These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

215 related articles for article (PubMed ID: 29028426)

  • 21. A portable optical reader and wall projector towards enumeration of bio-conjugated beads or cells.
    Glynn MT; Kinahan DJ; McArdle NA; Kendlin JL; O'Connell TM; Ducrée J
    PLoS One; 2017; 12(12):e0189923. PubMed ID: 29267367
    [TBL] [Abstract][Full Text] [Related]  

  • 22. CD4+ T lymphocytes enumeration by an easy-to-use single platform image cytometer for HIV monitoring in resource-constrained settings.
    Li X; Ymeti A; Lunter B; Breukers C; Tibbe AG; Terstappen LW; Greve J
    Cytometry B Clin Cytom; 2007 Sep; 72(5):397-407. PubMed ID: 17311352
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Integration of semiconductor quantum dots into nano-bio-chip systems for enumeration of CD4+ T cell counts at the point-of-need.
    Jokerst JV; Floriano PN; Christodoulides N; Simmons GW; McDevitt JT
    Lab Chip; 2008 Dec; 8(12):2079-90. PubMed ID: 19023471
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A polymer lab-on-a-chip for magnetic immunoassay with on-chip sampling and detection capabilities.
    Do J; Ahn CH
    Lab Chip; 2008 Apr; 8(4):542-9. PubMed ID: 18369508
    [TBL] [Abstract][Full Text] [Related]  

  • 25. High-throughput microfluidic device for single cell analysis using multiple integrated soft lithographic pumps.
    Patabadige DE; Mickleburgh T; Ferris L; Brummer G; Culbertson AH; Culbertson CT
    Electrophoresis; 2016 May; 37(10):1337-44. PubMed ID: 26887846
    [TBL] [Abstract][Full Text] [Related]  

  • 26. An automated and portable microfluidic chemiluminescence immunoassay for quantitative detection of biomarkers.
    Hu B; Li J; Mou L; Liu Y; Deng J; Qian W; Sun J; Cha R; Jiang X
    Lab Chip; 2017 Jun; 17(13):2225-2234. PubMed ID: 28573279
    [TBL] [Abstract][Full Text] [Related]  

  • 27. An automated microfluidic chemiluminescence immunoassay platform for quantitative detection of biomarkers.
    Min X; Fu D; Zhang J; Zeng J; Weng Z; Chen W; Zhang S; Zhang D; Ge S; Zhang J; Xia N
    Biomed Microdevices; 2018 Oct; 20(4):91. PubMed ID: 30361769
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Microfluidic magnetic fluidized bed for DNA analysis in continuous flow mode.
    Hernández-Neuta I; Pereiro I; Ahlford A; Ferraro D; Zhang Q; Viovy JL; Descroix S; Nilsson M
    Biosens Bioelectron; 2018 Apr; 102():531-539. PubMed ID: 29216580
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A complementary method to CD4 counting: measurement of CD4+/CD8+ T lymphocyte ratio in a tandem affinity microfluidic system.
    Li W; Gao Y; Pappas D
    Biomed Microdevices; 2015 Dec; 17(6):113. PubMed ID: 26559198
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Lyophilization of chemiluminescent substrate reagents for high-sensitive microchannel-based lateral flow assay (MLFA) in point-of-care (POC) diagnostic system.
    Ghosh S; Ahn CH
    Analyst; 2019 Mar; 144(6):2109-2119. PubMed ID: 30741267
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Rotation-Driven Microfluidic Disc for White Blood Cell Enumeration Using Magnetic Bead Aggregation.
    Ouyang Y; Li J; Haverstick DM; Landers JP
    Anal Chem; 2016 Nov; 88(22):11046-11054. PubMed ID: 27779404
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A flow-through cell counting assay for point-of-care enumeration of CD4 T-cells.
    Bystryak S; Bandwar RP; Santockyte R
    J Virol Methods; 2019 Sep; 271():113672. PubMed ID: 31145920
    [TBL] [Abstract][Full Text] [Related]  

  • 33. On-chip sample preparation by controlled release of antibodies for simple CD4 counting.
    Beck M; Brockhuis S; van der Velde N; Breukers C; Greve J; Terstappen LW
    Lab Chip; 2012 Jan; 12(1):167-73. PubMed ID: 22048158
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Coincidence detection of heterogeneous cell populations from whole blood with coplanar electrodes in a microfluidic impedance cytometer.
    Hassan U; Bashir R
    Lab Chip; 2014 Nov; 14(22):4370-81. PubMed ID: 25231594
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A microfluidic system for rapid nucleic acid analysis based on real-time convective PCR at point-of-care testing.
    Xu D; Jiang X; Zou T; Miao G; Fu Q; Xiang F; Feng L; Ye X; Zhang L; Qiu X
    Microfluid Nanofluidics; 2022; 26(9):69. PubMed ID: 35991118
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A hinge-based aligner for fast, large-scale assembly of microfluidic chips.
    Mou L; Hu B; Zhang J; Jiang X
    Biomed Microdevices; 2019 Jul; 21(3):69. PubMed ID: 31273551
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Perfect count: a novel approach for the single platform enumeration of absolute CD4+ T-lymphocytes.
    Storie I; Sawle A; Goodfellow K; Whitby L; Granger V; Ward RY; Peel J; Smart T; Reilly JT; Barnett D
    Cytometry B Clin Cytom; 2004 Jan; 57(1):47-52. PubMed ID: 14696063
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Magnetic bead droplet immunoassay of oligomer amyloid β for the diagnosis of Alzheimer's disease using micro-pillars to enhance the stability of the oil-water interface.
    Kim JA; Kim M; Kang SM; Lim KT; Kim TS; Kang JY
    Biosens Bioelectron; 2015 May; 67():724-32. PubMed ID: 25459055
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Bead-based microfluidic immunoassay for diagnosis of Johne's disease.
    Wadhwa A; Foote RS; Shaw RW; Eda S
    J Immunol Methods; 2012 Aug; 382(1-2):196-202. PubMed ID: 22705087
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Integrated electrokinetic magnetic bead-based electrochemical immunoassay on microfluidic chips for reliable control of permitted levels of zearalenone in infant foods.
    Hervás M; López MA; Escarpa A
    Analyst; 2011 May; 136(10):2131-8. PubMed ID: 21394379
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.