These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

87 related articles for article (PubMed ID: 29103217)

  • 1. Aortic valve replacement with the Carpentier-Edwards Perimount bioprosthesis: Clinical and hemodynamic evaluation.
    Carreço C; Saraiva F; Leite-Moreira A; Macedo F
    Rev Port Cir Cardiotorac Vasc; 2016; 23(3-4):111-117. PubMed ID: 29103217
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Outcomes of surgical aortic valve replacement using Carpentier-Edwards PERIMOUNT bioprosthesis series in elderly patients with severe aortic valve stenosis: a retrospective cohort study.
    Nishioka N; Yamada A; Ujihira K; Iba Y; Maruyama R; Hatta E; Kurimoto Y; Nakanishi K
    Gen Thorac Cardiovasc Surg; 2016 Dec; 64(12):728-734. PubMed ID: 27491542
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mid-term haemodynamic and clinical results after aortic valve replacement using the Freedom Solo stentless bioprosthesis versus the Carpentier Edwards Perimount stented bioprosthesis.
    van der Straaten EP; Rademakers LM; van Straten AH; Houterman S; Tan ME; Soliman Hamad MA
    Eur J Cardiothorac Surg; 2016 Apr; 49(4):1174-80. PubMed ID: 26224338
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surgical management of aortic valve disease in the elderly: A retrospective comparative study of valve choice using propensity score analysis.
    Accola KD; Scott ML; Palmer GJ; Thompson PA; Sand ME; Suarez-Cavalier JE; Bott JN; Ebra G
    J Heart Valve Dis; 2008 Jul; 17(4):355-64; discussion 365. PubMed ID: 18751463
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Durability after aortic valve replacement with the Mitroflow versus the Perimount pericardial bioprosthesis: a single-centre experience in 2393 patients.
    Nielsen PH; Hjortdal V; Modrau IS; Jensen H; Kimose HH; Terp K; Poulsen SH; Smerup M; Nielsen SL
    Eur J Cardiothorac Surg; 2016 Jun; 49(6):1705-10. PubMed ID: 26984983
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus.
    Wagner IM; Eichinger WB; Bleiziffer S; Botzenhardt F; Gebauer I; Guenzinger R; Bauernschmitt R; Lange R
    J Thorac Cardiovasc Surg; 2007 May; 133(5):1234-41. PubMed ID: 17467435
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Very long-term outcomes of the Carpentier-Edwards Perimount aortic valve in patients aged 50-65 years.
    Bourguignon T; Lhommet P; El Khoury R; Candolfi P; Loardi C; Mirza A; Boulanger-Lothion J; Bouquiaux-Stablo-Duncan AL; Marchand M; Aupart M
    Eur J Cardiothorac Surg; 2016 May; 49(5):1462-8. PubMed ID: 26530269
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ten-year comparison of pericardial tissue valves versus mechanical prostheses for aortic valve replacement in patients younger than 60 years of age.
    Weber A; Noureddine H; Englberger L; Dick F; Gahl B; Aymard T; Czerny M; Tevaearai H; Stalder M; Carrel TP
    J Thorac Cardiovasc Surg; 2012 Nov; 144(5):1075-83. PubMed ID: 22341653
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Aortic Valve Replacement With Carpentier-Edwards: Hemodynamic Outcomes for the 19-mm Valve.
    You JH; Jeong DS; Sung K; Kim WS; Carriere KC; Lee YT; Park PW
    Ann Thorac Surg; 2016 Jun; 101(6):2209-16. PubMed ID: 26872735
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Very long-term outcomes of the Carpentier-Edwards Perimount valve in aortic position.
    Bourguignon T; Bouquiaux-Stablo AL; Candolfi P; Mirza A; Loardi C; May MA; El-Khoury R; Marchand M; Aupart M
    Ann Thorac Surg; 2015 Mar; 99(3):831-7. PubMed ID: 25583467
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The effective orifice area/patient aortic annulus area ratio: a better way to compare different bioprostheses? A prospective randomized comparison of the Mosaic and Perimount bioprostheses in the aortic position.
    Eichinger WB; Botzenhardt F; Guenzinger R; Bleiziffer S; Keithahn A; Bauernschmitt R; Lange R
    J Heart Valve Dis; 2004 May; 13(3):382-8; discussion 388-9. PubMed ID: 15222284
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sutureless Perceval aortic valve in comparison with the stented Carpentier-Edwards Perimount aortic valve.
    König KC; Wahlers T; Scherner M; Wippermann J
    J Heart Valve Dis; 2014 Mar; 23(2):253-8. PubMed ID: 25076560
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Trans-catheter valve-in-valve implantation: in vitro hydrodynamic performance of the SAPIEN+cloth trans-catheter heart valve in the Carpentier-Edwards Perimount valves.
    Walther T; Dehdashtian MM; Khanna R; Young E; Goldbrunner PJ; Lee W
    Eur J Cardiothorac Surg; 2011 Nov; 40(5):1120-6. PubMed ID: 21466959
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of the effects of aortic valve replacement using 19-mm Carpentier-Edwards Perimount bioprosthesis and 19-mm Medtronic Mosaic bioprosthesis.
    Tanigawa K; Eishi K; Yamachika S; Hashizume K; Tada S; Yamane K; Izumi K; Takai H; Miura T; Nakaji S
    Ann Thorac Cardiovasc Surg; 2008 Apr; 14(2):81-7. PubMed ID: 18414344
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Carpentier-Edwards PERIMOUNT Magna bioprosthesis: a stented valve with stentless performance?
    Totaro P; Degno N; Zaidi A; Youhana A; Argano V
    J Thorac Cardiovasc Surg; 2005 Dec; 130(6):1668-74. PubMed ID: 16308014
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Long-term results with the Biocor-SJM stentless porcine aortic bioprosthesis.
    Vrandecic M; Fantini FA; Filho BG; de O; da C; Vrandecic E
    J Heart Valve Dis; 2002 Jan; 11(1):47-53. PubMed ID: 11843505
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Stentless vs. stented bioprosthesis for aortic valve replacement: A case matched comparison of long-term follow-up and subgroup analysis of patients with native valve endocarditis.
    Schaefer A; Dickow J; Schoen G; Westhofen S; Kloss L; Al-Saydali T; Reichenspurner H; Philipp SA; Detter C
    PLoS One; 2018; 13(1):e0191171. PubMed ID: 29338037
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hemodynamic Performance of Pericardial Bioprostheses in the Aortic Position.
    Lee H; Hwang HY; Sohn SH; Choi JW; Park JB; Kim KH; Kim KB
    Korean J Thorac Cardiovasc Surg; 2020 Oct; 53(5):285-290. PubMed ID: 33020346
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Very late outcomes for mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 25-year follow-up of 450 implantations.
    Bourguignon T; Bouquiaux-Stablo AL; Loardi C; Mirza A; Candolfi P; Marchand M; Aupart MR
    J Thorac Cardiovasc Surg; 2014 Nov; 148(5):2004-2011.e1. PubMed ID: 24667021
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Aortic and mitral valve replacement with the Carpentier-Edwards pericardial bioprosthesis: 10-year results.
    Murakami T; Eishi K; Nakano S; Kobayashi J; Sasako Y; Isobe F; Kosakai Y; Kito Y; Kawashima Y
    J Heart Valve Dis; 1996 Jan; 5(1):45-9. PubMed ID: 8834725
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.