These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
151 related articles for article (PubMed ID: 29069704)
1. Saline with methylene blue-assisted endoscopic ultrasound-guided gastrojejunostomy using a double-flared fully covered metal stent. Wang G; Liu X; Wang S; Ge N; Guo J; Sun S Endoscopy; 2018 Jan; 50(1):E17-E19. PubMed ID: 29069704 [No Abstract] [Full Text] [Related]
2. Endoscopic ultrasound-guided gastrojejunostomy with a Nagi stent for relief of jejunal loop obstruction following hepaticojejunostomy. Chowdhury SD; Kurien RT; Bharath AK; Dutta AK; David D; Bharath CK; Joseph AJ Endoscopy; 2016; 48 Suppl 1():E263-4. PubMed ID: 27509466 [No Abstract] [Full Text] [Related]
3. How to treat intestinal obstruction due to malignant recurrence after Whipple's resection for pancreatic head cancer: Description of 2 new endoscopic techniques. Mouradides C; Taha A; Borbath I; Deprez PH; Moreels TG World J Gastroenterol; 2017 Sep; 23(33):6181-6186. PubMed ID: 28970734 [TBL] [Abstract][Full Text] [Related]
4. Endoscopic ultrasound-guided gastrojejunostomy using fully covered metal stent combined with large-loop double-pigtail stent for malignant afferent loop syndrome. Shiomi H; Kobayashi T; Sakai A; Shiomi Y; Masuda A; Bondoc EM; Kodama Y Endoscopy; 2019 Oct; 51(10):E303-E304. PubMed ID: 31121623 [No Abstract] [Full Text] [Related]
5. Duodenal stent placement for duodenal obstruction caused by pancreatic cancer associated with annular pancreas. Ogura T; Masuda D; Kurisu Y; Imoto A; Takii M; Uchiyama K; Higuchi K Gastrointest Endosc; 2014 Sep; 80(3):530-1. PubMed ID: 24890427 [No Abstract] [Full Text] [Related]
6. Treatment of afferent limb syndrome: novel approach with endoscopic ultrasound-guided creation of a gastrojejunostomy fistula and placement of lumen-apposing stent. Shah A; Khanna L; Sethi A Endoscopy; 2015; 47 Suppl 1 UCTN():E309-10. PubMed ID: 26115389 [No Abstract] [Full Text] [Related]
7. Afferent loop syndrome treated by endoscopic ultrasound-guided gastrojejunostomy, using a lumen-apposing metal stent with an electrocautery-enhanced delivery system. Yamamoto K; Tsuchiya T; Tanaka R; Mitsuyoshi H; Mukai S; Nagakawa Y; Itoi T Endoscopy; 2017 Nov; 49(11):E270-E272. PubMed ID: 28799148 [No Abstract] [Full Text] [Related]
8. Novel EUS-guided gastrojejunostomy technique using a new double-balloon enteric tube and lumen-apposing metal stent (with videos). Itoi T; Itokawa F; Uraoka T; Gotoda T; Horii J; Goto O; Moriyasu F; Moon JH; Kitagawa Y; Yahagi N Gastrointest Endosc; 2013 Dec; 78(6):934-939. PubMed ID: 24237949 [TBL] [Abstract][Full Text] [Related]
10. Laparoscopic modified Devine exclusion gastrojejunostomy as a palliative surgery to relieve malignant pyloroduodenal obstruction by unresectable cancer. Suzuki O; Shichinohe T; Yano T; Okamura K; Hazama K; Hirano S; Kondo S Am J Surg; 2007 Sep; 194(3):416-8. PubMed ID: 17693295 [TBL] [Abstract][Full Text] [Related]
11. Endoscopic choledochoduodenostomy and gastrojejunostomy in the treatment of biliary and duodenal obstruction. Abidi WM; Thompson CC Gastrointest Endosc; 2016 Jun; 83(6):1287-8. PubMed ID: 26684602 [No Abstract] [Full Text] [Related]
12. Covered metal stent placement followed by EUS-guided choledochoduodenostomy for balloon-assisted ERCP-induced duodenal perforation. Yang MJ; Kim JH; Hwang JC; Yoo BM Arab J Gastroenterol; 2019 Jun; 20(2):103-104. PubMed ID: 31153790 [No Abstract] [Full Text] [Related]
13. The Great View Forward: The Use of a Colonoscope for Distal Duodenal Stent Placement. Minervini A; Lauro A; Pagano N; Vaccari S; D'Andrea V; Marino IR; Cervellera M; Tonini V Dig Dis Sci; 2019 Sep; 64(9):2445-2448. PubMed ID: 31410750 [TBL] [Abstract][Full Text] [Related]
14. Endoscopic ultrasound-guided gastroenterostomy using a lumen-apposing self-expanding metal stent for decompression of afferent loop obstruction. Taunk P; Cosgrove N; Loren DE; Kowalski T; Siddiqui AA Endoscopy; 2015; 47 Suppl 1 UCTN():E395-6. PubMed ID: 26273778 [No Abstract] [Full Text] [Related]
16. Current status and perspective of endoscopic ultrasonography-guided gastrojejunostomy: endoscopic ultrasonography-guided double-balloon-occluded gastrojejunostomy (with videos). Itoi T; Ishii K; Tanaka R; Umeda J; Tonozuka R J Hepatobiliary Pancreat Sci; 2015 Jan; 22(1):3-11. PubMed ID: 25155270 [TBL] [Abstract][Full Text] [Related]
17. Increased rates of duodenal obstruction in pancreatic cancer patients receiving modern medical management. Shah A; Fehmi A; Savides TJ Dig Dis Sci; 2014 Sep; 59(9):2294-8. PubMed ID: 24781163 [TBL] [Abstract][Full Text] [Related]
18. Endoscopic ultrasound-guided transjejunal drainage of an obstructed afferent loop using a novel lumen-apposing metal stent. Lakhtakia S; Chavan R; Basha J; Nabi Z; Gupta R; Reddy DN Endoscopy; 2019 Sep; 51(9):E253-E254. PubMed ID: 31071747 [No Abstract] [Full Text] [Related]
19. Management of a necrosed bile duct by combination of a fully covered metal biliary stent and endoscopic ultrasound-guided gastrojejunostomy. DiMaio CJ; Cheesman AR; Nagula S; Kumta NA Endoscopy; 2021 May; 53(5):E172-E173. PubMed ID: 32818984 [No Abstract] [Full Text] [Related]
20. Temporary placement of a covered duodenal stent can avoid riskier anterograde biliary drainage when ERCP for obstructive jaundice fails due to duodenal invasion. Goutorbe F; Rouquette O; Mulliez A; Scanzi J; Goutte M; Dapoigny M; Abergel A; Poincloux L Surg Endosc; 2017 Feb; 31(2):625-631. PubMed ID: 27324333 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]