These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

214 related articles for article (PubMed ID: 29096249)

  • 1. An improved FIB sample preparation technique for site-specific plan-view specimens: A new cutting geometry.
    Li C; Habler G; Baldwin LC; Abart R
    Ultramicroscopy; 2018 Jan; 184(Pt A):310-317. PubMed ID: 29096249
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Applications of the FIB lift-out technique for TEM specimen preparation.
    Giannuzzi LA; Drown JL; Brown SR; Irwin RB; Stevie FA
    Microsc Res Tech; 1998 May; 41(4):285-90. PubMed ID: 9633946
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sample preparation toward seamless 3D imaging technique from micrometer to nanometer scale.
    Miyake A; Matsuno J; Toh S
    Microscopy (Oxf); 2014 Nov; 63 Suppl 1():i24-i25. PubMed ID: 25359821
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of cleaved wedge geometry for plan-view transmission electron microscopy sample preparation.
    Palisaitis J
    Microsc Res Tech; 2021 Dec; 84(12):3182-3190. PubMed ID: 34263987
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Plan-view sample preparation of a buried nanodots array by FIB with accurate EDS positioning in thickness direction.
    Zhong C; Lin L; Qi R; Cheng Y; Gao X; Huang R
    Ultramicroscopy; 2019 Dec; 207():112840. PubMed ID: 31505397
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Plan-view transmission electron microscopy specimen preparation for atomic layer materials using a focused ion beam approach.
    Lee LH; Yu CH; Wei CY; Lee PC; Huang JS; Wen CY
    Ultramicroscopy; 2019 Feb; 197():95-99. PubMed ID: 30537672
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Focused Ion Beam Preparation of Specimens for Micro-Electro-Mechanical System-based Transmission Electron Microscopy Heating Experiments.
    Vijayan S; Jinschek JR; Kujawa S; Greiser J; Aindow M
    Microsc Microanal; 2017 Aug; 23(4):708-716. PubMed ID: 28578727
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The focused ion beam fold-out: sample preparation method for transmission electron microscopy.
    Floresca HC; Jeon J; Wang JG; Kim MJ
    Microsc Microanal; 2009 Dec; 15(6):558-63. PubMed ID: 19804654
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In situ lift-out dedicated techniques using FIB-SEM system for TEM specimen preparation.
    Tomus D; Ng HP
    Micron; 2013 Jan; 44():115-9. PubMed ID: 22664233
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Combining Ar ion milling with FIB lift-out techniques to prepare high quality site-specific TEM samples.
    Huang Z
    J Microsc; 2004 Sep; 215(Pt 3):219-23. PubMed ID: 15312185
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The correlation between ion beam/material interactions and practical FIB specimen preparation.
    Prenitzer BI; Urbanik-Shannon CA; Giannuzzi LA; Brown SR; Irwin RB; Shofner TL; Stevie FA
    Microsc Microanal; 2003 Jun; 9(3):216-36. PubMed ID: 12807673
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transmission electron microscopy and atom probe specimen preparation from mechanically alloyed powder using the focused ion-beam lift-out technique.
    Choi PP; Kwon YS; Kim JS; Al-Kassab T
    J Electron Microsc (Tokyo); 2007 Apr; 56(2):43-9. PubMed ID: 17928320
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparing Xe
    Zhong X; Wade CA; Withers PJ; Zhou X; Cai C; Haigh SJ; Burke MG
    J Microsc; 2021 May; 282(2):101-112. PubMed ID: 33210738
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Theory and New Applications of Ex Situ Lift Out.
    Giannuzzi LA; Yu Z; Yin D; Harmer MP; Xu Q; Smith NS; Chan L; Hiller J; Hess D; Clark T
    Microsc Microanal; 2015 Aug; 21(4):1034-48. PubMed ID: 26223551
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Novel in-situ lamella fabrication technique for in-situ TEM.
    Canavan M; Daly D; Rummel A; McCarthy EK; McAuley C; Nicolosi V
    Ultramicroscopy; 2018 Jul; 190():21-29. PubMed ID: 29660687
    [TBL] [Abstract][Full Text] [Related]  

  • 16. 3D imaging of cells and tissues by focused ion beam/scanning electron microscopy (FIB/SEM).
    Drobne D
    Methods Mol Biol; 2013; 950():275-92. PubMed ID: 23086881
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Focused ion beam milling of vitreous water: prospects for an alternative to cryo-ultramicrotomy of frozen-hydrated biological samples.
    Marko M; Hsieh C; Moberlychan W; Mannella CA; Frank J
    J Microsc; 2006 Apr; 222(Pt 1):42-7. PubMed ID: 16734713
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A method for multidirectional TEM observation of a specific site at atomic resolution.
    Kamino T; Yaguchi T; Konno M; Ohnishi T; Ishitani T
    J Electron Microsc (Tokyo); 2004; 53(6):583-8. PubMed ID: 15582970
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Advanced preparation of plan-view specimens on a MEMS chip for
    Minenkov A; Šantić N; Truglas T; Aberl J; Vukušić L; Brehm M; Groiss H
    MRS Bull; 2022; 47(4):359-370. PubMed ID: 35968543
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A method for directly correlating site-specific cross-sectional and plan-view transmission electron microscopy of individual nanostructures.
    Schreiber DK; Adusumilli P; Hemesath ER; Seidman DN; Petford-Long AK; Lauhon LJ
    Microsc Microanal; 2012 Dec; 18(6):1410-8. PubMed ID: 23146147
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.