1. CONSTRUCTION AND TEST OF A PORTABLE TISSUE-EQUIVALENT PROPORTIONAL COUNTER SYSTEM.
Zhang W; Ni N; Wang Z; Liu Y; Li C; Luo H
Radiat Prot Dosimetry; 2018 Apr; 179(1):95-100. PubMed ID: 29040775
[TBL] [Abstract][Full Text] [Related]
2. TEPC performance for a reference standard.
Zhang W; Wang Z; Liu Y; Li C; Xiao X; Luo H; Chen J; Li W
Radiat Prot Dosimetry; 2014 Jan; 158(2):246-50. PubMed ID: 24036657
[TBL] [Abstract][Full Text] [Related]
3. Microdosimetric Measurements in Gamma and neutron Fields with a Tissue Equivalent Proportional Counter Based on a Gas Electron Multiplier.
De Nardo L; Dal Corso F; Pegoraro M
Radiat Prot Dosimetry; 2017 Jun; 175(2):260-266. PubMed ID: 27881795
[TBL] [Abstract][Full Text] [Related]
4. Design and simulation of a GEM-based TEPC as a neutron REM meter.
Wang CK; Seidaliev M; Mandapaka AK
Radiat Prot Dosimetry; 2007; 126(1-4):559-63. PubMed ID: 17502312
[TBL] [Abstract][Full Text] [Related]
5. Intercomparison of Monte Carlo radiation transport codes to model TEPC response in low-energy neutron and gamma-ray fields.
Ali F; Waker AJ; Waller EJ
Radiat Prot Dosimetry; 2014 Oct; 161(1-4):257-60. PubMed ID: 24162375
[TBL] [Abstract][Full Text] [Related]
6. THE RESPONSE OF A MULTI-ELEMENT TISSUE EQUIVALENT PROPORTIONAL COUNTER IN ACCELERATOR BASED HIGH-ALTITUDE NEUTRON FIELDS.
Orchard GM; Waker AJ
Radiat Prot Dosimetry; 2018 Aug; 180(1-4):142-145. PubMed ID: 29036384
[TBL] [Abstract][Full Text] [Related]
7. Neutron microdosimetric response of a gas electron multiplier.
Dubeau J; Waker AJ
Radiat Prot Dosimetry; 2008; 128(4):413-20. PubMed ID: 17951607
[TBL] [Abstract][Full Text] [Related]
8. Long-term measurements of H*(10) at aviation altitudes in the northern hemisphere.
Wissmann F
Radiat Prot Dosimetry; 2006; 121(4):347-57. PubMed ID: 16698966
[TBL] [Abstract][Full Text] [Related]
9. A NOVEL TEPC FOR MICRODOSIMETRY AT NANOMETRIC LEVEL: RESPONSE AGAINST DIFFERENT NEUTRON FIELDS.
Bortot D; Mazzucconi D; Bonfanti M; Agosteo S; Pola A; Pasquato S; Fazzi A; Colautti P; Conte V
Radiat Prot Dosimetry; 2018 Aug; 180(1-4):172-176. PubMed ID: 29036508
[TBL] [Abstract][Full Text] [Related]
10. Sensitivity and uncertainty in the measurement of H*(10) in neutron fields using an REM500 and a multi-element TEPC.
Waker A; Taylor G
Radiat Prot Dosimetry; 2014 Oct; 161(1-4):205-9. PubMed ID: 24711528
[TBL] [Abstract][Full Text] [Related]
11. DEVELOPMENT OF HETEROGENEOUS PROPORTIONAL COUNTERS FOR NEUTRON DOSIMETRY.
Forouzan F; Waker AJ
Radiat Prot Dosimetry; 2018 Aug; 180(1-4):168-171. PubMed ID: 29329450
[TBL] [Abstract][Full Text] [Related]
12. Design of a multi-element TEPC for neutron monitoring.
Waker AJ; Aslam ; Lori J
Radiat Prot Dosimetry; 2011 Feb; 143(2-4):463-6. PubMed ID: 21186210
[TBL] [Abstract][Full Text] [Related]
13. Preliminary results on bubble detector as personal neutron dosemeter.
Ponraju D; Krishnan H; Viswanathan S; Indira R
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):177-81. PubMed ID: 21217133
[TBL] [Abstract][Full Text] [Related]
14. Development of an advanced two-dimensional microdosimetric detector based on THick Gas Electron Multipliers.
Darvish-Molla S; Prestwich WV; Byun SH
Med Phys; 2018 Mar; 45(3):1241-1254. PubMed ID: 29344955
[TBL] [Abstract][Full Text] [Related]
15. An active personal neutron dosemeter based on microdosimetric principles: CIME.
Ménard S; Cutarella D; Lahaye T; Bolognese-Milsztajn T
Radiat Prot Dosimetry; 2001; 96(1-3):265-8. PubMed ID: 11586745
[TBL] [Abstract][Full Text] [Related]
16. Response of a tissue equivalent proportional counter to neutrons.
Badhwar GD; Robbins DE; Gibbons F; Braby LA
Radiat Meas; 2002 Dec; 35(6):551-6. PubMed ID: 12455500
[TBL] [Abstract][Full Text] [Related]
17. The neutron component of two high-energy photon reference fields.
Röttger S; Schäler K; Behrens R; Nolte R; Wissmann F
Radiat Prot Dosimetry; 2007; 126(1-4):404-7. PubMed ID: 17675300
[TBL] [Abstract][Full Text] [Related]
18. Differential absorbed dose distributions in lineal energy for neutrons and gamma rays at the mono-energetic neutron calibration facility.
Takada M; Baba M; Yamaguchi H; Fujitaka K
Radiat Prot Dosimetry; 2005; 114(4):481-90. PubMed ID: 15914511
[TBL] [Abstract][Full Text] [Related]
19. First microdosimetric measurements with a TEPC based on a GEM.
Farahmand M; Bos AJ; De Nardo L; van Eijk CW
Radiat Prot Dosimetry; 2004; 110(1-4):839-43. PubMed ID: 15353756
[TBL] [Abstract][Full Text] [Related]
20. Simulation and calibration of an active neutron dosemeter.
Bergmeier F; Volnhals M; Wielunski M; Rühm W
Radiat Prot Dosimetry; 2014 Oct; 161(1-4):126-9. PubMed ID: 24368869
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]