These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
223 related articles for article (PubMed ID: 29066280)
1. Implantation and testing of a novel episcleral pressure transducer: A new approach to telemetric intraocular pressure monitoring. Mariacher S; Ebner M; Hurst J; Szurman P; Januschowski K Exp Eye Res; 2018 Jan; 166():84-90. PubMed ID: 29066280 [TBL] [Abstract][Full Text] [Related]
2. Investigation of a novel implantable suprachoroidal pressure transducer for telemetric intraocular pressure monitoring. Mariacher S; Ebner M; Januschowski K; Hurst J; Schnichels S; Szurman P Exp Eye Res; 2016 Oct; 151():54-60. PubMed ID: 27456134 [TBL] [Abstract][Full Text] [Related]
3. Implantation of a novel telemetric intraocular pressure sensor in patients with glaucoma (ARGOS study): 1-year results. Koutsonas A; Walter P; Roessler G; Plange N Invest Ophthalmol Vis Sci; 2015 Jan; 56(2):1063-9. PubMed ID: 25613949 [TBL] [Abstract][Full Text] [Related]
4. Long-term follow-up after implantation of a telemetric intraocular pressure sensor in patients with glaucoma: a safety report. Koutsonas A; Walter P; Roessler G; Plange N Clin Exp Ophthalmol; 2018 Jul; 46(5):473-479. PubMed ID: 29136327 [TBL] [Abstract][Full Text] [Related]
5. Development of a completely encapsulated intraocular pressure sensor. Walter P; Schnakenberg U; vom Bögel G; Ruokonen P; Krüger C; Dinslage S; Lüdtke Handjery HC; Richter H; Mokwa W; Diestelhorst M; Krieglstein GK Ophthalmic Res; 2000; 32(6):278-84. PubMed ID: 11015039 [TBL] [Abstract][Full Text] [Related]
6. Telemetric Intraocular Pressure Monitoring after Boston Keratoprosthesis Surgery Using the Eyemate-IO Sensor: Dynamics in the First Year. Enders P; Hall J; Bornhauser M; Mansouri K; Altay L; Schrader S; Dietlein TS; Bachmann BO; Neuhann T; Cursiefen C Am J Ophthalmol; 2019 Oct; 206():256-263. PubMed ID: 30849343 [TBL] [Abstract][Full Text] [Related]
7. [Self-tonometry with a Telemetric Intraocular Pressure Sensor in Patients With Glaucoma]. Koutsonas A; Walter P; Plange N Klin Monbl Augenheilkd; 2016 Jun; 233(6):743-8. PubMed ID: 26609675 [TBL] [Abstract][Full Text] [Related]
8. Assessing the True Intraocular Pressure in the Non-human Primate. McAllister F; Harwerth R; Patel N Optom Vis Sci; 2018 Feb; 95(2):113-119. PubMed ID: 29370024 [TBL] [Abstract][Full Text] [Related]
9. [Continuous intraocular pressure measurement over several days with the Codman Microsensor--a case report]. Höh H; Schwanengel M Klin Monbl Augenheilkd; 1999 Sep; 215(3):186-96. PubMed ID: 10528285 [TBL] [Abstract][Full Text] [Related]
10. The Icare HOME (TA022) Study: Performance of an Intraocular Pressure Measuring Device for Self-Tonometry by Glaucoma Patients. Mudie LI; LaBarre S; Varadaraj V; Karakus S; Onnela J; Munoz B; Friedman DS Ophthalmology; 2016 Aug; 123(8):1675-1684. PubMed ID: 27289178 [TBL] [Abstract][Full Text] [Related]
11. Automated, Noncontact Intraocular Pressure Home Monitoring after Implantation of a Novel Telemetric Intraocular Pressure Sensor in Patients with Glaucoma: A Feasibility Study. Koutsonas A; Walter P; Kuerten D; Plange N Biomed Res Int; 2018; 2018():4024198. PubMed ID: 30627553 [TBL] [Abstract][Full Text] [Related]
12. Telemetric non-contact intraocular pressure monitoring with an implanted sensor in patients with glaucoma: long-term safety report and monitoring data. Schmidt I; Plange N; Walter P; Koutsonas A Br J Ophthalmol; 2023 Aug; 107(8):1098-1103. PubMed ID: 35314512 [TBL] [Abstract][Full Text] [Related]
13. A Wireless Handheld Pressure Measurement System for In Vivo Monitoring of Intraocular Pressure in Rabbits. Phan A; Truong P; Camp A; Stewart K; Suen B; Weinreb RN; Talke FE IEEE Trans Biomed Eng; 2020 Mar; 67(3):931-937. PubMed ID: 31247540 [TBL] [Abstract][Full Text] [Related]
15. Device profile of the EYEMATE-IO™ system for intraocular pressure monitoring: overview of its safety and efficacy. Enders P; Cursiefen C Expert Rev Med Devices; 2020 Jun; 17(6):491-497. PubMed ID: 32339024 [TBL] [Abstract][Full Text] [Related]
16. A minimally invasive implantable wireless pressure sensor for continuous IOP monitoring. Chitnis G; Maleki T; Samuels B; Cantor LB; Ziaie B IEEE Trans Biomed Eng; 2013 Jan; 60(1):250-6. PubMed ID: 22736631 [TBL] [Abstract][Full Text] [Related]
17. Preliminary study on implantable inductive-type sensor for continuous monitoring of intraocular pressure. Kim YW; Kim MJ; Park KH; Jeoung JW; Kim SH; Jang CI; Lee SH; Kim JH; Lee S; Kang JY Clin Exp Ophthalmol; 2015 Dec; 43(9):830-7. PubMed ID: 26146890 [TBL] [Abstract][Full Text] [Related]
18. Intraocular pressure measurement precision with the Goldmann applanation, dynamic contour, and ocular response analyzer tonometers. Kotecha A; White E; Schlottmann PG; Garway-Heath DF Ophthalmology; 2010 Apr; 117(4):730-7. PubMed ID: 20122737 [TBL] [Abstract][Full Text] [Related]
19. Validation of rebound tonometry for intraocular pressure measurement in the rabbit. Zhang H; Yang D; Ross CM; Wigg JP; Pandav S; Crowston JG Exp Eye Res; 2014 Apr; 121():86-93. PubMed ID: 24561115 [TBL] [Abstract][Full Text] [Related]
20. Effect of intraocular pressure (IOP) and choroidal circulation on controlled episcleral drug delivery to retina/vitreous. Li J; Lan B; Li X; Sun S; Lu P; Cheng L J Control Release; 2016 Dec; 243():78-85. PubMed ID: 27717742 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]