These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Parathyroid Autofluorescence-How Does It Affect Parathyroid and Thyroid Surgery? A 5 Year Experience. Ladurner R; Lerchenberger M; Al Arabi N; Gallwas JKS; Stepp H; Hallfeldt KKJ Molecules; 2019 Jul; 24(14):. PubMed ID: 31337096 [TBL] [Abstract][Full Text] [Related]
4. A multicenter evaluation of near-infrared autofluorescence imaging of parathyroid glands in thyroid and parathyroid surgery. Sehnem L; Noureldine SI; Avci S; Isiktas G; Elshamy M; Saito Y; Ahmed AHA; Tierney HT; Trinh LN; Karcioglu AS; Cheung AY; Otremba M; Krishnamurthy V; Heiden K; Jin J; Shin J; Siperstein A; Zafereo M; Tufano RP; Randolph GW; Kebebew E; Milas M; Duh QY; Berber E Surgery; 2023 Jan; 173(1):132-137. PubMed ID: 36511281 [TBL] [Abstract][Full Text] [Related]
5. Autofluorescence imaging of parathyroid glands: An assessment of potential indications. Kose E; Rudin AV; Kahramangil B; Moore E; Aydin H; Donmez M; Krishnamurthy V; Siperstein A; Berber E Surgery; 2020 Jan; 167(1):173-179. PubMed ID: 31526579 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of Autofluorescence in Identifying Parathyroid Glands by Measuring Parathyroid Hormone in Fine-Needle Biopsy Washings. Liu Z; Ma RS; Jia JL; Wang T; Zuo DH; Yin DT Front Endocrinol (Lausanne); 2021; 12():819503. PubMed ID: 35126316 [TBL] [Abstract][Full Text] [Related]
7. Intraoperative detection of parathyroid glands by autofluorescence identification using image-based system: report of 15 cases. Gorobeiko M; Dinets A J Med Case Rep; 2021 Aug; 15(1):414. PubMed ID: 34365979 [TBL] [Abstract][Full Text] [Related]
8. Detectable depth of unexposed parathyroid glands using near-infrared autofluorescence imaging in thyroid surgery. Han YS; Kim Y; Lee HS; Kim Y; Ahn YC; Lee KD Front Endocrinol (Lausanne); 2023; 14():1170751. PubMed ID: 37113485 [TBL] [Abstract][Full Text] [Related]
9. [Clinical application of parathyroid autofluorescence imaging in endoscopic thyroid surgery]. Sun J; Guo L; Kang J; Tao Y; Wang J Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2023 Oct; 37(10):832-836. PubMed ID: 37828890 [No Abstract] [Full Text] [Related]
10. The utility of parathyroid autofluorescence as an adjunct in thyroid and parathyroid surgery 2023. Pace-Asciak P; Russell J; Solorzano C; Berber E; Singer M; Shaha AR; Khafif A; Angelos P; Nixon I; Tufano RP Head Neck; 2023 Dec; 45(12):3157-3167. PubMed ID: 37807364 [TBL] [Abstract][Full Text] [Related]
11. The Accuracy of Near Infrared Autofluorescence in Identifying Parathyroid Gland During Thyroid and Parathyroid Surgery: A Meta-Analysis. Wang B; Zhu CR; Liu H; Yao XM; Wu J Front Endocrinol (Lausanne); 2021; 12():701253. PubMed ID: 34234746 [TBL] [Abstract][Full Text] [Related]
12. Spare Parathyroid Glands During Thyroid Surgery with Perioperative Autofluorescence Imaging: A Diagnostic Study. Bellier A; Wazne Y; Chollier T; Sturm N; Chaffanjon P World J Surg; 2021 Sep; 45(9):2785-2790. PubMed ID: 33835219 [TBL] [Abstract][Full Text] [Related]
13. Randomized Controlled Trial Comparing White Light with Near-Infrared Autofluorescence for Parathyroid Gland Identification During Total Thyroidectomy. Dip F; Falco J; Verna S; Prunello M; Loccisano M; Quadri P; White K; Rosenthal R J Am Coll Surg; 2019 May; 228(5):744-751. PubMed ID: 30710614 [TBL] [Abstract][Full Text] [Related]
14. Near-Infrared Autofluorescence Image-Guided Parathyroid Gland Mapping in Thyroidectomy. Kim SW; Lee HS; Ahn YC; Park CW; Jeon SW; Kim CH; Ko JB; Oak C; Kim Y; Lee KD J Am Coll Surg; 2018 Feb; 226(2):165-172. PubMed ID: 29122718 [TBL] [Abstract][Full Text] [Related]
15. [Application of near-infrared autofluorescence imaging-based convolution neural network in recognition of parathyroid gland]. He YR; Li ZF; Zhong Q; Wang Y; Wang XY; Huang JW; Huang ZG; Fang JG Zhonghua Yi Xue Za Zhi; 2023 Oct; 103(40):3193-3198. PubMed ID: 37879873 [No Abstract] [Full Text] [Related]
16. Real-time intraoperative near-infrared autofluorescence imaging to locate the parathyroid glands: A preliminary report. Qian B; Zhang X; Bing K; Hu L; Qu X; Huang T; Shi W; Zhang S Biosci Trends; 2022 Sep; 16(4):301-306. PubMed ID: 35768258 [TBL] [Abstract][Full Text] [Related]
17. Autofluorescence-guided hemithyroidectomy in a low-volume thyroid institution with no experience in parathyroid surgery: randomized clinical trial. Abood A; Rolighed L; Ovesen T; Madsen SH; Vestergaard P; Triponez F Br J Surg; 2024 Apr; 111(4):. PubMed ID: 38573333 [TBL] [Abstract][Full Text] [Related]
18. Parathyroid gland detection using an intraoperative autofluorescence handheld imager - early feasibility study. Ali KM; Wolfe SA; Nagururu NV; Seo S; Han SM; Kim Y; Oh E; Kim DY; Ning B; Lee SY; Cha RJ; Tufano RP; Russell JO Front Endocrinol (Lausanne); 2023; 14():1190282. PubMed ID: 37554762 [TBL] [Abstract][Full Text] [Related]
19. Enhancing Parathyroid Gland Visualization Using a Near Infrared Fluorescence-Based Overlay Imaging System. McWade MA; Thomas G; Nguyen JQ; Sanders ME; Solórzano CC; Mahadevan-Jansen A J Am Coll Surg; 2019 May; 228(5):730-743. PubMed ID: 30769112 [TBL] [Abstract][Full Text] [Related]
20. Impact of near-infrared fluorescence imaging plus indocyanine green fluorescence on postoperative hypoparathyroidism rates after total thyroidectomy and central neck lymph node dissection. Di Lorenzo S; Carrillo Lizarazo JL; Dionigi G; Kraimps JL; Donatini G Br J Surg; 2024 Jan; 111(2):. PubMed ID: 38381933 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]