These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
197 related articles for article (PubMed ID: 29028403)
1. Laser ion mobility spectrometry in the detection of ultra-low quantities of explosives. Akmalov AE; Chistyakov AA; Kotkovskii GE; Martynov IL; Spitsin EM Eur J Mass Spectrom (Chichester); 2017 Aug; 23(4):140-145. PubMed ID: 29028403 [TBL] [Abstract][Full Text] [Related]
2. Detection of explosives in vapor phase by field asymmetric ion mobility spectrometry with dopant-assisted laser ionization. Kostarev VA; Kotkovskii GE; Chistyakov AA; Akmalov AE Talanta; 2022 Aug; 245():123414. PubMed ID: 35487080 [TBL] [Abstract][Full Text] [Related]
3. Analysis of explosives using corona discharge ionization combined with ion mobility spectrometry-mass spectrometry. Lee J; Park S; Cho SG; Goh EM; Lee S; Koh SS; Kim J Talanta; 2014 Mar; 120():64-70. PubMed ID: 24468343 [TBL] [Abstract][Full Text] [Related]
4. Integration of paper spray ionization high-field asymmetric waveform ion mobility spectrometry for forensic applications. Tsai CW; Tipple CA; Yost RA Rapid Commun Mass Spectrom; 2018 Apr; 32(7):552-560. PubMed ID: 29380926 [TBL] [Abstract][Full Text] [Related]
5. Tandem Ion Mobility Spectrometry for the Detection of Traces of Explosives in Cargo at Concentrations of Parts Per Quadrillion. Amo-González M; Pérez S; Delgado R; Arranz G; Carnicero I Anal Chem; 2019 Nov; 91(21):14009-14018. PubMed ID: 31556599 [TBL] [Abstract][Full Text] [Related]
6. Dopant-assisted negative photoionization ion mobility spectrometry for sensitive detection of explosives. Cheng S; Dou J; Wang W; Chen C; Hua L; Zhou Q; Hou K; Li J; Li H Anal Chem; 2013 Jan; 85(1):319-26. PubMed ID: 23199155 [TBL] [Abstract][Full Text] [Related]
7. Detection of explosives by positive corona discharge ion mobility spectrometry. Tabrizchi M; Ilbeigi V J Hazard Mater; 2010 Apr; 176(1-3):692-6. PubMed ID: 20004055 [TBL] [Abstract][Full Text] [Related]
8. Precise determination of nonlinear function of ion mobility for explosives and drugs at high electric fields for microchip FAIMS. Guo D; Wang Y; Li L; Wang X; Luo J J Mass Spectrom; 2015 Jan; 50(1):198-205. PubMed ID: 25601693 [TBL] [Abstract][Full Text] [Related]
10. Direct detection of explosives on solid surfaces by low temperature plasma desorption mass spectrometry. Zhang Y; Ma X; Zhang S; Yang C; Ouyang Z; Zhang X Analyst; 2009 Jan; 134(1):176-81. PubMed ID: 19082190 [TBL] [Abstract][Full Text] [Related]
11. Rapid on-site detection of explosives on surfaces by ambient pressure laser desorption and direct inlet single photon ionization or chemical ionization mass spectrometry. Ehlert S; Hölzer J; Rittgen J; Pütz M; Schulte-Ladbeck R; Zimmermann R Anal Bioanal Chem; 2013 Sep; 405(22):6979-93. PubMed ID: 23455645 [TBL] [Abstract][Full Text] [Related]
12. Attogram sensing of trinitrotoluene with a self-assembled molecular gelator. Kartha KK; Babu SS; Srinivasan S; Ajayaghosh A J Am Chem Soc; 2012 Mar; 134(10):4834-41. PubMed ID: 22352376 [TBL] [Abstract][Full Text] [Related]
13. Micro-solid-phase extraction coupled to desorption electrospray ionization-high-resolution mass spectrometry for the analysis of explosives in soil. Bianchi F; Gregori A; Braun G; Crescenzi C; Careri M Anal Bioanal Chem; 2015 Jan; 407(3):931-8. PubMed ID: 25277104 [TBL] [Abstract][Full Text] [Related]
14. Detection of explosives in hair using ion mobility spectrometry. Oxley JC; Smith JL; Kirschenbaum LJ; Marimganti S; Vadlamannati S J Forensic Sci; 2008 May; 53(3):690-3. PubMed ID: 18471216 [TBL] [Abstract][Full Text] [Related]
15. Dynamic planar solid phase microextraction-ion mobility spectrometry for rapid field air sampling and analysis of illicit drugs and explosives. Guerra-Diaz P; Gura S; Almirall JR Anal Chem; 2010 Apr; 82(7):2826-35. PubMed ID: 20205382 [TBL] [Abstract][Full Text] [Related]
16. Increasing selectivity for TNT-based explosive detection by synchronous luminescence and derivative spectroscopy with quantum yields of selected aromatic amines. Sheaff CN; Eastwood D; Wai CM Appl Spectrosc; 2007 Jan; 61(1):68-73. PubMed ID: 17311719 [TBL] [Abstract][Full Text] [Related]
17. Instant visual detection of picogram levels of trinitrotoluene by using luminescent metal-organic framework gel-coated filter paper. Lee JH; Kang S; Lee JY; Jaworski J; Jung JH Chemistry; 2013 Dec; 19(49):16665-71. PubMed ID: 24203392 [TBL] [Abstract][Full Text] [Related]
18. Detection of explosives using negative ion mobility spectrometry in air based on dopant-assisted thermal ionization. Shahraki H; Tabrizchi M; Farrokhpor H J Hazard Mater; 2018 Sep; 357():1-9. PubMed ID: 29859459 [TBL] [Abstract][Full Text] [Related]
19. UV-FIA: UV-induced fluoro-immunochemical assay for ultra-trace detection of PETN, RDX, and TNT. Chaudhary S; Sonkusre P; Chopra A; Bhasin KK; Suri CR Anal Chim Acta; 2019 Oct; 1077():266-272. PubMed ID: 31307718 [TBL] [Abstract][Full Text] [Related]