These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
253 related articles for article (PubMed ID: 29065654)
1. Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis. Zhou JJ; Zhao M; Liu D; Liu HY; Du CF J Healthc Eng; 2017; 2017():8590251. PubMed ID: 29065654 [TBL] [Abstract][Full Text] [Related]
2. Semi-rigid screws provide an auxiliary option to plate working length to control interfragmentary movement in locking plate fixation at the distal femur. Heyland M; Duda GN; Haas NP; Trepczynski A; Döbele S; Höntzsch D; Schaser KD; Märdian S Injury; 2015 Oct; 46 Suppl 4():S24-32. PubMed ID: 26542863 [TBL] [Abstract][Full Text] [Related]
3. Biomechanical Comparison of Locking Plate and Cancellous Screw Techniques in Medial Malleolar Fractures: A Finite Element Analysis. Jiang D; Zhan S; Wang Q; Ling M; Hu H; Jia W J Foot Ankle Surg; 2019 Nov; 58(6):1138-1144. PubMed ID: 31562067 [TBL] [Abstract][Full Text] [Related]
4. Finite element analysis of different locking plate fixation methods for the treatment of ulnar head fracture. Zhang Y; Shao Q; Yang C; Ai C; Zhou D; Yu Y; Sun G J Orthop Surg Res; 2021 Mar; 16(1):191. PubMed ID: 33722253 [TBL] [Abstract][Full Text] [Related]
5. Finite element analysis comparison between superior clavicle locking plate with and without screw holes above fracture zone in midshaft clavicular fracture. Pengrung N; Lakdee N; Puncreobutr C; Lohwongwatana B; Sa-Ngasoongsong P BMC Musculoskelet Disord; 2019 Oct; 20(1):465. PubMed ID: 31640668 [TBL] [Abstract][Full Text] [Related]
6. [Internal fixation of radial shaft fractures: Anatomical and biomechanical principles]. Bartoníček J; Naňka O; Tuček M Rozhl Chir; 2015 Oct; 94(10):425-36. PubMed ID: 26556020 [TBL] [Abstract][Full Text] [Related]
7. [Finite element analysis of the stability of Mason type Ⅲ radial head fracture fixed with three cross-bridge headless compression screw and locking plate]. Yin H; Li Y; Zhao G; Xie J; Ning RD; Zhou EC Zhongguo Gu Shang; 2024 Jan; 37(1):57-60. PubMed ID: 38286452 [TBL] [Abstract][Full Text] [Related]
8. Biomechanical effect of the configuration of screw hole style on locking plate fixation in proximal humerus fracture with a simulated gap: A finite element analysis. Zhang YK; Wei HW; Lin KP; Chen WC; Tsai CL; Lin KJ Injury; 2016 Jun; 47(6):1191-5. PubMed ID: 26975793 [TBL] [Abstract][Full Text] [Related]
9. The comparison of stress and strain between custom-designed bone plates (CDBP) and locking compression plate (LCP) for distal femur fracture. Shams SF; Mehdizadeh A; Movahedi MM; Paydar S; Haghpanah SA Eur J Orthop Surg Traumatol; 2023 Jan; 33(1):191-197. PubMed ID: 35001211 [TBL] [Abstract][Full Text] [Related]
10. Biomechanical analysis and clinical effects of bridge combined fixation system for femoral fractures. Wang DX; Xiong Y; Deng H; Jia F; Gu S; Liu BL; Li QH; Pu Q; Zhang ZZ Proc Inst Mech Eng H; 2014 Sep; 228(9):899-907. PubMed ID: 25201264 [TBL] [Abstract][Full Text] [Related]
11. [Investigation on biomechanics behavior using three-dimensional finite element analysis for femur shaft fracture treated with locking compression plate]. He Q; Jiang W; Luo J Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2014 Aug; 31(4):777-81, 792. PubMed ID: 25464786 [TBL] [Abstract][Full Text] [Related]
12. Finite element analysis comparison of Type 42A2 fracture fixed with external titanium alloy locking plate and traditional external fixation frame. Fang S; Zhang L; Yang Y; Wang Y; Guo J; Mi L J Orthop Surg Res; 2023 Oct; 18(1):815. PubMed ID: 37907959 [TBL] [Abstract][Full Text] [Related]
13. Biomechanical effect of medial cortical support and medial screw support on locking plate fixation in proximal humeral fractures with a medial gap: a finite element analysis. Yang P; Zhang Y; Liu J; Xiao J; Ma LM; Zhu CR Acta Orthop Traumatol Turc; 2015; 49(2):203-9. PubMed ID: 26012943 [TBL] [Abstract][Full Text] [Related]
14. Influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study. Sakai R; Uchino M; Yoneo T; Ohtaki Y; Minehara H; Matsuura T; Gomi T; Ujihira M J Orthop Surg Res; 2017 Feb; 12(1):34. PubMed ID: 28228100 [TBL] [Abstract][Full Text] [Related]
15. Dual small fragment plating improves screw-to-screw load sharing for mid-diaphyseal humeral fracture fixation: a finite element study. Kosmopoulos V; Luedke C; Nana AD Technol Health Care; 2015; 23(1):83-92. PubMed ID: 25408282 [TBL] [Abstract][Full Text] [Related]
16. Working length of locking plates determines interfragmentary movement in distal femur fractures under physiological loading. Märdian S; Schaser KD; Duda GN; Heyland M Clin Biomech (Bristol, Avon); 2015 May; 30(4):391-6. PubMed ID: 25716162 [TBL] [Abstract][Full Text] [Related]
17. [A new exploration and consideration of Type A fracture of distal femur based on finite element biomechanical analysis]. Xu D; Sun RJ; Wang TY; Zhao XQ; Bi ZG; Geng S Zhonghua Wai Ke Za Zhi; 2019 Nov; 57(11):812-817. PubMed ID: 31694128 [No Abstract] [Full Text] [Related]
18. Ability of modern distal tibia plates to stabilize comminuted pilon fracture fragments: Is dual plate fixation necessary? Penny P; Swords M; Heisler J; Cien A; Sands A; Cole P Injury; 2016 Aug; 47(8):1761-9. PubMed ID: 27264277 [TBL] [Abstract][Full Text] [Related]
19. Comparison of a multidimensional cross locking plate versus a locking compression plate for the treatment of femoral shaft nonunion: Finite element analysis. Zhang W; Hao M; Chang Z; Wu Y; Tang P; Chen H Med Eng Phys; 2020 Sep; 83():106-111. PubMed ID: 32507679 [TBL] [Abstract][Full Text] [Related]
20. Plating System Design Determines Mechanical Environment in Long Bone Mid-shaft Fractures: A Finite Element Analysis. Wang J; Zhang X; Li S; Yin B; Liu G; Cheng X; Zhang Y J Invest Surg; 2020 Sep; 33(8):699-708. PubMed ID: 30885085 [No Abstract] [Full Text] [Related] [Next] [New Search]