These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
196 related articles for article (PubMed ID: 29058110)
1. Computational prediction of the effects of the intra-aortic balloon pump on heart failure with valvular regurgitation using a 3D cardiac electromechanical model. Kim CH; Song KS; Trayanova NA; Lim KM Med Biol Eng Comput; 2018 May; 56(5):853-863. PubMed ID: 29058110 [TBL] [Abstract][Full Text] [Related]
2. Computational analysis of the effect of mitral and aortic regurgitation on the function of ventricular assist devices using 3D cardiac electromechanical model. Kim YS; Yuniarti AR; Song KS; Trayanova NA; Shim EB; Lim KM Med Biol Eng Comput; 2018 May; 56(5):889-898. PubMed ID: 29080191 [TBL] [Abstract][Full Text] [Related]
3. Computational quantification of the cardiac energy consumption during intra-aortic balloon pumping using a cardiac electromechanics model. Lim KM; Lee JS; Gyeong MS; Choi JS; Choi SW; Shim EB J Korean Med Sci; 2013 Jan; 28(1):93-9. PubMed ID: 23341718 [TBL] [Abstract][Full Text] [Related]
4. Computational Analysis of Pumping Efficacy of a Left Ventricular Assist Device according to Cannulation Site in Heart Failure with Valvular Regurgitation. Heikhmakhtiar AK; Lim KM Comput Math Methods Med; 2016; 2016():6930482. PubMed ID: 28115981 [TBL] [Abstract][Full Text] [Related]
5. Intra-aortic balloon pumping in acute mitral regurgitation reduces aortic impedance and regurgitant fraction. Dekker AL; Reesink KD; van der Veen FH; van Ommen GV; Geskes GG; Soemers AC; Maessen JG Shock; 2003 Apr; 19(4):334-8. PubMed ID: 12688544 [TBL] [Abstract][Full Text] [Related]
6. Miniature intracardiac assist device provides more effective cardiac unloading and circulatory support during severe left heart failure than intraaortic balloon pumping. Reesink KD; Dekker AL; Van Ommen V; Soemers C; Geskes GG; van der Veen FH; Maessen JG Chest; 2004 Sep; 126(3):896-902. PubMed ID: 15364772 [TBL] [Abstract][Full Text] [Related]
7. Computational analysis of the effect of valvular regurgitation on ventricular mechanics using a 3D electromechanics model. Lim KM; Hong SB; Lee BK; Shim EB; Trayanova N J Physiol Sci; 2015 Mar; 65(2):159-64. PubMed ID: 25644379 [TBL] [Abstract][Full Text] [Related]
8. Acute haemodynamic effects of intra-aortic balloon pump and cardiac resynchronization therapy. Bonanno C; Ometto R; La Vecchia L; Fontanelli A J Cardiovasc Med (Hagerstown); 2008 Jul; 9(7):719-24. PubMed ID: 18545074 [TBL] [Abstract][Full Text] [Related]
9. Modeling the interaction between the intra-aortic balloon pump and the cardiovascular system: the effect of timing. Schampaert S; Rutten MC; van T Veer M; van Nunen LX; Tonino PA; Pijls NH; van de Vosse FN ASAIO J; 2013; 59(1):30-6. PubMed ID: 23263334 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of cardiac beat synchronization control for a rotary blood pump on valvular regurgitation with a mathematical model. Ogawa D; Kobayashi S; Yamazaki K; Motomura T; Nishimura T; Shimamura J; Tsukiya T; Mizuno T; Takewa Y; Tatsumi E; Nishinaka T Artif Organs; 2021 Feb; 45(2):124-134. PubMed ID: 32813920 [TBL] [Abstract][Full Text] [Related]
11. Myocardial mechanics in aortic and mitral valvular regurgitation: the concept of instantaneous impedance as a determinant of the performance of the intact heart. Urschel CW; Covell JW; Sonnenblick EH; Ross J; Braunwald E J Clin Invest; 1968 Apr; 47(4):867-83. PubMed ID: 5641623 [TBL] [Abstract][Full Text] [Related]
13. Effects of intra-aortic balloon pump counterpulsation on left ventricular mechanoenergetics in a porcine model of acute ischemic heart failure. Malliaras K; Charitos E; Diakos N; Pozios I; Papalois A; Terrovitis J; Nanas J J Cardiovasc Transl Res; 2014 Dec; 7(9):810-20. PubMed ID: 25376149 [TBL] [Abstract][Full Text] [Related]
14. [Effect of volume load of the left ventricle in aortic and mitral insufficiency on the geometry and function of the right ventricle]. Unterberg R; Römmich P; Völker W; Mauser M; Karsch KR Z Kardiol; 1987 Dec; 76(12):761-9. PubMed ID: 3439251 [TBL] [Abstract][Full Text] [Related]
15. Effects of intra-aortic balloon pump timing on baroreflex activities in a closed-loop cardiovascular hybrid model. Fresiello L; Khir AW; Di Molfetta A; Kozarski M; Ferrari G Artif Organs; 2013 Mar; 37(3):237-47. PubMed ID: 23121229 [TBL] [Abstract][Full Text] [Related]
16. Associations of aortic and mitral regurgitation with body composition and myocardial energy expenditure in adults with hypertension: the Hypertension Genetic Epidemiology Network study. Palmieri V; Bella JN; Arnett DK; Oberman A; Kitzman DW; Hopkins PN; Rao DC; Roman MJ; Devereux RB; Am Heart J; 2003 Jun; 145(6):1071-7. PubMed ID: 12796765 [TBL] [Abstract][Full Text] [Related]
17. Utility of intra-aortic balloon pump support for ventricular septal rupture and acute mitral regurgitation complicating acute myocardial infarction. Kettner J; Sramko M; Holek M; Pirk J; Kautzner J Am J Cardiol; 2013 Dec; 112(11):1709-13. PubMed ID: 24035169 [TBL] [Abstract][Full Text] [Related]