These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 29095101)

  • 21. Full-field measurement of micromotion around a cementless femoral stem using micro-CT imaging and radiopaque markers.
    Malfroy Camine V; Rüdiger HA; Pioletti DP; Terrier A
    J Biomech; 2016 Dec; 49(16):4002-4008. PubMed ID: 27823803
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Three-dimensional measurement of cemented femoral stem stability: an in vitro cadaver study.
    Speirs AD; Slomczykowski MA; Orr TE; Siebenrock K; Nolte LP
    Clin Biomech (Bristol, Avon); 2000 May; 15(4):248-55. PubMed ID: 10675665
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Micromotion of cemented and uncemented femoral components.
    Burke DW; O'Connor DO; Zalenski EB; Jasty M; Harris WH
    J Bone Joint Surg Br; 1991 Jan; 73(1):33-7. PubMed ID: 1991771
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The effect of primary stability on load transfer and bone remodelling within the uncemented resurfaced femur.
    Pal B; Gupta S
    Proc Inst Mech Eng H; 2011 Jun; 225(6):549-61. PubMed ID: 22034739
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Biomechanics of cemented and cementless prostheses.
    Jasty M; Burke D; Harris WH
    Chir Organi Mov; 1992; 77(4):349-58. PubMed ID: 1297569
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Early periprosthetic bone remodelling around cemented and uncemented custom-made femoral components and their uncemented acetabular cups.
    Mulier M; Jaecques SV; Raaijmaakers M; Nijs J; Van der Perre G; Jonkers I
    Arch Orthop Trauma Surg; 2011 Jul; 131(7):941-8. PubMed ID: 21246378
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The effect of collar and distal stem fixation on micromotion of the femoral stem in uncemented total hip arthroplasty.
    Whiteside LA; Easley JC
    Clin Orthop Relat Res; 1989 Feb; (239):145-53. PubMed ID: 2912614
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Epidemiology of periprosthetic femoral fractures in 5417 revision total hip arthroplasties: a 40-year experience.
    Abdel MP; Houdek MT; Watts CD; Lewallen DG; Berry DJ
    Bone Joint J; 2016 Apr; 98-B(4):468-74. PubMed ID: 27037428
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Strain distribution in the proximal femur with flexible composite and metallic femoral components under axial and torsional loads.
    Otani T; Whiteside LA; White SE
    J Biomed Mater Res; 1993 May; 27(5):575-85. PubMed ID: 8314810
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Femoral stem fixation in hip replacement. A biomechanical comparison of cementless and cemented prostheses.
    Phillips TW; Messieh SS; McDonald PD
    J Bone Joint Surg Br; 1990 May; 72(3):431-4. PubMed ID: 2341442
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Cemented and uncemented total hip arthroplasty using the same femoral component.
    Meding JB; Ritter MA; Davis KE; Hillery M
    Hip Int; 2016; 26(1):62-6. PubMed ID: 26449330
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A modular system for cemented and cementless implantation of femoral stem prostheses.
    Eingartner C; Volkmann R; Ilchmann T; Weise K; Weller S
    Surg Technol Int; 1998; 7():353-61. PubMed ID: 12722002
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The compression-rotation stem: an experimental study on the primary stability of a new revision hip stem.
    Kraenzlein J; Mazoochian F; Fottner A; Birkenmaier C; von Schulze Pellengahr C; Jansson V
    Proc Inst Mech Eng H; 2009 Jan; 223(1):45-52. PubMed ID: 19239066
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effect of distal stem geometry on interface motion in uncemented revision total hip prostheses.
    Kirk KL; Potter BK; Lehman RA; Xenos JS
    Am J Orthop (Belle Mead NJ); 2007 Oct; 36(10):545-9. PubMed ID: 18033566
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Periprosthetic femoral fracture within two years after total hip replacement: analysis of 437,629 operations in the nordic arthroplasty register association database.
    Thien TM; Chatziagorou G; Garellick G; Furnes O; Havelin LI; Mäkelä K; Overgaard S; Pedersen A; Eskelinen A; Pulkkinen P; Kärrholm J
    J Bone Joint Surg Am; 2014 Oct; 96(19):e167. PubMed ID: 25274795
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Stem geometry changes initial femoral fixation stability of a revised press-fit hip prosthesis: A finite element study.
    Russell RD; Huo MH; Rodrigues DC; Kosmopoulos V
    Technol Health Care; 2016 Nov; 24(6):865-872. PubMed ID: 27434281
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Quantification of holographic fringe data: comparison of intact and implanted femurs.
    Katz DM; Blatcher S; Shelton JC
    Med Eng Phys; 1998 Mar; 20(2):114-23. PubMed ID: 9679230
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Interface micromotion of uncemented femoral components from postmortem retrieved total hip replacements.
    Mann KA; Miller MA; Costa PA; Race A; Izant TH
    J Arthroplasty; 2012 Feb; 27(2):238-245.e1. PubMed ID: 21723696
    [TBL] [Abstract][Full Text] [Related]  

  • 39. In vitro testing of the deformation pattern and initial stability of a cementless stem coupled to an experimental femoral head, with increased offset and altered femoral neck angles.
    Wik TS; Enoksen C; Klaksvik J; Østbyhaug PO; Foss OA; Ludvigsen J; Aamodt A
    Proc Inst Mech Eng H; 2011 Aug; 225(8):797-808. PubMed ID: 21922956
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses.
    Engh CA; O'Connor D; Jasty M; McGovern TF; Bobyn JD; Harris WH
    Clin Orthop Relat Res; 1992 Dec; (285):13-29. PubMed ID: 1446429
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.