236 related articles for article (PubMed ID: 29108815)
21. Continuous noninvasive arterial blood pressure monitoring using the vascular unloading technology during complex gastrointestinal endoscopy: a prospective observational study.
Nicklas JY; Beckmann D; Killat J; Petzoldt M; Reuter DA; Rösch T; Saugel B
J Clin Monit Comput; 2019 Feb; 33(1):25-30. PubMed ID: 29556885
[TBL] [Abstract][Full Text] [Related]
22. Oscillometric blood pressure measurement used for calibration of the arterial tonometry method contributes significantly to error.
Hansen S; Staber M
Eur J Anaesthesiol; 2006 Sep; 23(9):781-7. PubMed ID: 16723049
[TBL] [Abstract][Full Text] [Related]
23. Blood pressure monitoring during arrhythmia: agreement between automated brachial cuff and intra-arterial measurements.
Lakhal K; Ehrmann S; Martin M; Faiz S; Réminiac F; Cinotti R; Capdevila X; Asehnoune K; Blanloeil Y; Rozec B; Boulain T
Br J Anaesth; 2015 Oct; 115(4):540-9. PubMed ID: 26385663
[TBL] [Abstract][Full Text] [Related]
24. Continuous blood pressure monitoring via non-invasive radial artery applanation tonometry and invasive arterial catheter demonstrates good agreement in patients undergoing colon carcinoma surgery.
Sun J; Chen H; Zheng J; Mao B; Zhu S; Feng J
J Clin Monit Comput; 2017 Dec; 31(6):1189-1195. PubMed ID: 28000041
[TBL] [Abstract][Full Text] [Related]
25. Validity and reliability of central blood pressure estimated by upper arm oscillometric cuff pressure.
Climie RE; Schultz MG; Nikolic SB; Ahuja KD; Fell JW; Sharman JE
Am J Hypertens; 2012 Apr; 25(4):414-20. PubMed ID: 22223041
[TBL] [Abstract][Full Text] [Related]
26. Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit.
Langwieser N; Prechtl L; Meidert AS; Hapfelmeier A; Bradaric C; Ibrahim T; Laugwitz KL; Schmid RM; Wagner JY; Saugel B
Clin Res Cardiol; 2015 Jun; 104(6):518-24. PubMed ID: 25618259
[TBL] [Abstract][Full Text] [Related]
27. Comparison of the non-invasive Nexfin® monitor with conventional methods for the measurement of arterial blood pressure in moderate risk orthopaedic surgery patients.
Balzer F; Habicher M; Sander M; Sterr J; Scholz S; Feldheiser A; Müller M; Perka C; Treskatsch S
J Int Med Res; 2016 Aug; 44(4):832-43. PubMed ID: 27142436
[TBL] [Abstract][Full Text] [Related]
28. How to measure blood pressure using an arterial catheter: a systematic 5-step approach.
Saugel B; Kouz K; Meidert AS; Schulte-Uentrop L; Romagnoli S
Crit Care; 2020 Apr; 24(1):172. PubMed ID: 32331527
[TBL] [Abstract][Full Text] [Related]
29. The Accuracy of the CNAP® Device Compared with Invasive Radial Artery Measurements for Providing Continuous Noninvasive Arterial Blood Pressure Readings at a Medical Intensive Care Unit: A Method-Comparison Study.
Smolle KH; Schmid M; Prettenthaler H; Weger C
Anesth Analg; 2015 Dec; 121(6):1508-16. PubMed ID: 26496367
[TBL] [Abstract][Full Text] [Related]
30. Perioperative Noninvasive Blood Pressure Monitoring.
Kuck K; Baker PD
Anesth Analg; 2018 Aug; 127(2):408-411. PubMed ID: 29189276
[TBL] [Abstract][Full Text] [Related]
31. Arterial or cuff pressure: Clinical predictors among patients in shock in a critical care resuscitation unit.
Keville MP; Gelmann D; Hollis G; Beher R; Raffman A; Tanveer S; Jones K; Parker BM; Haase DJ; Tran QK
Am J Emerg Med; 2021 Aug; 46():109-115. PubMed ID: 33744746
[TBL] [Abstract][Full Text] [Related]
32. Oscillometric and intra-arterial blood pressure in children post-kidney transplantation: Is invasive blood pressure measurement always needed?
Marouane A; Cornelissen EAM; Nusmeier A; Bootsma-Robroeks CMHHT
Pediatr Transplant; 2019 Feb; 23(1):e13309. PubMed ID: 30362265
[TBL] [Abstract][Full Text] [Related]
33. Techniques for Non-Invasive Monitoring of Arterial Blood Pressure.
Meidert AS; Saugel B
Front Med (Lausanne); 2017; 4():231. PubMed ID: 29359130
[TBL] [Abstract][Full Text] [Related]
34. CONTINUOUS NON-INVASIVE ARTERIAL PRESSURE DEVICE AS AN ADJUNCT TO RECOGNIZE FLUCTUATING BLOOD PRESSURES DURING ELECTIVE CESAREAN SECTION UNDER SUBARACHNOID BLOCKADE (SAB).
Gupta D; Soskin V; Marjanovic M; Amhaz H; Mazumdar A
Middle East J Anaesthesiol; 2016 Feb; 23(4):385-400. PubMed ID: 27382807
[TBL] [Abstract][Full Text] [Related]
35. Non-invasive continuous arterial pressure monitoring with Nexfin does not sufficiently replace invasive measurements in critically ill patients.
Hohn A; Defosse JM; Becker S; Steffen C; Wappler F; Sakka SG
Br J Anaesth; 2013 Aug; 111(2):178-84. PubMed ID: 23485882
[TBL] [Abstract][Full Text] [Related]
36. Noninvasive continuous monitoring versus intermittent oscillometric measurements for the detection of hypotension during digestive endoscopy.
Phan AD; Neuschwander A; Perrod G; Rahmi G; Cellier C; Cholley B
PLoS One; 2020; 15(10):e0240241. PubMed ID: 33007051
[TBL] [Abstract][Full Text] [Related]
37. Comparison of Noninvasive Oscillometric and Intra-Arterial Blood Pressure Measurements in Children Admitted to the Pediatric Intensive Care Unit.
Kaur J; Bhargava S; Pooni PA; Bhat D; Dhooria GS; Arora K; Kakkar S; Gill K
J Pediatr Intensive Care; 2024 Jun; 13(2):155-161. PubMed ID: 38919689
[TBL] [Abstract][Full Text] [Related]
38. The 2020 "WHO Technical Specifications for Automated Non-Invasive Blood Pressure Measuring Devices With Cuff".
John O; Campbell NRC; Brady TM; Farrell M; Varghese C; Velazquez Berumen A; Velez Ruiz Gaitan LA; Toffelmire N; Ameel M; Mideksa M; Jaffe MG; Schutte AE; Khan T; Lopez Meneses LP
Hypertension; 2021 Mar; 77(3):806-812. PubMed ID: 33517681
[TBL] [Abstract][Full Text] [Related]
39. Measurement of blood pressure.
Saugel B; Dueck R; Wagner JY
Best Pract Res Clin Anaesthesiol; 2014 Dec; 28(4):309-22. PubMed ID: 25480763
[TBL] [Abstract][Full Text] [Related]
40. [Interest of the noninvasive techniques for the measurement of the blood pressure in critical care].
Riachy M; Azar M
J Med Liban; 2006; 54(1):17-21. PubMed ID: 17044628
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]