These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
492 related articles for article (PubMed ID: 29076734)
1. ADAP-GC 3.2: Graphical Software Tool for Efficient Spectral Deconvolution of Gas Chromatography-High-Resolution Mass Spectrometry Metabolomics Data. Smirnov A; Jia W; Walker DI; Jones DP; Du X J Proteome Res; 2018 Jan; 17(1):470-478. PubMed ID: 29076734 [TBL] [Abstract][Full Text] [Related]
2. ADAP-GC 3.0: Improved Peak Detection and Deconvolution of Co-eluting Metabolites from GC/TOF-MS Data for Metabolomics Studies. Ni Y; Su M; Qiu Y; Jia W; Du X Anal Chem; 2016 Sep; 88(17):8802-11. PubMed ID: 27461032 [TBL] [Abstract][Full Text] [Related]
3. ADAP-GC 2.0: deconvolution of coeluting metabolites from GC/TOF-MS data for metabolomics studies. Ni Y; Qiu Y; Jiang W; Suttlemyre K; Su M; Zhang W; Jia W; Du X Anal Chem; 2012 Aug; 84(15):6619-29. PubMed ID: 22747237 [TBL] [Abstract][Full Text] [Related]
4. Metabolomics Data Preprocessing Using ADAP and MZmine 2. Du X; Smirnov A; Pluskal T; Jia W; Sumner S Methods Mol Biol; 2020; 2104():25-48. PubMed ID: 31953811 [TBL] [Abstract][Full Text] [Related]
5. ADAP-GC 4.0: Application of Clustering-Assisted Multivariate Curve Resolution to Spectral Deconvolution of Gas Chromatography-Mass Spectrometry Metabolomics Data. Smirnov A; Qiu Y; Jia W; Walker DI; Jones DP; Du X Anal Chem; 2019 Jul; 91(14):9069-9077. PubMed ID: 31274283 [TBL] [Abstract][Full Text] [Related]
7. eRah: A Computational Tool Integrating Spectral Deconvolution and Alignment with Quantification and Identification of Metabolites in GC/MS-Based Metabolomics. Domingo-Almenara X; Brezmes J; Vinaixa M; Samino S; Ramirez N; Ramon-Krauel M; Lerin C; Díaz M; Ibáñez L; Correig X; Perera-Lluna A; Yanes O Anal Chem; 2016 Oct; 88(19):9821-9829. PubMed ID: 27584001 [TBL] [Abstract][Full Text] [Related]
8. An automated data analysis pipeline for GC-TOF-MS metabonomics studies. Jiang W; Qiu Y; Ni Y; Su M; Jia W; Du X J Proteome Res; 2010 Nov; 9(11):5974-81. PubMed ID: 20825247 [TBL] [Abstract][Full Text] [Related]
9. A novel approach to transforming a non-targeted metabolic profiling method to a pseudo-targeted method using the retention time locking gas chromatography/mass spectrometry-selected ions monitoring. Li Y; Ruan Q; Li Y; Ye G; Lu X; Lin X; Xu G J Chromatogr A; 2012 Sep; 1255():228-36. PubMed ID: 22342183 [TBL] [Abstract][Full Text] [Related]
10. Web Server for Peak Detection, Baseline Correction, and Alignment in Two-Dimensional Gas Chromatography Mass Spectrometry-Based Metabolomics Data. Tian TF; Wang SY; Kuo TC; Tan CE; Chen GY; Kuo CH; Chen CS; Chan CC; Lin OA; Tseng YJ Anal Chem; 2016 Nov; 88(21):10395-10403. PubMed ID: 27673369 [TBL] [Abstract][Full Text] [Related]
11. ADAP-KDB: A Spectral Knowledgebase for Tracking and Prioritizing Unknown GC-MS Spectra in the NIH's Metabolomics Data Repository. Smirnov A; Liao Y; Fahy E; Subramaniam S; Du X Anal Chem; 2021 Sep; 93(36):12213-12220. PubMed ID: 34455770 [TBL] [Abstract][Full Text] [Related]
12. Data Processing for GC-MS- and LC-MS-Based Untargeted Metabolomics. Yao L; Sheflin AM; Broeckling CD; Prenni JE Methods Mol Biol; 2019; 1978():287-299. PubMed ID: 31119670 [TBL] [Abstract][Full Text] [Related]
13. SIMAT: GC-SIM-MS data analysis tool. Ranjbar MR; Di Poto C; Wang Y; Ressom HW BMC Bioinformatics; 2015 Aug; 16():259. PubMed ID: 26283310 [TBL] [Abstract][Full Text] [Related]
14. Identifying and quantifying metabolites by scoring peaks of GC-MS data. Aggio RB; Mayor A; Reade S; Probert CS; Ruggiero K BMC Bioinformatics; 2014 Dec; 15(1):374. PubMed ID: 25492550 [TBL] [Abstract][Full Text] [Related]
15. One Step Forward for Reducing False Positive and False Negative Compound Identifications from Mass Spectrometry Metabolomics Data: New Algorithms for Constructing Extracted Ion Chromatograms and Detecting Chromatographic Peaks. Myers OD; Sumner SJ; Li S; Barnes S; Du X Anal Chem; 2017 Sep; 89(17):8696-8703. PubMed ID: 28752754 [TBL] [Abstract][Full Text] [Related]
16. Independent evaluation of a commercial deconvolution reporting software for gas chromatography mass spectrometry analysis of pesticide residues in fruits and vegetables. Norli HR; Christiansen A; Holen B J Chromatogr A; 2010 Mar; 1217(13):2056-64. PubMed ID: 20172528 [TBL] [Abstract][Full Text] [Related]
17. Detailed Investigation and Comparison of the XCMS and MZmine 2 Chromatogram Construction and Chromatographic Peak Detection Methods for Preprocessing Mass Spectrometry Metabolomics Data. Myers OD; Sumner SJ; Li S; Barnes S; Du X Anal Chem; 2017 Sep; 89(17):8689-8695. PubMed ID: 28752757 [TBL] [Abstract][Full Text] [Related]
18. Comparative evaluation of eight software programs for alignment of gas chromatography-mass spectrometry chromatograms in metabolomics experiments. Niu W; Knight E; Xia Q; McGarvey BD J Chromatogr A; 2014 Dec; 1374():199-206. PubMed ID: 25435458 [TBL] [Abstract][Full Text] [Related]
19. A comprehensive automatic data analysis strategy for gas chromatography-mass spectrometry based untargeted metabolomics. Zhang YY; Zhang Q; Zhang YM; Wang WW; Zhang L; Yu YJ; Bai CC; Guo JZ; Fu HY; She Y J Chromatogr A; 2020 Apr; 1616():460787. PubMed ID: 31864723 [TBL] [Abstract][Full Text] [Related]
20. Comparison of gas chromatography-pulsed flame photometric detection-mass spectrometry, automated mass spectral deconvolution and identification system and gas chromatography-tandem mass spectrometry as tools for trace level detection and identification. Dagan S J Chromatogr A; 2000 Feb; 868(2):229-47. PubMed ID: 10701673 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]