These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1142 related articles for article (PubMed ID: 29066342)

  • 21. Outcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure.
    Barbanti M; Webb JG; Tamburino C; Van Mieghem NM; Makkar RR; Piazza N; Latib A; Sinning JM; Won-Keun K; Bleiziffer S; Bedogni F; Kapadia S; Tchetche D; Rodés-Cabau J; Fiorina C; Nombela-Franco L; De Marco F; de Jaegere PP; Chakravarty T; Vaquerizo B; Colombo A; Svensson L; Lange R; Nickenig G; Möllmann H; Walther T; Della Rosa F; Elhmidi Y; Dvir D; Brambilla N; Immè S; Sgroi C; Gulino S; Todaro D; Pilato G; Petronio AS; Tamburino C
    Circ Cardiovasc Interv; 2016 Sep; 9(9):. PubMed ID: 27578840
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Subclinical leaflet thrombosis in surgical and transcatheter bioprosthetic aortic valves: an observational study.
    Chakravarty T; Søndergaard L; Friedman J; De Backer O; Berman D; Kofoed KF; Jilaihawi H; Shiota T; Abramowitz Y; Jørgensen TH; Rami T; Israr S; Fontana G; de Knegt M; Fuchs A; Lyden P; Trento A; Bhatt DL; Leon MB; Makkar RR; ;
    Lancet; 2017 Jun; 389(10087):2383-2392. PubMed ID: 28330690
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Clinical Bioprosthetic Heart Valve Thrombosis After Transcatheter Aortic Valve Replacement: Incidence, Characteristics, and Treatment Outcomes.
    Jose J; Sulimov DS; El-Mawardy M; Sato T; Allali A; Holy EW; Becker B; Landt M; Kebernik J; Schwarz B; Richardt G; Abdel-Wahab M
    JACC Cardiovasc Interv; 2017 Apr; 10(7):686-697. PubMed ID: 28385406
    [TBL] [Abstract][Full Text] [Related]  

  • 24. SAPIEN S3 Leaflet Malfunction With Severe Intravalvular Aortic Insufficiency Immediately Post-Deployment.
    Singh GD; Southard JA; Smith TW; Boyd WD; Wong GB; Perry PA; Low RI
    JACC Cardiovasc Interv; 2017 Feb; 10(4):e31-e32. PubMed ID: 28231917
    [No Abstract]   [Full Text] [Related]  

  • 25. Abnormal distortion of aortic corevalve bioprosthesis with suicide left ventricle, aortic insufficiency, and severe mitral regurgitation during transcatheter aortic valve replacement.
    Leya F; Tuchek JM; Coats W
    Catheter Cardiovasc Interv; 2016 Dec; 88(7):1181-1187. PubMed ID: 26945836
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Three mechanisms of early failure of transcatheter aortic valves: Valve thrombosis, cusp rupture, and accelerated calcification.
    Summers MR; Cremer PC; Jaber WA
    J Thorac Cardiovasc Surg; 2017 May; 153(5):e87-e93. PubMed ID: 28073568
    [No Abstract]   [Full Text] [Related]  

  • 27. Transcatheter aortic valve implantation in degenerative sutureless perceval aortic bioprosthesis.
    Landes U; Sagie A; Kornowski R
    Catheter Cardiovasc Interv; 2018 Apr; 91(5):1000-1004. PubMed ID: 27696650
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Relationship of Annular Sizing Using Multidetector Computed Tomographic Imaging and Clinical Outcomes After Self-Expanding CoreValve Transcatheter Aortic Valve Replacement.
    Popma JJ; Gleason TG; Yakubov SJ; Harrison JK; Forrest JK; Maini B; Ruiz CE; Pinto DS; Costa M; Resar J; Conte J; Crestanello J; Chang Y; Oh JK; Reardon MJ; Adams DH
    Circ Cardiovasc Interv; 2016 Jul; 9(7):. PubMed ID: 27369803
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Transfemoral transcatheter aortic valve replacement in the presence of a mitral prosthesis.
    Toutouzas K; Drakopoulou M; Latsios G; Synetos A; Stathogiannis K; Soulaidopoulos S; Oikonomou G; Trantalis G; Papanikolaou A; Aggeli C; Vavuranakis M; Mastrokostopoulos A; Katsimaglis G; Voudris V; Dardas P; Tousoulis D
    J Cardiovasc Med (Hagerstown); 2019 Dec; 20(12):825-830. PubMed ID: 31592849
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Bypassing a bypass: transcatheter aortic valve replacement and percutaneous closure of a regurgitant apical-aortic conduit.
    Goldsweig AM
    J Cardiovasc Surg (Torino); 2017 Dec; 58(6):952-954. PubMed ID: 28920637
    [No Abstract]   [Full Text] [Related]  

  • 31. Computed Tomography-Based Oversizing Degrees and Incidence of Paravalvular Regurgitation of a New Generation Transcatheter Heart Valve.
    Blanke P; Pibarot P; Hahn R; Weissman N; Kodali S; Thourani V; Parvataneni R; Dvir D; Naoum C; Nørgaard BL; Douglas P; Jaber W; Khalique OK; Jilaihawi H; Mack M; Smith C; Leon M; Webb J; Leipsic J
    JACC Cardiovasc Interv; 2017 Apr; 10(8):810-820. PubMed ID: 28427598
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Aortic valve and left ventricular outflow tract calcium volume and distribution in transcatheter aortic valve replacement: Influence on the risk of significant paravalvular regurgitation.
    Hansson NC; Leipsic J; Pugliese F; Andersen HR; Rossi A; Simonato M; Jensen KT; Christiansen EH; Terkelsen CJ; Blanke P; Tang M; Krusell LR; Klaaborg KE; Terp K; Kennon S; Dvir D; Bøtker HE; Webb J; Nørgaard BL
    J Cardiovasc Comput Tomogr; 2018; 12(4):290-297. PubMed ID: 29519754
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Transcatheter aortic valve in valve implantation with bioprosthetic valve fracture.
    James TM; Stamou SC; Rothenberg M; Nores MA
    Catheter Cardiovasc Interv; 2019 May; 93(6):1170-1172. PubMed ID: 30790421
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Balloon Post-Dilation Following Implantation of a Self-Expanding Transcatheter Aortic Valve Bioprosthesis.
    Harrison JK; Hughes GC; Reardon MJ; Stoler R; Grayburn P; Hebeler R; Liu D; Chang Y; Popma JJ;
    JACC Cardiovasc Interv; 2017 Jan; 10(2):168-175. PubMed ID: 28104211
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Transcatheter aortic valve-in-valve implantation for failed surgical bioprosthetic valves. A minimalist approach without contrast aortography or echocardiographic guidance.
    Attinger-Toller A; Htun NM; Murdoch D; Perlman GY; Alenezi A; Sathananthan J; Blanke P; Leipsic J; Thompson C; Ye J; Cheung A; Wood D; Webb JG
    Catheter Cardiovasc Interv; 2020 Jan; 95(1):45-53. PubMed ID: 31038290
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Bioprosthetic aortic valve leaflet thrombosis detected by multidetector computed tomography is associated with adverse cerebrovascular events: a meta-analysis of observational studies.
    Rashid HN; Gooley RP; Nerlekar N; Ihdayhid AR; McCormick LM; Nasis A; Cameron JD; Brown AJ
    EuroIntervention; 2018 Feb; 13(15):e1748-e1755. PubMed ID: 29235436
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Predictors for Paravalvular Regurgitation After TAVR With the Self-Expanding Prosthesis: Quantitative Measurement of MDCT Analysis.
    Yoon SH; Ahn JM; Ohno Y; Barbanti M; Chan J; Lin MS; Kim YH; Yang DH; Sugiyama D; Chan KT; Immé S; Tamburino CI; Sgroi C; Park DW; Kang SJ; Lee SW; Lee CW; Park SW; Lee M; Kao HL; Tamburino C; Park SJ
    JACC Cardiovasc Imaging; 2016 Oct; 9(10):1233-1234. PubMed ID: 26777220
    [No Abstract]   [Full Text] [Related]  

  • 38. Transcatheter Aortic Valve Replacement: Role of Multimodality Imaging in Common and Complex Clinical Scenarios.
    Bax JJ; Delgado V; Hahn RT; Leipsic J; Min JK; Grayburn P; Sondergaard L; Yoon SH; Windecker S
    JACC Cardiovasc Imaging; 2020 Jan; 13(1 Pt 1):124-139. PubMed ID: 31103575
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Quantity and location of aortic valve complex calcification predicts severity and location of paravalvular regurgitation and frequency of post-dilation after balloon-expandable transcatheter aortic valve replacement.
    Khalique OK; Hahn RT; Gada H; Nazif TM; Vahl TP; George I; Kalesan B; Forster M; Williams MB; Leon MB; Einstein AJ; Pulerwitz TC; Pearson GD; Kodali SK
    JACC Cardiovasc Interv; 2014 Aug; 7(8):885-94. PubMed ID: 25147034
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Transapical transcatheter aortic valve replacement with a novel transcatheter aortic valve replacement system in high-risk patients with severe aortic valve diseases.
    Zhu L; Guo Y; Wang W; Liu H; Yang Y; Wei L; Wang C
    J Thorac Cardiovasc Surg; 2018 Feb; 155(2):588-597. PubMed ID: 28992963
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 58.