These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
319 related articles for article (PubMed ID: 29030033)
1. A low-cost biosorbent-based coating for the highly sensitive determination of organochlorine pesticides by solid-phase microextraction and gas chromatography-electron capture detection. do Carmo SN; Merib J; Dias AN; Stolberg J; Budziak D; Carasek E J Chromatogr A; 2017 Nov; 1525():23-31. PubMed ID: 29030033 [TBL] [Abstract][Full Text] [Related]
2. Use of green coating (cork) in solid-phase microextraction for the determination of organochlorine pesticides in water by gas chromatography-electron capture detection. Neves Dias A; Simão V; Merib J; Carasek E Talanta; 2015 Mar; 134():409-414. PubMed ID: 25618687 [TBL] [Abstract][Full Text] [Related]
3. A novel graphene nanosheets coated stainless steel fiber for microwave assisted headspace solid phase microextraction of organochlorine pesticides in aqueous samples followed by gas chromatography with electron capture detection. Ponnusamy VK; Jen JF J Chromatogr A; 2011 Sep; 1218(39):6861-8. PubMed ID: 21872868 [TBL] [Abstract][Full Text] [Related]
4. Exploring the use of cork pellets in bar adsorptive microextraction for the determination of organochloride pesticides in water samples with gas chromatography/electron capture detection quantification. Hinz JS; Morés L; Carasek E J Chromatogr A; 2021 May; 1645():462099. PubMed ID: 33848658 [TBL] [Abstract][Full Text] [Related]
5. Preparation of graphene-coated solid-phase microextraction fiber and its application on organochlorine pesticides determination. Ke Y; Zhu F; Zeng F; Luan T; Su C; Ouyang G J Chromatogr A; 2013 Jul; 1300():187-92. PubMed ID: 23261291 [TBL] [Abstract][Full Text] [Related]
6. Water with low concentration of surfactant in dispersed solvent-assisted emulsion dispersive liquid-liquid microextraction for the determination of organochlorine pesticides in aqueous samples. Li Y; Chen PS; Huang SD J Chromatogr A; 2013 Jul; 1300():51-7. PubMed ID: 23566919 [TBL] [Abstract][Full Text] [Related]
7. Nano-structured polyaniline-ionic liquid composite film coated steel wire for headspace solid-phase microextraction of organochlorine pesticides in water. Gao Z; Li W; Liu B; Liang F; He H; Yang S; Sun C J Chromatogr A; 2011 Sep; 1218(37):6285-91. PubMed ID: 21821255 [TBL] [Abstract][Full Text] [Related]
8. Preparation of porous aromatic framework/ionic liquid hybrid composite coated solid-phase microextraction fibers and their application in the determination of organochlorine pesticides combined with GC-ECD detection. Wu M; Chen G; Liu P; Zhou W; Jia Q Analyst; 2016 Jan; 141(1):243-50. PubMed ID: 26579991 [TBL] [Abstract][Full Text] [Related]
9. Application of ultrasound-assisted emulsification microextraction based on applying low-density organic solvent for the determination of organochlorine pesticides in water samples. Zhang Y; Lee HK J Chromatogr A; 2012 Aug; 1252():67-73. PubMed ID: 22771061 [TBL] [Abstract][Full Text] [Related]
10. Development of an analytical methodology for the determination of organochlorine pesticides by ethylene-vinyl acetate passive samplers in marine surface waters based on ultrasound-assisted solvent extraction followed with headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry. Cárdenas-Soracá DM; Tucca FI; Mardones-Peña CA; Barra-Ríos RO J Chromatogr A; 2019 Nov; 1605():360341. PubMed ID: 31395356 [TBL] [Abstract][Full Text] [Related]
11. Substrateless graphene fiber: a sorbent for solid-phase microextraction. Luo YB; Yuan BF; Yu QW; Feng YQ J Chromatogr A; 2012 Dec; 1268():9-15. PubMed ID: 23131764 [TBL] [Abstract][Full Text] [Related]
12. Electrodeposited polyaniline as a fiber coating for solid-phase microextraction of organochlorine pesticides from water. Li X; Zhong M; Chen J J Sep Sci; 2008 Aug; 31(15):2839-45. PubMed ID: 18655018 [TBL] [Abstract][Full Text] [Related]
13. Ultra trace analysis of 17 organochlorine pesticides in water samples from the Arctic based on the combination of solid-phase extraction and headspace solid-phase microextraction-gas chromatography-electron-capture detector. Qiu C; Cai M J Chromatogr A; 2010 Feb; 1217(8):1191-202. PubMed ID: 20034632 [TBL] [Abstract][Full Text] [Related]
14. Metal-organic framework-199/graphite oxide hybrid composites coated solid-phase microextraction fibers coupled with gas chromatography for determination of organochlorine pesticides from complicated samples. Zhang S; Du Z; Li G Talanta; 2013 Oct; 115():32-9. PubMed ID: 24054558 [TBL] [Abstract][Full Text] [Related]
15. New magnetic oil palm fiber activated carbon-reinforced polypyrrole solid phase extraction combined with gas chromatography-electron capture detection for determination of organochlorine pesticides in water samples. Marsin FM; Wan Ibrahim WA; Nodeh HR; Sanagi MM J Chromatogr A; 2020 Feb; 1612():460638. PubMed ID: 31676087 [TBL] [Abstract][Full Text] [Related]
16. Determination of organochlorine pesticides and their derivations in water after HS-SPME using polymethylphenylvinylsiloxane-coated fiber by GC-ECD. Dong C; Zeng Z; Yang M Water Res; 2005 Oct; 39(17):4204-10. PubMed ID: 16198393 [TBL] [Abstract][Full Text] [Related]
17. Simultaneous determination of traces of pyrethroids, organochlorines and other main plant protection agents in agricultural soils by headspace solid-phase microextraction-gas chromatography. Fernandez-Alvarez M; Llompart M; Lamas JP; Lores M; Garcia-Jares C; Cela R; Dagnac T J Chromatogr A; 2008 Apr; 1188(2):154-63. PubMed ID: 18346746 [TBL] [Abstract][Full Text] [Related]
18. Hierarchical Graphene coating for highly sensitive solid phase microextraction of organochlorine pesticides. Wang F; Liu S; Yang H; Zheng J; Qiu J; Xu J; Tong Y; Zhu F; Ouyang G Talanta; 2016 Nov; 160():217-224. PubMed ID: 27591607 [TBL] [Abstract][Full Text] [Related]
19. Determination of organochlorine pesticides in ground water samples using solid-phase microextraction by gas chromatography-electron capture detection. Raposo Júnior JL; Ré-Poppi N Talanta; 2007 Jul; 72(5):1833-41. PubMed ID: 19071840 [TBL] [Abstract][Full Text] [Related]
20. Simultaneous analysis of polychlorinated biphenyls and organochlorine pesticides in water by headspace solid-phase microextraction with gas chromatography-tandem mass spectrometry. Derouiche A; Driss MR; Morizur JP; Taphanel MH J Chromatogr A; 2007 Jan; 1138(1-2):231-43. PubMed ID: 17113095 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]