These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 29021879)

  • 1. A Comparison of Plain Radiography with Computer Tomography in Determining Coronal and Sagittal Alignments following Total Knee Arthroplasty.
    Solayar GN; Chinappa J; Harris IA; Chen DB; Macdessi SJ
    Malays Orthop J; 2017 Jul; 11(2):45-52. PubMed ID: 29021879
    [No Abstract]   [Full Text] [Related]  

  • 2. Comparison of CT and EOS in assessing coronal lower limb alignment when planning total knee arthroplasty.
    Corbett J; Tai J; Salmon L; Roe J
    Knee; 2023 Jun; 42():400-408. PubMed ID: 37182443
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment.
    Moon YW; Ha CW; Do KH; Kim CY; Han JH; Na SE; Lee CH; Kim JG; Park YS
    Comput Aided Surg; 2012; 17(2):86-95. PubMed ID: 22348661
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Arithmetic hip knee angle measurement on long leg radiograph versus computed tomography-inter-observer and intra-observer reliability.
    Gieroba TJ; Marasco S; Babazadeh S; Di Bella C; van Bavel D
    Arthroplasty; 2023 Aug; 5(1):35. PubMed ID: 37528475
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Interobserver Agreement of Post-operative Perth Computed Tomography Protocol Data in Total Knee Arthroplasty.
    Jones LC; Wood JA; MacDessi SJ
    Cureus; 2023 Jan; 15(1):e34349. PubMed ID: 36865978
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Two-dimensional measurement misidentifies alignment outliers in total knee arthroplasty: a comparison of two- and three-dimensional measurements.
    Ueyama H; Minoda Y; Sugama R; Ohta Y; Yamamura K; Nakamura S; Takemura S; Nakamura H
    Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1497-1503. PubMed ID: 30284009
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Impact of Imaging Modality on the Measurement of Coronal Plane Alignment After Total Knee Arthroplasty.
    Nam D; Vajapey S; Nunley RM; Barrack RL
    J Arthroplasty; 2016 Oct; 31(10):2314-9. PubMed ID: 27067164
    [TBL] [Abstract][Full Text] [Related]  

  • 8. No correlation between coronal alignment of total knee arthroplasty and clinical outcomes: a prospective clinical study using 3D-CT.
    Slevin O; Amsler F; Hirschmann MT
    Knee Surg Sports Traumatol Arthrosc; 2017 Dec; 25(12):3892-3900. PubMed ID: 28005142
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Plain Radiographs Can Safely Be Used to Measure and Follow Up on Tibial Component Alignment in Unicondylar Knee Replacement: A Correlation Study With CT Scans.
    Veizi E; Çay N; Güven Ş; Şahin A; Fırat A; Kılıçarslan K
    Cureus; 2021 Aug; 13(8):e16902. PubMed ID: 34513475
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Can total knee arthroplasty restore the correlation between radiographic mechanical axis angle and dynamic coronal plane alignment during gait?
    Larose G; Fuentes A; Lavoie F; Aissaoui R; de Guise J; Hagemeister N
    Knee; 2019 Jun; 26(3):586-594. PubMed ID: 31047797
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Due to great variability fixed HKS angle for alignment of the distal cut leads to a significant error in coronal TKA orientation.
    Lampart M; Behrend H; Moser LB; Hirschmann MT
    Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1434-1441. PubMed ID: 29961097
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Radiographic outcomes in the coronal plane with iASSIST™ versus optical navigation for total knee arthroplasty: A preliminary case-control study.
    Desseaux A; Graf P; Dubrana F; Marino R; Clavé A
    Orthop Traumatol Surg Res; 2016 May; 102(3):363-8. PubMed ID: 27033838
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Neutral alignment leads to higher knee society scores after total knee arthroplasty in preoperatively non-varus patients: a prospective clinical study using 3D-CT.
    Slevin O; Hirschmann A; Schiapparelli FF; Amsler F; Huegli RW; Hirschmann MT
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1602-1609. PubMed ID: 29026941
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An accelerometer-based portable navigation system improved prosthetic alignment after total knee arthroplasty in 3D measurements.
    Ueyama H; Minoda Y; Sugama R; Ohta Y; Yamamura K; Nakamura S; Takemura S; Nakamura H
    Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1580-1586. PubMed ID: 30066018
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optimization of sagittal and coronal planes with robotic-assisted unicompartmental knee arthroplasty.
    Gaudiani MA; Nwachukwu BU; Baviskar JV; Sharma M; Ranawat AS
    Knee; 2017 Aug; 24(4):837-843. PubMed ID: 28579132
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Assessing Lower Limb Alignment: Comparison of Standard Knee Xray vs Long Leg View.
    Zampogna B; Vasta S; Amendola A; Uribe-Echevarria Marbach B; Gao Y; Papalia R; Denaro V
    Iowa Orthop J; 2015; 35():49-54. PubMed ID: 26361444
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Partially loaded plain radiographic measurement to evaluate rotational alignment in total knee arthroplasty.
    Pedraza W; Beckmann J; Mayer C; Mauch F; Huth J; Best R
    Int Orthop; 2016 Dec; 40(12):2519-2526. PubMed ID: 27447464
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Novel Vector-Based Computer Tomography Alignment Measurement Protocol for Total Knee Arthroplasty.
    Persohn SA; Paramasivam M; Zhang J; Bhowmik-Stoker M; Otto J; Wahdan A; Salem HS; Choplin RH; Territo PR; Mont MA
    Surg Technol Int; 2020 May; 36():371-378. PubMed ID: 32196560
    [TBL] [Abstract][Full Text] [Related]  

  • 19. No impact of under-correction and joint line obliquity on clinical outcomes of total knee arthroplasty for the varus knee.
    Rames RD; Mathison M; Meyer Z; Barrack RL; Nam D
    Knee Surg Sports Traumatol Arthrosc; 2018 May; 26(5):1506-1514. PubMed ID: 28299385
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Distal femoral torsion: comparison of CT scan and intra operative navigation measurements during total knee arthroplasty. A report of 70 cases].
    Galaud B; Beaufils P; Michaut M; Abadie P; Fallet L; Boisrenoult P
    Rev Chir Orthop Reparatrice Appar Mot; 2008 Oct; 94(6):573-9. PubMed ID: 18929752
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.