jan; 73():125-131. PubMed ID: 28939037
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analysis and improvement of positioning reliability and accuracy of theta pipette configuration for scanning ion conductance microscopy.
    Jiao Y; Zhuang J; Li F; Zheng Q; Gao Z
    Ultramicroscopy; 2021 May; 224():113240. PubMed ID: 33689886
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Integrated ultramicroelectrode-nanopipet probe for concurrent scanning electrochemical microscopy and scanning ion conductance microscopy.
    Comstock DJ; Elam JW; Pellin MJ; Hersam MC
    Anal Chem; 2010 Feb; 82(4):1270-6. PubMed ID: 20073475
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Polished nanopipets: new probes for high-resolution scanning electrochemical microscopy.
    Elsamadisi P; Wang Y; Velmurugan J; Mirkin MV
    Anal Chem; 2011 Feb; 83(3):671-3. PubMed ID: 21162580
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Multifunctional scanning ion conductance microscopy.
    Page A; Perry D; Unwin PR
    Proc Math Phys Eng Sci; 2017 Apr; 473(2200):20160889. PubMed ID: 28484332
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Scanning ion conductance microscopy of isolated metaphase chromosomes in a liquid environment.
    Ushiki T; Ishizaki K; Mizutani Y; Nakajima M; Iwata F
    Chromosome Res; 2021 Mar; 29(1):95-106. PubMed ID: 33694044
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Characterization of tip size and geometry of the pipettes used in scanning ion conductance microscopy.
    Tognoni E; Baschieri P; Ascoli C; Pellegrini M; Pellegrino M
    Micron; 2016 Apr; 83():11-8. PubMed ID: 26826619
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A continuous control mode with improved imaging rate for scanning ion conductance microscope (SICM).
    Zhuang J; Jiao Y; Li Z; Lang J; Li F
    Ultramicroscopy; 2018 Jul; 190():66-76. PubMed ID: 29689446
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simultaneous Interfacial Reactivity and Topography Mapping with Scanning Ion Conductance Microscopy.
    Momotenko D; McKelvey K; Kang M; Meloni GN; Unwin PR
    Anal Chem; 2016 Mar; 88(5):2838-46. PubMed ID: 26798938
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of pipette modulation and imaging distances on ion currents measured with scanning ion conductance microscopy (SICM).
    Chen CC; Baker LA
    Analyst; 2011 Jan; 136(1):90-7. PubMed ID: 21103593
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Scanning ion conductance microscopy: a model for experimentally realistic conditions and image interpretation.
    Edwards MA; Williams CG; Whitworth AL; Unwin PR
    Anal Chem; 2009 Jun; 81(11):4482-92. PubMed ID: 19405486
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Potentiometric-scanning ion conductance microscopy.
    Zhou Y; Chen CC; Weber AE; Zhou L; Baker LA
    Langmuir; 2014 May; 30(19):5669-75. PubMed ID: 24773406
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simulating imaging with the scanning ion-conductance microscope.
    Adenle O; Fitzgerald W
    Conf Proc IEEE Eng Med Biol Soc; 2005; 2005():3410-3. PubMed ID: 17280955
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.