160 related articles for article (PubMed ID: 29105972)
1. Sterilization effects on ultrathin film polymer coatings for silicon-based implantable medical devices.
Iqbal Z; Moses W; Kim S; Kim EJ; Fissell WH; Roy S
J Biomed Mater Res B Appl Biomater; 2018 Aug; 106(6):2327-2336. PubMed ID: 29105972
[TBL] [Abstract][Full Text] [Related]
2. Comparison between polyethylene glycol and zwitterionic polymers as antifouling coatings on wearable devices for selective antigen capture from biological tissue.
Robinson KJ; Coffey JW; Muller DA; Young PR; Kendall MA; Thurecht KJ; Grøndahl L; Corrie SR
Biointerphases; 2015 Dec; 10(4):04A305. PubMed ID: 26446192
[TBL] [Abstract][Full Text] [Related]
3. Protein diffusion characteristics in the hydrogels of poly(ethylene glycol) and zwitterionic poly(sulfobetaine methacrylate) (pSBMA).
Wu J; Xiao Z; He C; Zhu J; Ma G; Wang G; Zhang H; Xiao J; Chen S
Acta Biomater; 2016 Aug; 40():172-181. PubMed ID: 27142255
[TBL] [Abstract][Full Text] [Related]
4. Anti-biofouling Sulfobetaine Polymer Thin Films on Silicon and Silicon Nanopore Membranes.
Li L; Marchant RE; Dubnisheva A; Roy S; Fissell WH
J Biomater Sci Polym Ed; 2011; 22(1-3):91-106. PubMed ID: 20546677
[TBL] [Abstract][Full Text] [Related]
5. Determination of non-freezing water in different nonfouling materials by differential scanning calorimetry.
Ma G; Ji F; Lin W; Chen S
J Biomater Sci Polym Ed; 2022 Jun; 33(8):1012-1024. PubMed ID: 35073220
[TBL] [Abstract][Full Text] [Related]
6. Solvent or thermal extraction of ethylene oxide from polymeric materials: Medical device considerations.
Lucas AD; Forrey C; Saylor DM; Vorvolakos K
J Biomed Mater Res B Appl Biomater; 2018 Aug; 106(6):2455-2463. PubMed ID: 29226556
[TBL] [Abstract][Full Text] [Related]
7. Low-fouling electrospun PLLA films modified with zwitterionic poly(sulfobetaine methacrylate)-catechol conjugates.
Yang W; Sundaram HS; Ella JR; He N; Jiang S
Acta Biomater; 2016 Aug; 40():92-99. PubMed ID: 27265149
[TBL] [Abstract][Full Text] [Related]
8. Sterilization effects on starPEG coated polymer surfaces: characterization and cell viability.
Lleixà Calvet J; Grafahrend D; Klee D; Möller M
J Mater Sci Mater Med; 2008 Apr; 19(4):1631-6. PubMed ID: 18228118
[TBL] [Abstract][Full Text] [Related]
9. Probing the Surface Hydration of Nonfouling Zwitterionic and PEG Materials in Contact with Proteins.
Leng C; Hung HC; Sun S; Wang D; Li Y; Jiang S; Chen Z
ACS Appl Mater Interfaces; 2015 Aug; 7(30):16881-8. PubMed ID: 26159055
[TBL] [Abstract][Full Text] [Related]
10. In vitro and in vivo hemocompatibility assessment of ultrathin sulfobetaine polymer coatings for silicon-based implants.
Iqbal Z; Kim S; Moyer J; Moses W; Abada E; Wright N; Kim EJ; Park J; Fissell WH; Vartanian S; Roy S
J Biomater Appl; 2019 Aug; 34(2):297-312. PubMed ID: 30862226
[No Abstract] [Full Text] [Related]
11. Sterilization and strength of 70/30 polylactide cages: e-beam versus ethylene oxide.
Smit TH; Thomas KA; Hoogendoorn RJ; Strijkers GJ; Helder MN; Wuisman PI
Spine (Phila Pa 1976); 2007 Apr; 32(7):742-7. PubMed ID: 17414907
[TBL] [Abstract][Full Text] [Related]
12. Probing the weak interaction of proteins with neutral and zwitterionic antifouling polymers.
Wu J; Zhao C; Hu R; Lin W; Wang Q; Zhao J; Bilinovich SM; Leeper TC; Li L; Cheung HM; Chen S; Zheng J
Acta Biomater; 2014 Feb; 10(2):751-60. PubMed ID: 24120846
[TBL] [Abstract][Full Text] [Related]
13. Silane coatings of metallic biomaterials for biomedical implants: A preliminary review.
Somasundaram S
J Biomed Mater Res B Appl Biomater; 2018 Nov; 106(8):2901-2918. PubMed ID: 30091505
[TBL] [Abstract][Full Text] [Related]
14. Effects of sterilization on poly(ethylene glycol) hydrogels.
Kanjickal D; Lopina S; Evancho-Chapman MM; Schmidt S; Donovan D
J Biomed Mater Res A; 2008 Dec; 87(3):608-17. PubMed ID: 18186054
[TBL] [Abstract][Full Text] [Related]
15. Wear resistance of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted carbon fiber reinforced poly(ether ether ketone) liners against metal and ceramic femoral heads.
Yamane S; Kyomoto M; Moro T; Hashimoto M; Takatori Y; Tanaka S; Ishihara K
J Biomed Mater Res B Appl Biomater; 2018 Apr; 106(3):1028-1037. PubMed ID: 28485068
[TBL] [Abstract][Full Text] [Related]
16. Development of a SiYAlON glaze for improved osteoconductivity of implantable medical devices.
Bock RM; Marin E; Rondinella A; Boschetto F; Adachi T; McEntire BJ; Bal BS; Pezzotti G
J Biomed Mater Res B Appl Biomater; 2018 Apr; 106(3):1084-1096. PubMed ID: 28503805
[TBL] [Abstract][Full Text] [Related]
17. Enhancement of plasma protein adsorption and osteogenesis of hMSCs by functionalized siloxane coatings for titanium implants.
Martínez-Ibáñez M; Murthy NS; Mao Y; Suay J; Gurruchaga M; Goñi I; Kohn J
J Biomed Mater Res B Appl Biomater; 2018 Apr; 106(3):1138-1147. PubMed ID: 28544508
[TBL] [Abstract][Full Text] [Related]
18. Planning Implications Related to Sterilization-Sensitive Science Investigations Associated with Mars Sample Return (MSR).
Velbel MA; Cockell CS; Glavin DP; Marty B; Regberg AB; Smith AL; Tosca NJ; Wadhwa M; Kminek G; Meyer MA; Beaty DW; Carrier BL; Haltigin T; Hays LE; Agee CB; Busemann H; Cavalazzi B; Debaille V; Grady MM; Hauber E; Hutzler A; McCubbin FM; Pratt LM; Smith CL; Summons RE; Swindle TD; Tait KT; Udry A; Usui T; Westall F; Zorzano MP
Astrobiology; 2022 Jun; 22(S1):S112-S164. PubMed ID: 34904892
[TBL] [Abstract][Full Text] [Related]
19. Sterilization effects on poly(glycerol dodecanedioate): A biodegradable shape memory elastomer for biomedical applications.
Ramaraju H; McAtee AM; Akman RE; Verga AS; Bocks ML; Hollister SJ
J Biomed Mater Res B Appl Biomater; 2023 Apr; 111(4):958-970. PubMed ID: 36479954
[TBL] [Abstract][Full Text] [Related]
20. Poly(2-methacryloyloxyethyl phosphorylcholine) for protein conjugation.
Lewis A; Tang Y; Brocchini S; Choi JW; Godwin A
Bioconjug Chem; 2008 Nov; 19(11):2144-55. PubMed ID: 18973286
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]