These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 29057776)

  • 21. Randomized Controlled Trial of Radiation Protection With a Patient Lead Shield and a Novel, Nonlead Surgical Cap for Operators Performing Coronary Angiography or Intervention.
    Alazzoni A; Gordon CL; Syed J; Natarajan MK; Rokoss M; Schwalm JD; Mehta SR; Sheth T; Valettas N; Velianou J; Pandie S; Al Khdair D; Tsang M; Meeks B; Colbran K; Waller E; Fu Lee S; Marsden T; Jolly SS
    Circ Cardiovasc Interv; 2015 Aug; 8(8):e002384. PubMed ID: 26253734
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Identification of less-irradiating tube angulations in invasive cardiology.
    Kuon E; Dahm JB; Empen K; Robinson DM; Reuter G; Wucherer M
    J Am Coll Cardiol; 2004 Oct; 44(7):1420-8. PubMed ID: 15464322
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Efficacy of RADPAD® protection drape in reducing radiation exposure to the primary operator during Transcatheter Aortic Valve Implantation (TAVI).
    Sharma D; Ramsewak A; Manoharan G; Spence MS
    Minerva Cardioangiol; 2016 Feb; 64(1):41-6. PubMed ID: 25900558
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Surgeon radiation dose during complex endovascular procedures.
    Kirkwood ML; Guild JB; Arbique GM; Anderson JA; Valentine RJ; Timaran C
    J Vasc Surg; 2015 Aug; 62(2):457-63. PubMed ID: 25937608
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Clinical Evaluation of Protective Garments with Respect to Garment Characteristics and Manufacturer Label Information.
    Lichliter A; Weir V; Heithaus RE; Gipson S; Syed A; West J; Rees C
    J Vasc Interv Radiol; 2017 Jan; 28(1):148-155. PubMed ID: 27789076
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Radiation Exposure of Operators Performing Transesophageal Echocardiography During Percutaneous Structural Cardiac Interventions.
    Crowhurst JA; Scalia GM; Whitby M; Murdoch D; Robinson BJ; Turner A; Johnston L; Margale S; Natani S; Clarke A; Burstow DJ; Raffel OC; Walters DL
    J Am Coll Cardiol; 2018 Mar; 71(11):1246-1254. PubMed ID: 29544609
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Last series hold: a feature on fluoroscopy systems with the potential to reduce patient and operator dose.
    Radvany MG; Mahesh M
    J Am Coll Radiol; 2015 Aug; 12(8):860-1. PubMed ID: 26250978
    [No Abstract]   [Full Text] [Related]  

  • 28. Balloon pulmonary angioplasty: applicability of C-Arm CT for procedure guidance.
    Hinrichs JB; Renne J; Hoeper MM; Olsson KM; Wacker FK; Meyer BC
    Eur Radiol; 2016 Nov; 26(11):4064-4071. PubMed ID: 26905868
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Changing the strategy of balloon pulmonary angioplasty resulted in a reduced complication rate in patients with chronic thromboembolic pulmonary hypertension. A single-centre European experience.
    Kurzyna M; Darocha S; Pietura R; Pietrasik A; Norwa J; Mańczak R; Wieteska M; Biederman A; Matsubara H; Torbicki A
    Kardiol Pol; 2017; 75(7):645-654. PubMed ID: 28553870
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Three-dimensional fractal analysis of 99mTc-MAA SPECT images in chronic thromboembolic pulmonary hypertension for evaluation of response to balloon pulmonary angioplasty: association with pulmonary arterial pressure.
    Maruoka Y; Nagao M; Baba S; Isoda T; Kitamura Y; Yamazaki Y; Abe K; Sasaki M; Abe K; Honda H
    Nucl Med Commun; 2017 Jun; 38(6):480-486. PubMed ID: 28430738
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A Review of Radiation Protection Solutions for the Staff in the Cardiac Catheterisation Laboratory.
    Badawy MK; Deb P; Chan R; Farouque O
    Heart Lung Circ; 2016 Oct; 25(10):961-7. PubMed ID: 27139116
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Types and arrangement of thyroid shields to reduce exposure of surgeons to ionizing radiation during intraoperative use of C-arm fluoroscopy.
    Lee SY; Min E; Bae J; Chung CY; Lee KM; Kwon SS; Park MS; Lee K
    Spine (Phila Pa 1976); 2013 Nov; 38(24):2108-12. PubMed ID: 23963017
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Reduction of operator radiation dose by a pelvic lead shield during cardiac catheterization by radial access: comparison with femoral access.
    Lange HW; von Boetticher H
    JACC Cardiovasc Interv; 2012 Apr; 5(4):445-9. PubMed ID: 22516403
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Balloon pulmonary angioplasty: an additional treatment option to improve the prognosis of patients with chronic thromboembolic pulmonary hypertension.
    Taniguchi Y; Miyagawa K; Nakayama K; Kinutani H; Shinke T; Okada K; Okita Y; Hirata KI; Emoto N
    EuroIntervention; 2014 Aug; 10(4):518-25. PubMed ID: 25138190
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Balloon pulmonary angioplasty: An additional treatment option to improve the status of patients with chronic thromboembolic pulmonary hypertension].
    Bouvaist H
    Rev Pneumol Clin; 2017 Feb; 73(1):50-54. PubMed ID: 28162796
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effectiveness of additional lead shielding to protect staff from scattering radiation during endoscopic retrograde cholangiopancreatography procedures.
    Morishima Y; Chida K; Meguro T
    J Radiat Res; 2018 Mar; 59(2):225-232. PubMed ID: 29409055
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Balloon pulmonary angioplasty improves interventricular dyssynchrony in patients with inoperable chronic thromboembolic pulmonary hypertension: a cardiac MR imaging study.
    Yamasaki Y; Nagao M; Abe K; Hosokawa K; Kawanami S; Kamitani T; Yamanouchi T; Horimoto K; Yabuuchi H; Honda H
    Int J Cardiovasc Imaging; 2017 Feb; 33(2):229-239. PubMed ID: 27672065
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Reduction of occupational radiation dose in staff at the cardiac catheterisation laboratory by protective material placed on the patient.
    Ordiales JM; Nogales JM; Sánchez-Casanueva R; Vano E; Fernández JM; Álvarez FJ; Ramos J; Martínez G; López-Mínguez JR
    Radiat Prot Dosimetry; 2015 Jul; 165(1-4):272-5. PubMed ID: 25848096
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Assessment of occupational dose reduction with the use of a floor mounted mobile lead radiation protection shield.
    Scott H; Gallagher S; Abbott W; Talboys M
    J Radiol Prot; 2022 Aug; 42(3):. PubMed ID: 35850100
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Effective Techniques to Reduce Radiation Exposure to Medical Staff during Assist of X-ray Computed Tomography Examination].
    Miyajima R; Fujibuchi T; Miyachi Y; Tateishi S; Uno Y; Amakawa K; Ohura H; Orita S
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2018; 74(4):326-334. PubMed ID: 29681599
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.