These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

231 related articles for article (PubMed ID: 29065654)

  • 41. Finite Element- and Design of Experiment-Derived Optimization of Screw Configurations and a Locking Plate for Internal Fixation System.
    Sheng W; Ji A; Fang R; He G; Chen C
    Comput Math Methods Med; 2019; 2019():5636528. PubMed ID: 31531124
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Modeling attachment and compressive loading of locking and non-locking plate fixation: a finite element investigation of a supracondylar femur fracture model.
    Samiezadeh A; McLachlin S; Ng M; Samiezadeh S; Larouche J; Whyne C
    Comput Methods Biomech Biomed Engin; 2022 Nov; 25(14):1629-1636. PubMed ID: 35098810
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Improving stability of locking compression plates through a design modification: a computational investigation.
    Anitha D; Das De S; Sun KK; Doshi HK; Lee T
    Comput Methods Biomech Biomed Engin; 2015; 18(2):153-61. PubMed ID: 23582021
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Biomechanical testing of the locking compression plate: when does the distance between bone and implant significantly reduce construct stability?
    Ahmad M; Nanda R; Bajwa AS; Candal-Couto J; Green S; Hui AC
    Injury; 2007 Mar; 38(3):358-64. PubMed ID: 17296199
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Assessment of the Biomechanical Performance of 5 Plating Techniques in Fixation of Mandibular Subcondylar Fracture Using Finite Element Analysis.
    Darwich MA; Albogha MH; Abdelmajeed A; Darwich K
    J Oral Maxillofac Surg; 2016 Apr; 74(4):794.e1-8. PubMed ID: 26706490
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Periprosthetic femoral fracture fixation: a biomechanical comparison between proximal locking screws and cables.
    Graham SM; Mak JH; Moazen M; Leonidou A; Jones AC; Wilcox RK; Tsiridis E
    J Orthop Sci; 2015 Sep; 20(5):875-80. PubMed ID: 25968896
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Biomechanical evaluation on a novel design of biodegradable embossed locking compression plate for orthopaedic applications using finite element analysis.
    Chandra G; Pandey A
    Biomech Model Mechanobiol; 2022 Oct; 21(5):1371-1392. PubMed ID: 35717547
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.
    Kandemir U; Augat P; Konowalczyk S; Wipf F; von Oldenburg G; Schmidt U
    J Orthop Trauma; 2017 Aug; 31(8):e241-e246. PubMed ID: 28394844
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Biomechanical Comparison of Bicortical, Unicortical, and Unicortical Far-Cortex-Abutting Screw Fixations in Plated Comminuted Midshaft Clavicle Fractures.
    Croley JS; Morris RP; Amin A; Lindsey RW; Gugala Z
    J Hand Surg Am; 2016 Jun; 41(6):703-11. PubMed ID: 27113909
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Application of computer-aided design and 3D-printed navigation template in Locking Compression Pediatric Hip Plate
    Zheng P; Yao Q; Xu P; Wang L
    Int J Comput Assist Radiol Surg; 2017 May; 12(5):865-871. PubMed ID: 28190127
    [TBL] [Abstract][Full Text] [Related]  

  • 51. The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: cables, screws, or both?
    Shah S; Kim SY; Dubov A; Schemitsch EH; Bougherara H; Zdero R
    Proc Inst Mech Eng H; 2011 Sep; 225(9):845-56. PubMed ID: 22070022
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Fixation of a split fracture of the lateral tibial plateau with a locking screw plate instead of cannulated screws would allow early weight bearing: a computational exploration.
    Carrera I; Gelber PE; Chary G; González-Ballester MA; Monllau JC; Noailly J
    Int Orthop; 2016 Oct; 40(10):2163-2169. PubMed ID: 26780714
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Plate configuration for biological reconstructions of femoral intercalary defect - a finite element evaluation.
    He Z; Huang S; Ji T; Tang X; Yang R; Guo W
    Comput Methods Programs Biomed; 2022 Sep; 224():107006. PubMed ID: 35816816
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Locking plates and their effects on healing conditions and stress distribution: A femoral neck fracture study in cadavers.
    Basso T; Klaksvik J; Foss OA
    Clin Biomech (Bristol, Avon); 2014 May; 29(5):595-8. PubMed ID: 24726777
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Effect of Calcar Screw in Locking Compression Plate System for Osteoporotic Proximal Humerus Fracture: A Finite Element Analysis Study.
    Lee JS; Kim JH; Kim KG; Yoon YC
    Biomed Res Int; 2022; 2022():1268774. PubMed ID: 36158892
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Proximal Screw Configuration Alters Peak Plate Strain Without Changing Construct Stiffness in Comminuted Supracondylar Femur Fractures.
    McLachlin S; Kreder H; Ng M; Jenkinson R; Whyne C; Larouche J
    J Orthop Trauma; 2017 Dec; 31(12):e418-e424. PubMed ID: 28902085
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Biomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support.
    He Y; Zhang Y; Wang Y; Zhou D; Wang F
    J Orthop Surg Res; 2017 May; 12(1):72. PubMed ID: 28499398
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Internal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate fracture stability.
    Willis AA; Kutsumi K; Zobitz ME; Cooney WP
    J Bone Joint Surg Am; 2006 Nov; 88(11):2411-7. PubMed ID: 17079398
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Utility of cement injection to stabilize split-depression tibial plateau fracture by minimally invasive methods: A finite element analysis.
    Belaid D; Vendeuvre T; Bouchoucha A; Brémand F; Brèque C; Rigoard P; Germaneau A
    Clin Biomech (Bristol, Avon); 2018 Jul; 56():27-35. PubMed ID: 29777960
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Numerical simulation research to both the external fixation surgery scheme of intertrochanteric fracture and the healing process, and its clinical application.
    Wang XK; Ye JD; Gu FS; Wang AG; Zhang CQ; Tian QQ; Li X; Dong LM
    Biomed Mater Eng; 2014; 24(1):625-32. PubMed ID: 24211947
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.