These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
101 related articles for article (PubMed ID: 29047793)
1. Adaptive measurement method for miniature spectrometers used in cold environments. Wang H; Nan L; Huang H; Yang P; Song H; Han J; Wu Y; Yan T; Yuan Z; Chen Y Appl Opt; 2017 Oct; 56(28):8029-8039. PubMed ID: 29047793 [TBL] [Abstract][Full Text] [Related]
2. Correcting temperature dependence in miniature spectrometers used in cold polar environments. Wang H; Song H; Chen Y; Laney SR Appl Opt; 2015 Apr; 54(11):3162-72. PubMed ID: 25967300 [TBL] [Abstract][Full Text] [Related]
3. Temperature and nonlinearity corrections for a photodiode array spectrometer used in the field. Salim SG; Fox NP; Theocharous E; Sun T; Grattan KT Appl Opt; 2011 Feb; 50(6):866-75. PubMed ID: 21343966 [TBL] [Abstract][Full Text] [Related]
5. An Improved Method for Accurate Radiation Measurement Based on Dark Output Noise Drift Compensation. Zhao B; Zhang K; Yu Y; Yu K; Liu Y Sensors (Basel); 2023 Jul; 23(13):. PubMed ID: 37448006 [TBL] [Abstract][Full Text] [Related]
6. [Optical Design of Miniature Infrared Gratings Spectrometer Based on Planar Waveguide]. Li YY; Fang YH; Li DC; Liu Y Guang Pu Xue Yu Guang Pu Fen Xi; 2015 Mar; 35(3):841-5. PubMed ID: 26117908 [TBL] [Abstract][Full Text] [Related]
12. Responses of cutaneous A-fiber nociceptors to noxious cold. Simone DA; Kajander KC J Neurophysiol; 1997 Apr; 77(4):2049-60. PubMed ID: 9114254 [TBL] [Abstract][Full Text] [Related]
13. Noise analysis of spectrometers based on speckle pattern reconstruction. Redding B; Popoff SM; Bromberg Y; Choma MA; Cao H Appl Opt; 2014 Jan; 53(3):410-7. PubMed ID: 24514126 [TBL] [Abstract][Full Text] [Related]
14. Single-sequence stable spectroscopic reflectometry using simultaneous measurement of incident light and reflected light. Lee SY; Lee SW; Choi G; Cho Y; Pahk HJ Appl Opt; 2021 Oct; 60(28):8915-8921. PubMed ID: 34613120 [TBL] [Abstract][Full Text] [Related]
15. High-pressure stopped-flow spectrometer for kinetic studies of fast reactions by absorbance and fluorescence detection. Bugnon P; Laurenczy G; Ducommun Y; Sauvageat PY; Merbach AE; Ith R; Tschanz R; Doludda M; Bergbauer R; Grell E Anal Chem; 1996 Sep; 68(17):3045-9. PubMed ID: 21619372 [TBL] [Abstract][Full Text] [Related]
16. Study on error calibration of fiber optic gyroscope under intense ambient temperature variation. Chen X; Shen C Appl Opt; 2012 Jun; 51(17):3755-62. PubMed ID: 22695652 [TBL] [Abstract][Full Text] [Related]
17. Modulated FT-Raman Fiber-Optic Spectroscopy: A Technique for Remotely Monitoring High-Temperature Reactions in Real-Time. Cooper JB; Wise KL; Jensen BJ Anal Chem; 1997 Jun; 69(11):1973-8. PubMed ID: 21639237 [TBL] [Abstract][Full Text] [Related]
18. Evaluation of miniature data loggers for body temperature measurement during sporting activities. Fuller A; Oosthuyse T; Maloney SK; Mitchell D Eur J Appl Physiol Occup Physiol; 1999 Mar; 79(4):341-6. PubMed ID: 10090634 [TBL] [Abstract][Full Text] [Related]
19. Development of a low power miniature linear ion trap mass spectrometer with extended mass range. Li G; Li D; Cheng Y; Pei X; Zhang H; Wang Y; Sun J; Dong M Rev Sci Instrum; 2017 Dec; 88(12):123108. PubMed ID: 29289174 [TBL] [Abstract][Full Text] [Related]
20. Ambient ionization and miniature mass spectrometry system for chemical and biological analysis. Ma X; Ouyang Z Trends Analyt Chem; 2016 Dec; 85(A):10-19. PubMed ID: 28042191 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]