BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

624 related articles for article (PubMed ID: 29050625)

  • 1. Multicenter Comparison of Novel Self-Expanding Versus Balloon-Expandable Transcatheter Heart Valves.
    Husser O; Kim WK; Pellegrini C; Holzamer A; Walther T; Mayr PN; Joner M; Kasel AM; Trenkwalder T; Michel J; Rheude T; Kastrati A; Schunkert H; Burgdorf C; Hilker M; Möllmann H; Hengstenberg C
    JACC Cardiovasc Interv; 2017 Oct; 10(20):2078-2087. PubMed ID: 29050625
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transcatheter Aortic Valve Replacement With Next-Generation Self-Expanding Devices: A Multicenter, Retrospective, Propensity-Matched Comparison of Evolut PRO Versus Acurate neo Transcatheter Heart Valves.
    Pagnesi M; Kim WK; Conradi L; Barbanti M; Stefanini GG; Zeus T; Pilgrim T; Schofer J; Zweiker D; Testa L; Taramasso M; Hildick-Smith D; Abizaid A; Wolf A; Van Mieghem NM; Sedaghat A; Wöhrle J; Khogali S; Van der Heyden JAS; Webb JG; Estévez-Loureiro R; Mylotte D; MacCarthy P; Brugaletta S; Hamm CW; Bhadra OD; Schäfer U; Costa G; Tamburino C; Cannata F; Reimers B; Veulemans V; Asami M; Windecker S; Eitan A; Schmidt A; Bianchi G; Bedogni F; Saccocci M; Maisano F; Alsanjari O; Siqueira D; Jensen CJ; Naber CK; Ziviello F; Sinning JM; Seeger J; Rottbauer W; Brouwer J; Alenezi A; Wood DA; Tzalamouras V; Regueiro A; Colombo A; Latib A
    JACC Cardiovasc Interv; 2019 Mar; 12(5):433-443. PubMed ID: 30846081
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bioprosthetic Valve Performance After Transcatheter Aortic Valve Replacement With Self-Expanding Versus Balloon-Expandable Valves in Large Versus Small Aortic Valve Annuli: Insights From the CHOICE Trial and the CHOICE-Extend Registry.
    Abdelghani M; Mankerious N; Allali A; Landt M; Kaur J; Sulimov DS; Merten C; Sachse S; Mehilli J; Neumann FJ; Frerker C; Kurz T; El-Mawardy M; Richardt G; Abdel-Wahab M
    JACC Cardiovasc Interv; 2018 Dec; 11(24):2507-2518. PubMed ID: 30503595
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Outcomes of transfemoral balloon expandable transcatheter aortic valve implantation: Comparison of two subsequent valve generations.
    Schymik G; Wendler O; Hengstenberg C; Ohlmann P; Gilard M; Digne F; Souteyrand G; Letocart V; van Belle E; Bramlage P; Tarantini G;
    Catheter Cardiovasc Interv; 2020 Oct; 96(4):930-939. PubMed ID: 31794159
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 5-Year Outcomes After TAVR With Balloon-Expandable Versus Self-Expanding Valves: Results From the CHOICE Randomized Clinical Trial.
    Abdel-Wahab M; Landt M; Neumann FJ; Massberg S; Frerker C; Kurz T; Kaur J; Toelg R; Sachse S; Jochheim D; Schäfer U; El-Mawardy M; Robinson DR; Richardt G;
    JACC Cardiovasc Interv; 2020 May; 13(9):1071-1082. PubMed ID: 32305398
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial.
    Lanz J; Kim WK; Walther T; Burgdorf C; Möllmann H; Linke A; Redwood S; Thilo C; Hilker M; Joner M; Thiele H; Conzelmann L; Conradi L; Kerber S; Schymik G; Prendergast B; Husser O; Stortecky S; Heg D; Jüni P; Windecker S; Pilgrim T;
    Lancet; 2019 Nov; 394(10209):1619-1628. PubMed ID: 31570258
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transcatheter Valve SELECTion in Patients With Right Bundle Branch Block and Impact on Pacemaker Implantations.
    Husser O; Pellegrini C; Kim WK; Holzamer A; Pilgrim T; Toggweiler S; Schäfer U; Blumenstein J; Deuschl F; Rheude T; Joner M; Hilker M; Hengstenberg C; Möllmann H
    JACC Cardiovasc Interv; 2019 Sep; 12(18):1781-1793. PubMed ID: 31537278
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Outcome With the Repositionable and Retrievable Boston Scientific Lotus Valve Compared With the Balloon-Expandable Edwards Sapien 3 Valve in Patients Undergoing Transfemoral Aortic Valve Replacement.
    Seeger J; Gonska B; Rottbauer W; Wöhrle J
    Circ Cardiovasc Interv; 2017 Jun; 10(6):. PubMed ID: 28566290
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transfemoral aortic valve implantation with new-generation devices: the repositionable Lotus vs. the balloon-expandable Edwards Sapien 3 valve.
    Nai Fovino L; Badawy MRA; Fraccaro C; D'Onofrio A; Purita PAM; Frigo AC; Tellaroli P; Mauro A; Tusa M; Napodano M; Gerosa G; Iliceto S; Bedogni F; AbdelRheim AER; Tarantini G
    J Cardiovasc Med (Hagerstown); 2018 Nov; 19(11):655-663. PubMed ID: 30299408
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The ACURATE neo Transcatheter Heart Valve: A Comprehensive Analysis of Predictors of Procedural Outcome.
    Kim WK; Möllmann H; Liebetrau C; Renker M; Rolf A; Simon P; Van Linden A; Arsalan M; Doss M; Hamm CW; Walther T
    JACC Cardiovasc Interv; 2018 Sep; 11(17):1721-1729. PubMed ID: 29803694
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Real-World Outcomes for the Fifth-Generation Balloon Expandable Transcatheter Heart Valve in the United States.
    Stinis CT; Abbas AE; Teirstein P; Makkar RR; Chung CJ; Iyer V; Généreux P; Kipperman RM; Harrison JK; Hughes GC; Lyons JM; Rahman A; Kakouros N; Walker J; Roberts DK; Huang PH; Kar B; Dhoble A; Logsdon DP; Khanna PK; Aragon J; McCabe JM
    JACC Cardiovasc Interv; 2024 Apr; 17(8):1032-1044. PubMed ID: 38456883
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Short-Term Outcome and Hemodynamic Performance of Next-Generation Self-Expanding Versus Balloon-Expandable Transcatheter Aortic Valves in Patients With Small Aortic Annulus: A Multicenter Propensity-Matched Comparison.
    Mauri V; Kim WK; Abumayyaleh M; Walther T; Moellmann H; Schaefer U; Conradi L; Hengstenberg C; Hilker M; Wahlers T; Baldus S; Rudolph V; Madershahian N; Rudolph TK
    Circ Cardiovasc Interv; 2017 Oct; 10(10):. PubMed ID: 28951395
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Safety of Next-Day Discharge After Transfemoral Transcatheter Aortic Valve Replacement With a Self-Expandable Versus Balloon-Expandable Valve Prosthesis.
    Moriyama N; Vento A; Laine M
    Circ Cardiovasc Interv; 2019 Jun; 12(6):e007756. PubMed ID: 31167602
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Outcomes of three different new generation transcatheter aortic valve prostheses.
    Costa G; Buccheri S; Barbanti M; Picci A; Todaro D; Di Simone E; La Spina K; D'Arrigo P; Criscione E; Nastasi M; Sgroi C; Tamburino C
    Catheter Cardiovasc Interv; 2020 Feb; 95(3):398-407. PubMed ID: 31609073
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prospective comparison between three TAVR devices: ACURATE neo vs. CoreValve vs. SAPIEN XT. A single heart team experience in patients with severe aortic stenosis.
    Jatene T; Castro-Filho A; Meneguz-Moreno RA; Siqueira DA; Abizaid AAC; Ramos AIO; Arrais M; Le Bihan DCS; Barretto RBM; Moreira AC; Sousa AGMR; Eduardo Sousa J
    Catheter Cardiovasc Interv; 2017 Jul; 90(1):139-146. PubMed ID: 28029207
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Outcomes After Transcatheter Aortic Valve Replacement Using a Novel Balloon-Expandable Transcatheter Heart Valve: A Single-Center Experience.
    Husser O; Pellegrini C; Kessler T; Burgdorf C; Thaller H; Mayr NP; Ott I; Kasel AM; Schunkert H; Kastrati A; Hengstenberg C
    JACC Cardiovasc Interv; 2015 Dec; 8(14):1809-16. PubMed ID: 26718512
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The SAVI-TF Registry: 1-Year Outcomes of the European Post-Market Registry Using the ACURATE neo Transcatheter Heart Valve Under Real-World Conditions in 1,000 Patients.
    Kim WK; Hengstenberg C; Hilker M; Kerber S; Schäfer U; Rudolph T; Linke A; Franz N; Kuntze T; Nef H; Kappert U; Zembala MO; Toggweiler S; Walther T; Möllmann H
    JACC Cardiovasc Interv; 2018 Jul; 11(14):1368-1374. PubMed ID: 30025731
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transfemoral aortic valve implantation is more successful with the Edwards Sapien 3 compared with the Edwards XT for the treatment of symptomatic severe aortic stenosis.
    Gonska B; Seeger J; Junker A; Rodewald C; Trepte U; Scharnbeck D; Rottbauer W; Wöhrle J
    Arch Cardiovasc Dis; 2018; 111(8-9):470-479. PubMed ID: 29128473
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improving outcomes: case-matched comparison of novel second-generation versus first-generation self-expandable transcatheter heart valves.
    Schaefer A; Treede H; Schoen G; Deuschl F; Schofer N; Schneeberger Y; Blankenberg S; Reichenspurner H; Schaefer U; Conradi L
    Eur J Cardiothorac Surg; 2016 Aug; 50(2):368-73. PubMed ID: 26888463
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transcatheter Replacement of Failed Bioprosthetic Valves: Large Multicenter Assessment of the Effect of Implantation Depth on Hemodynamics After Aortic Valve-in-Valve.
    Simonato M; Webb J; Kornowski R; Vahanian A; Frerker C; Nissen H; Bleiziffer S; Duncan A; Rodés-Cabau J; Attizzani GF; Horlick E; Latib A; Bekeredjian R; Barbanti M; Lefevre T; Cerillo A; Hernández JM; Bruschi G; Spargias K; Iadanza A; Brecker S; Palma JH; Finkelstein A; Abdel-Wahab M; Lemos P; Petronio AS; Champagnac D; Sinning JM; Salizzoni S; Napodano M; Fiorina C; Marzocchi A; Leon M; Dvir D
    Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27301396
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 32.