These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
115 related articles for article (PubMed ID: 29017735)
1. Re: re: Heat generation and drill wear during dental implant site preparation: systematic review. Möhlhenrich SC; Modabber A; Steiner T; Mitchell DA; Hölzle F Br J Oral Maxillofac Surg; 2017 Nov; 55(9):985-986. PubMed ID: 29017735 [No Abstract] [Full Text] [Related]
2. Re: Heat generation and drill wear during dental implant site preparation. Koopaie M; Kolahdouz S Br J Oral Maxillofac Surg; 2017 Nov; 55(9):985. PubMed ID: 29017733 [No Abstract] [Full Text] [Related]
3. Improved Dental Implant Drill Durability and Performance Using Heat and Wear Resistant Protective Coatings. Er N; Alkan A; Ilday S; Bengu E J Oral Implantol; 2018 Jun; 44(3):168-175. PubMed ID: 29498904 [TBL] [Abstract][Full Text] [Related]
4. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability. Ercoli C; Funkenbusch PD; Lee HJ; Moss ME; Graser GN Int J Oral Maxillofac Implants; 2004; 19(3):335-49. PubMed ID: 15214217 [TBL] [Abstract][Full Text] [Related]
5. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites. Brisman DL Int J Oral Maxillofac Implants; 1996; 11(1):35-7. PubMed ID: 8820120 [TBL] [Abstract][Full Text] [Related]
6. Influence of the drill material and method of cooling on the development of intrabony temperature during preparation of the site of an implant. Harder S; Egert C; Wenz HJ; Jochens A; Kern M Br J Oral Maxillofac Surg; 2013 Jan; 51(1):74-8. PubMed ID: 22417718 [TBL] [Abstract][Full Text] [Related]
7. [Heat distribution within the bone tissue by rotary cutting instrument for IMZ implant. Heat analysis by a real-time thermography]. Watanabe F; Tawada Y; Komatsu S; Hata Y Nihon Hotetsu Shika Gakkai Zasshi; 1990 Feb; 34(1):18-24. PubMed ID: 2134919 [TBL] [Abstract][Full Text] [Related]
8. An investigation on heat transfer to the implant-bone interface due to abutment preparation with high-speed cutting instruments. Gross M; Laufer BZ; Ormianar Z Int J Oral Maxillofac Implants; 1995; 10(2):207-12. PubMed ID: 7744440 [TBL] [Abstract][Full Text] [Related]
9. Effect of surgical drill guide on heat generated from implant drilling. Misir AF; Sumer M; Yenisey M; Ergioglu E J Oral Maxillofac Surg; 2009 Dec; 67(12):2663-8. PubMed ID: 19925988 [TBL] [Abstract][Full Text] [Related]
10. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part I: Relationship between drill speed and heat production. Iyer S; Weiss C; Mehta A Int J Prosthodont; 1997; 10(5):411-4. PubMed ID: 9495159 [TBL] [Abstract][Full Text] [Related]
11. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: Relationship between drill speed and healing. Iyer S; Weiss C; Mehta A Int J Prosthodont; 1997; 10(6):536-40. PubMed ID: 9495174 [TBL] [Abstract][Full Text] [Related]
12. Thermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: twisted stainless steel and ceramic drills. Oliveira N; Alaejos-Algarra F; Mareque-Bueno J; Ferrés-Padró E; Hernández-Alfaro F Clin Oral Implants Res; 2012 Aug; 23(8):963-9. PubMed ID: 21806686 [TBL] [Abstract][Full Text] [Related]
13. Effect of irrigation and stainless steel drills on dental implant bed heat generation. Bullon B; Bueno EF; Herrero M; Fernandez-Palacin A; Rios JV; Bullon P; Gil FJ J Mater Sci Mater Med; 2015 Feb; 26(2):75. PubMed ID: 25631272 [TBL] [Abstract][Full Text] [Related]
14. Heat generation and drill wear during dental implant site preparation: systematic review. Möhlhenrich SC; Modabber A; Steiner T; Mitchell DA; Hölzle F Br J Oral Maxillofac Surg; 2015 Oct; 53(8):679-89. PubMed ID: 26051868 [TBL] [Abstract][Full Text] [Related]
15. Clinical Influence of Micromorphological Structure of Dental Implant Bone Drills. Marenzi G; Sammartino JC; Quaremba G; Graziano V; El Hassanin A; Qorri ME; Sammartino G; Iorio-Siciliano V Biomed Res Int; 2018; 2018():8143962. PubMed ID: 29984249 [TBL] [Abstract][Full Text] [Related]
16. Effects of Different Implant Osteotomy Preparation Sizes on Implant Stability and Bone Response in the Minipig Mandible. Eom TG; Kim HW; Jeon GR; Yun MJ; Huh JB; Jeong CM Int J Oral Maxillofac Implants; 2016; 31(5):997-1006. PubMed ID: 27632253 [TBL] [Abstract][Full Text] [Related]
17. Heat generated during seating of dental implant fixtures. Flanagan D J Oral Implantol; 2014 Apr; 40(2):174-81. PubMed ID: 24400840 [TBL] [Abstract][Full Text] [Related]
18. The Evaluation of the Heat Generated by the Implant Osteotomy Preparation Using a Modified Method of the Measuring Temperature. Yamaba T; Suganami T; Ikebe K; Sogo M; Maeda Y; Wada M Int J Oral Maxillofac Implants; 2015; 30(4):820-6. PubMed ID: 26252034 [TBL] [Abstract][Full Text] [Related]
19. Infrared thermographic evaluation of temperature modifications induced during implant site preparation with cylindrical versus conical drills. Scarano A; Piattelli A; Assenza B; Carinci F; Di Donato L; Romani GL; Merla A Clin Implant Dent Relat Res; 2011 Dec; 13(4):319-23. PubMed ID: 19681941 [TBL] [Abstract][Full Text] [Related]
20. Effect of implant drill characteristics on heat generation in osteotomy sites: a pilot study. Oh HJ; Wikesjö UM; Kang HS; Ku Y; Eom TG; Koo KT Clin Oral Implants Res; 2011 Jul; 22(7):722-726. PubMed ID: 21143537 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]