These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 29060220)

  • 1. Effect of temperature variation on remote pressure readout in wirelessly powered intracranial pressure monitoring system.
    Khan MWA; Rizwan M; Sydanheimo L; Rahmat-Samii Y; Ukkonen L; Bjorninen T
    Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():1728-1731. PubMed ID: 29060220
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implantable Wireless Intracranial Pressure Monitoring Based on Air Pressure Sensing.
    Jiang H; Guo Y; Wu Z; Zhang C; Jia W; Wang Z
    IEEE Trans Biomed Circuits Syst; 2018 Oct; 12(5):1076-1087. PubMed ID: 30010593
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Designing and Implementing an Implantable Wireless Micromanometer System for Real-Time Bladder Pressure Monitoring: A Preliminary Study.
    Li YT; Yang LY; Hsu WT; Peng CW
    Sensors (Basel); 2020 Aug; 20(16):. PubMed ID: 32824415
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Intracranial Pressure Monitor Based on Wireless].
    Han H; Zhang Y; Qian C; Wang H; Qian Z; Li W
    Zhongguo Yi Liao Qi Xie Za Zhi; 2017 Mar; 41(2):89-91. PubMed ID: 29862675
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Novel Intracranial Pressure Readout Circuit for Passive Wireless LC Sensor.
    Wang F; Zhang X; Shokoueinejad M; Iskandar BJ; Medow JE; Webster JG
    IEEE Trans Biomed Circuits Syst; 2017 Oct; 11(5):1123-1132. PubMed ID: 28809712
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An Implantable RFID Sensor Tag toward Continuous Glucose Monitoring.
    Xiao Z; Tan X; Chen X; Chen S; Zhang Z; Zhang H; Wang J; Huang Y; Zhang P; Zheng L; Min H
    IEEE J Biomed Health Inform; 2015 May; 19(3):910-9. PubMed ID: 25823049
    [TBL] [Abstract][Full Text] [Related]  

  • 7. On the feasibility of a liquid crystal polymer pressure sensor for intracranial pressure measurement.
    Sattayasoonthorn P; Suthakorn J; Chamnanvej S
    Biomed Tech (Berl); 2019 Sep; 64(5):543-553. PubMed ID: 30875314
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In-Vitro Demonstration of Ultra-Reliable, Wireless and Batteryless Implanted Intracranial Sensors Operated on Loci of Exceptional Points.
    Yang M; Ye Z; Alsaab N; Farhat M; Chen PY
    IEEE Trans Biomed Circuits Syst; 2022 Apr; 16(2):287-295. PubMed ID: 35380967
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Wirelessly Powered Signal Regeneration to Improve the Remote Detectability of an Inductive Pressure Sensor.
    Qian W; Qian C
    IEEE Trans Biomed Circuits Syst; 2019 Oct; 13(5):1011-1020. PubMed ID: 31352353
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Basic characteristics of implantable flexible pressure sensor for wireless readout using MRI.
    Nakamura T; Inoue Y; Kim D; Matsuhisa N; Yokota T; Sekitani T; Someya T; Sekino M
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():2338-41. PubMed ID: 25570457
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Injectable ultrasonic sensor for wireless monitoring of intracranial signals.
    Tang H; Yang Y; Liu Z; Li W; Zhang Y; Huang Y; Kang T; Yu Y; Li N; Tian Y; Liu X; Cheng Y; Yin Z; Jiang X; Chen X; Zang J
    Nature; 2024 Jun; 630(8015):84-90. PubMed ID: 38840015
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A surface acoustic wave ICP sensor with good temperature stability.
    Zhang B; Hu H; Ye A; Zhang P
    Technol Health Care; 2017 Jul; 25(S1):435-441. PubMed ID: 28582931
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Subcubic Millimeter Wireless Implantable Intraocular Pressure Monitor Microsystem.
    Bhamra H; Tsai JW; Huang YW; Yuan Q; Shah JV; Irazoqui P
    IEEE Trans Biomed Circuits Syst; 2017 Dec; 11(6):1204-1215. PubMed ID: 29293418
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Wireless energizing system for an automated implantable sensor.
    Swain B; Nayak PP; Kar DP; Bhuyan S; Mishra LP
    Rev Sci Instrum; 2016 Jul; 87(7):074708. PubMed ID: 27475582
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A novel fully implantable wireless sensor system for monitoring hypertension patients.
    Cleven NJ; Müntjes JA; Fassbender H; Urban U; Görtz M; Vogt H; Gräfe M; Göttsche T; Penzkofer T; Schmitz-Rode T; Mokwa W
    IEEE Trans Biomed Eng; 2012 Nov; 59(11):3124-30. PubMed ID: 22955864
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An Implantable Wireless System for Remote Hemodynamic Monitoring of Heart Failure Patients.
    Besirli M; Ture K; Beghetti M; Maloberti F; Dehollain C; Mattavelli M; Barrettino D
    IEEE Trans Biomed Circuits Syst; 2023 Aug; 17(4):688-700. PubMed ID: 37155376
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Interventional placement of thin coil shaped implants powered wirelessly for monitoring vital signals and controlling abnormal activities by electro-stimulation.
    Ohta H; Honda M; Takamiya M
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():3035-3038. PubMed ID: 28268951
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An NFC-Enabled CMOS IC for a Wireless Fully Implantable Glucose Sensor.
    DeHennis A; Getzlaff S; Grice D; Mailand M
    IEEE J Biomed Health Inform; 2016 Jan; 20(1):18-28. PubMed ID: 26372659
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Vascular capsule for telemetric monitoring of blood pressure.
    Schmitz-Rode T; Schnakenberg U; Pfeffer JG; Piroth W; Vom Bögel G; Mokwa W; Günther RW
    Rofo; 2003 Feb; 175(2):282-6. PubMed ID: 12584632
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A telemetric pressure sensor system for biomedical applications.
    Ginggen A; Tardy Y; Crivelli R; Bork T; Renaud P
    IEEE Trans Biomed Eng; 2008 Apr; 55(4):1374-81. PubMed ID: 18390328
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.