145 related articles for article (PubMed ID: 28993019)
1. A modified formula for dose calculations of stereotactic ablative body radiotherapy for non-small cell lung cancer.
Cao Y; Zhu X; Zhang Y; Yu C; Liu Y; Sun Y; Dai Z; Guo X; Ju X; Zhang H
Med Dosim; 2018 Autumn; 43(3):207-213. PubMed ID: 28993019
[TBL] [Abstract][Full Text] [Related]
2. Assessment of Monte Carlo algorithm for compliance with RTOG 0915 dosimetric criteria in peripheral lung cancer patients treated with stereotactic body radiotherapy.
Pokhrel D; Sood S; Badkul R; Jiang H; McClinton C; Lominska C; Kumar P; Wang F
J Appl Clin Med Phys; 2016 May; 17(3):277-293. PubMed ID: 27167284
[TBL] [Abstract][Full Text] [Related]
3. Technical Note: Dosimetric evaluation of Monte Carlo algorithm in iPlan for stereotactic ablative body radiotherapy (SABR) for lung cancer patients using RTOG 0813 parameters.
Pokhrel D; Badkul R; Jiang H; Kumar P; Wang F
J Appl Clin Med Phys; 2015 Jan; 16(1):5058. PubMed ID: 25679161
[TBL] [Abstract][Full Text] [Related]
4. Dosimetric differences between local failure and local controlled non-small cell lung cancer patients treated with stereotactic body radiotherapy: A matched-pair study.
Zhuang T; Woody NM; Liu H; Cherian S; Reddy CA; Qi P; Magnelli A; Djemil T; Stephans KL; Xia P; Videtic GM
J Med Imaging Radiat Oncol; 2018 Jun; 62(3):420-424. PubMed ID: 29399972
[TBL] [Abstract][Full Text] [Related]
5. Radiobiological impact of dose calculation algorithms on biologically optimized IMRT lung stereotactic body radiation therapy plans.
Liang X; Penagaricano J; Zheng D; Morrill S; Zhang X; Corry P; Griffin RJ; Han EY; Hardee M; Ratanatharathom V
Radiat Oncol; 2016 Jan; 11():10. PubMed ID: 26800883
[TBL] [Abstract][Full Text] [Related]
6. Comparison of Ray Tracing and Monte Carlo Calculation Algorithms for Thoracic Spine Lesions Treated With CyberKnife-Based Stereotactic Body Radiation Therapy.
Okoye CC; Patel RB; Hasan S; Podder T; Khouri A; Fabien J; Zhang Y; Dobbins D; Sohn JW; Yuan J; Yao M; Machtay M; Sloan AE; Miller J; Lo SS
Technol Cancer Res Treat; 2016 Feb; 15(1):196-202. PubMed ID: 25633137
[TBL] [Abstract][Full Text] [Related]
7. Influence of CyberKnife Prescription Isodose Line on the Discrepancy of Dose Results Calculated by the Ray Tracing and Monte Carlo Algorithms for Head and Lung Plans: A Phantom Study.
Yang J; Liu G; Liu HY; Nie X; Yang ZY; Han J; Zhang S; Liang ZW
Curr Med Sci; 2020 Apr; 40(2):301-306. PubMed ID: 32337689
[TBL] [Abstract][Full Text] [Related]
8. Correlation of dose computed using different algorithms with local control following stereotactic ablative radiotherapy (SABR)-based treatment of non-small-cell lung cancer.
Chetty IJ; Devpura S; Liu D; Chen D; Li H; Wen NW; Kumar S; Fraser C; Siddiqui MS; Ajlouni M; Movsas B
Radiother Oncol; 2013 Dec; 109(3):498-504. PubMed ID: 24231237
[TBL] [Abstract][Full Text] [Related]
9. Dose calculation differences between Monte Carlo and pencil beam depend on the tumor locations and volumes for lung stereotactic body radiation therapy.
Zhuang T; Djemil T; Qi P; Magnelli A; Stephans K; Videtic G; Xia P
J Appl Clin Med Phys; 2013 Mar; 14(2):4011. PubMed ID: 23470930
[TBL] [Abstract][Full Text] [Related]
10. On the use of a convolution-superposition algorithm for plan checking in lung stereotactic body radiation therapy.
Hardcastle N; Oborn BM; Haworth A
J Appl Clin Med Phys; 2016 Sep; 17(5):99-110. PubMed ID: 27685114
[TBL] [Abstract][Full Text] [Related]
11. Dosimetric verification using monte carlo calculations for tissue heterogeneity-corrected conformal treatment plans following RTOG 0813 dosimetric criteria for lung cancer stereotactic body radiotherapy.
Li J; Galvin J; Harrison A; Timmerman R; Yu Y; Xiao Y
Int J Radiat Oncol Biol Phys; 2012 Oct; 84(2):508-13. PubMed ID: 22365630
[TBL] [Abstract][Full Text] [Related]
12. Dosimetric comparison of lung stereotactic body radiotherapy treatment plans using averaged computed tomography and end-exhalation computed tomography images: Evaluation of the effect of different dose-calculation algorithms and prescription methods.
Mitsuyoshi T; Nakamura M; Matsuo Y; Ueki N; Nakamura A; Iizuka Y; Mampuya WA; Mizowaki T; Hiraoka M
Med Dosim; 2016 Winter; 41(4):305-309. PubMed ID: 27623737
[TBL] [Abstract][Full Text] [Related]
13. Effect of the normalized prescription isodose line on the magnitude of Monte Carlo vs. pencil beam target dose differences for lung stereotactic body radiotherapy.
Zheng D; Zhang Q; Liang X; Zhu X; Verma V; Wang S; Zhou S
J Appl Clin Med Phys; 2016 Jul; 17(4):48-58. PubMed ID: 27455476
[TBL] [Abstract][Full Text] [Related]
14. Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT.
Liu H; Zhuang T; Stephans K; Videtic G; Raithel S; Djemil T; Xia P
J Appl Clin Med Phys; 2015 Nov; 16(6):91–99. PubMed ID: 26699560
[TBL] [Abstract][Full Text] [Related]
15. A phase I/II study on stereotactic body radiotherapy with real-time tumor tracking using CyberKnife based on the Monte Carlo algorithm for lung tumors.
Iwata H; Ishikura S; Murai T; Iwabuchi M; Inoue M; Tatewaki K; Ohta S; Yokota N; Shibamoto Y
Int J Clin Oncol; 2017 Aug; 22(4):706-714. PubMed ID: 28429140
[TBL] [Abstract][Full Text] [Related]
16. Comparison of pencil beam-based homogeneous vs inhomogeneous target dose planning for stereotactic body radiotherapy of peripheral lung tumors through Monte Carlo-based recalculation.
Ohtakara K; Hoshi H
Med Dosim; 2015; 40(3):248-55. PubMed ID: 25776903
[TBL] [Abstract][Full Text] [Related]
17. Optimization of leaf margins for lung stereotactic body radiotherapy using a flattening filter-free beam.
Wakai N; Sumida I; Otani Y; Suzuki O; Seo Y; Isohashi F; Yoshioka Y; Hasegawa M; Ogawa K
Med Phys; 2015 May; 42(5):2125-31. PubMed ID: 25979007
[TBL] [Abstract][Full Text] [Related]
18. Clinical introduction of Monte Carlo treatment planning for lung stereotactic body radiotherapy.
Miura H; Masai N; Oh RJ; Shiomi H; Yamada K; Sasaki J; Inoue T
J Appl Clin Med Phys; 2014 Jan; 15(1):4202. PubMed ID: 24423832
[TBL] [Abstract][Full Text] [Related]
19. Adapted Prescription Dose for Monte Carlo Algorithm in Lung SBRT: Clinical Outcome on 205 Patients.
Bibault JE; Mirabel X; Lacornerie T; Tresch E; Reynaert N; Lartigau E
PLoS One; 2015; 10(7):e0133617. PubMed ID: 26207808
[TBL] [Abstract][Full Text] [Related]
20. Clinical introduction of Monte Carlo treatment planning: a different prescription dose for non-small cell lung cancer according to tumor location and size.
van der Voort van Zyp NC; Hoogeman MS; van de Water S; Levendag PC; van der Holt B; Heijmen BJ; Nuyttens JJ
Radiother Oncol; 2010 Jul; 96(1):55-60. PubMed ID: 20430461
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]