These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
136 related articles for article (PubMed ID: 29070960)
21. Modeling Elekta VersaHD using the Varian Eclipse treatment planning system for photon beams: A single-institution experience. Zhang Y; Le AH; Tian Z; Iqbal Z; Chiu T; Gu X; Pugachev A; Reynolds R; Park YK; Lin MH; Stojadinovic S J Appl Clin Med Phys; 2019 Oct; 20(10):33-42. PubMed ID: 31471950 [TBL] [Abstract][Full Text] [Related]
22. Investigating the Dosimetric Leaf Gap Correction Factor of Mobius3D Dose Calculation for Volumetric-modulated Arc Radiotherapy Plans. Sawapabmongkon T; Changkaew P; Puttanawarut C; Tangboonduangjit P; Khachonkham S J Med Phys; 2024; 49(2):261-269. PubMed ID: 39131432 [TBL] [Abstract][Full Text] [Related]
23. MLC parameters from static fields to VMAT plans: an evaluation in a RT-dedicated MC environment (PRIMO). Paganini L; Reggiori G; Stravato A; Palumbo V; Mancosu P; Lobefalo F; Gaudino A; Fogliata A; Scorsetti M; Tomatis S Radiat Oncol; 2019 Dec; 14(1):216. PubMed ID: 31791355 [TBL] [Abstract][Full Text] [Related]
24. [Multi-institutional Analysis of MLC Parameters for Commissioning of IMRT]. Shinoda K; Shida K; Hatanaka S Nihon Hoshasen Gijutsu Gakkai Zasshi; 2020; 76(4):404-409. PubMed ID: 32307368 [TBL] [Abstract][Full Text] [Related]
25. Performance of a multi leaf collimator system for MR-guided radiation therapy. Cai B; Li H; Yang D; Rodriguez V; Curcuru A; Wang Y; Wen J; Kashani R; Mutic S; Green O Med Phys; 2017 Dec; 44(12):6504-6514. PubMed ID: 28887825 [TBL] [Abstract][Full Text] [Related]
26. Small field segments surrounded by large areas only shielded by a multileaf collimator: comparison of experiments and dose calculation. Kron T; Clivio A; Vanetti E; Nicolini G; Cramb J; Lonski P; Cozzi L; Fogliata A Med Phys; 2012 Dec; 39(12):7480-9. PubMed ID: 23231297 [TBL] [Abstract][Full Text] [Related]
27. Dynamic MLC leaf sequencing for integrated linear accelerator control systems. Popple RA; Brezovich IA Med Phys; 2011 Nov; 38(11):6039-45. PubMed ID: 22047368 [TBL] [Abstract][Full Text] [Related]
28. Monte Carlo implementation, validation, and characterization of a 120 leaf MLC. Fix MK; Volken W; Frei D; Frauchiger D; Born EJ; Manser P Med Phys; 2011 Oct; 38(10):5311-20. PubMed ID: 21992349 [TBL] [Abstract][Full Text] [Related]
29. An oscillating sweeping gap test for VMAT quality assurance. Bhagwat MS; Han Z; Ng SK; Zygmanski P Phys Med Biol; 2010 Sep; 55(17):5029-44. PubMed ID: 20702923 [TBL] [Abstract][Full Text] [Related]
30. Characterizing a Geant4 Monte Carlo model of a multileaf collimator for a TrueBeam™ linear accelerator. Kandlakunta P; Momin S; Sloop A; Zhang T; Khan R Phys Med; 2019 Mar; 59():1-12. PubMed ID: 30928056 [TBL] [Abstract][Full Text] [Related]
31. Inter-unit variability of multi-leaf collimator parameters for IMRT and VMAT treatment planning: a multi-institutional survey. Isono M; Akino Y; Mizuno H; Tanaka Y; Masai N; Yamamoto T J Radiat Res; 2020 Mar; 61(2):307-313. PubMed ID: 31927580 [TBL] [Abstract][Full Text] [Related]
32. A strategy to determine off-axis dosimetric leaf gap using OSLD and EPID. Divyalakshmi J; Rafic KM; Babu ES; Balasingh TP; Sebastin A; Sujith CJ; Raj LJS Rep Pract Oncol Radiother; 2021; 26(6):1019-1028. PubMed ID: 34992876 [TBL] [Abstract][Full Text] [Related]
33. Evaluation of Dosimetric Effect of Millennium and High Definition Multi Leaf Collimator Using 6 MV Photon Beams. Raj A; Khanna D; Vt H; Padmanabhan S; Mohandass P Asian Pac J Cancer Prev; 2021 Dec; 22(12):3883-3888. PubMed ID: 34967567 [TBL] [Abstract][Full Text] [Related]
34. Validation and IMRT/VMAT delivery quality of a preconfigured fast-rotating O-ring linac system. De Roover R; Crijns W; Poels K; Michiels S; Nulens A; Vanstraelen B; Petillion S; De Brabandere M; Haustermans K; Depuydt T Med Phys; 2019 Jan; 46(1):328-339. PubMed ID: 30417523 [TBL] [Abstract][Full Text] [Related]
35. Development and commissioning of a multileaf collimator model in monte carlo dose calculations for intensity-modulated radiation therapy. Jang SY; Vassiliev ON; Liu HH; Mohan R; Siebers JV Med Phys; 2006 Mar; 33(3):770-81. PubMed ID: 16878579 [TBL] [Abstract][Full Text] [Related]
36. Commissioning of the tongue-and-groove modelling in treatment planning systems: from static fields to VMAT treatments. Hernandez V; Vera-Sánchez JA; Vieillevigne L; Saez J Phys Med Biol; 2017 Aug; 62(16):6688-6707. PubMed ID: 28639942 [TBL] [Abstract][Full Text] [Related]
37. An integral quality monitoring system for real-time verification of intensity modulated radiation therapy. Islam MK; Norrlinger BD; Smale JR; Heaton RK; Galbraith D; Fan C; Jaffray DA Med Phys; 2009 Dec; 36(12):5420-8. PubMed ID: 20095254 [TBL] [Abstract][Full Text] [Related]
38. Evaluation of MLC leaf positioning accuracy for static and dynamic IMRT treatments using DAVID in vivo dosimetric system. Karagoz G; Zorlu F; Yeginer M; Yildiz D; Ozyigit G J Appl Clin Med Phys; 2016 Mar; 17(2):14-23. PubMed ID: 27074451 [TBL] [Abstract][Full Text] [Related]
39. IMRT implementation and patient specific dose verification with film and ion chamber array detectors. Sathiyan S; Ravikumar M; Varatharaj C; Supe SS; Keshava SL Gulf J Oncolog; 2010 Jul; (8):20-7. PubMed ID: 20601335 [TBL] [Abstract][Full Text] [Related]
40. A novel methodology for the optimization of transmission and dosimetric leaf gap parameters. DiCostanzo DJ; Ayan AS J Appl Clin Med Phys; 2022 May; 23(5):e13565. PubMed ID: 35226392 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]