BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

92 related articles for article (PubMed ID: 29066214)

  • 1. Extended utilization of a
    Yamada T; Ishizu H; Arai K; Shiina T
    Appl Radiat Isot; 2018 Apr; 134():89-94. PubMed ID: 29066214
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development of a traceable calibration methodology for solid (68)Ge/(68)Ga sources used as a calibration surrogate for (18)F in radionuclide activity calibrators.
    Zimmerman BE; Cessna JT
    J Nucl Med; 2010 Mar; 51(3):448-53. PubMed ID: 20197450
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Quality control of dose calibrator using a traceable syringe-type (68)Ge/(68)Ga calibration source].
    Miyaji N; Miwa K; Wagatsuma K; Umeda T; Murata T; Takiguchi T; Koizumi M
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2013 Dec; 69(12):1379-86. PubMed ID: 24366558
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Traceable point-like
    Hasegawa T; Okamoto M; Yamada T; Ishizu H; Mikamoto T; Sato Y; Miyatake H; Kikuchi K; Inoue Y
    Radiol Phys Technol; 2020 Jun; 13(2):170-176. PubMed ID: 32361900
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Standardization of
    Kulkarni DB; Joseph L; Anuradha R; Kulkarni MS; Tomar BS
    Appl Radiat Isot; 2017 May; 123():6-10. PubMed ID: 28189091
    [No Abstract]   [Full Text] [Related]  

  • 6. Multicenter study of quantitative PET system harmonization using NIST-traceable
    Miwa K; Wagatsuma K; Iimori T; Sawada K; Kamiya T; Sakurai M; Miyaji N; Murata T; Sato E
    Phys Med; 2018 Aug; 52():98-103. PubMed ID: 30139617
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Correction factors for source strength determination in HDR brachytherapy using the in-phantom method.
    Ubrich F; Wulff J; Engenhart-Cabillic R; Zink K
    Z Med Phys; 2014 May; 24(2):138-52. PubMed ID: 24021956
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of Recent Change in the National Institute of Standards and Technology Standard for 18F on the Relative Response of 68Ge-Based Mock Syringe Dose Calibrator Standards.
    Zimmerman BE; Bergeron DE; Cessna JT
    J Nucl Med; 2015 Sep; 56(9):1453-7. PubMed ID: 26182967
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparative study of Curiementor ionization chambers using Monte Carlo simulations.
    Simões C; Caldeira M; Oliveira C
    Appl Radiat Isot; 2010 Jun; 68(6):1121-7. PubMed ID: 20133143
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Chamber-quality factors in 60Co for three plane-parallel chambers for the dosimetry of electrons, protons and heavier charged particles: PENELOPE Monte Carlo simulations.
    Panettieri V; Sempau J; Andreo P
    Phys Med Biol; 2008 Nov; 53(21):5917-26. PubMed ID: 18836218
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy, reproducibility, and uncertainty analysis of thyroid-probe-based activity measurements for determination of dose calibrator settings.
    Esquinas PL; Tanguay J; Gonzalez M; Vuckovic M; Rodríguez-Rodríguez C; Häfeli UO; Celler A
    Med Phys; 2016 Dec; 43(12):6309. PubMed ID: 27908190
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Calculation of personal dose equivalent for positron-emitting radionuclides using Monte Carlo code EGS5.
    Kato T; Aoki K; Yokoyama S; Ejiri K; Minami K; Yashima H; Taniguchi A; Nakamura T; Hirayama H
    Radiat Prot Dosimetry; 2011 Jul; 146(1-3):202-5. PubMed ID: 21498852
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Calibration coefficient of reference brachytherapy ionization chamber using analytical and Monte Carlo methods.
    Kumar S; Srinivasan P; Sharma SD
    Appl Radiat Isot; 2010 Jun; 68(6):1108-15. PubMed ID: 20079657
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Investigation of a 90Sr/90Y source for intra-ocular treatment of wet age-related macular degeneration.
    Holmes SM; Micka JA; DeWerd LA
    Med Phys; 2009 Oct; 36(10):4370-8. PubMed ID: 19928067
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Two determinations of the Ge-68 half-life.
    Bergeron DE; Cessna JT; Zimmerman BE
    Appl Radiat Isot; 2018 Apr; 134():416-420. PubMed ID: 29100721
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A radiation quality correction factor k for well-type ionization chambers for the measurement of the reference air kerma rate of (60)Co HDR brachytherapy sources.
    Schüller A; Meier M; Selbach HJ; Ankerhold U
    Med Phys; 2015 Jul; 42(7):4285-94. PubMed ID: 26133626
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On the implementation of a recently proposed dosimetric formalism to a robotic radiosurgery system.
    Pantelis E; Moutsatsos A; Zourari K; Kilby W; Antypas C; Papagiannis P; Karaiskos P; Georgiou E; Sakelliou L
    Med Phys; 2010 May; 37(5):2369-79. PubMed ID: 20527571
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of surface dose rate of indigenous (32)P patch brachytherapy source by experimental and Monte Carlo methods.
    Kumar S; Srinivasan P; Sharma SD; Saxena SK; Bakshi AK; Dash A; Babu DA; Sharma DN
    Appl Radiat Isot; 2015 Sep; 103():120-7. PubMed ID: 26086681
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of absorbed dose-to-water for an HDR (192)Ir source with ionization chambers in a sandwich setup.
    Araki F; Kouno T; Ohno T; Kakei K; Yoshiyama F; Kawamura S
    Med Phys; 2013 Sep; 40(9):092101. PubMed ID: 24007170
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Calibration of ionization chamber for ¹⁸F and ⁶⁸Ga.
    da Silva CJ; de Oliveira EM; Iwahara A; Delgado JU; Poledna R; de Oliveira AE; Moreira DS; da Silva RL; Gomes Rdos S; de Veras EV
    Appl Radiat Isot; 2014 May; 87():188-91. PubMed ID: 24361323
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.