These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
124 related articles for article (PubMed ID: 29115945)
1. Mechanical strain to maxillary incisors during direct laryngoscopy. Engoren M; Rochlen LR; Diehl MV; Sherman SS; Jewell E; Golinski M; Begeman P; Cavanaugh JM BMC Anesthesiol; 2017 Nov; 17(1):151. PubMed ID: 29115945 [TBL] [Abstract][Full Text] [Related]
2. Does experience influence the forces exerted on maxillary incisors during laryngoscopy? A manikin study using the Macintosh laryngoscope. Bucx MJ; van Geel RT; Wegener JT; Robers C; Stijnen T Can J Anaesth; 1995 Feb; 42(2):144-9. PubMed ID: 7720158 [TBL] [Abstract][Full Text] [Related]
3. Forces applied to the maxillary incisors by video laryngoscopes and the Macintosh laryngoscope. Lee RA; van Zundert AA; Maassen RL; Wieringa PA Acta Anaesthesiol Scand; 2012 Feb; 56(2):224-9. PubMed ID: 22091734 [TBL] [Abstract][Full Text] [Related]
4. Forces applied to the maxillary incisors during video-assisted intubation. Lee RA; van Zundert AA; Maassen RL; Willems RJ; Beeke LP; Schaaper JN; van Dobbelsteen J; Wieringa PA Anesth Analg; 2009 Jan; 108(1):187-91. PubMed ID: 19095848 [TBL] [Abstract][Full Text] [Related]
5. Forces applied to the maxillary incisors during tracheal intubation and dental injury risks of intubation by beginners: a manikin study. Fukuda T; Sugimoto Y; Yamashita S; Toyooka H; Tanaka M Acta Anaesthesiol Taiwan; 2011 Mar; 49(1):12-5. PubMed ID: 21453897 [TBL] [Abstract][Full Text] [Related]
6. Forces acting on the maxillary incisor teeth during laryngoscopy using the Macintosh laryngoscope. Bucx MJ; Snijders CJ; van Geel RT; Robers C; van de Giessen H; Erdmann W; Stijnen T Anaesthesia; 1994 Dec; 49(12):1064-70. PubMed ID: 7864323 [TBL] [Abstract][Full Text] [Related]
7. Transverse forces exerted on the maxillary incisors during laryngoscopy. Bucx MJ; van der Vegt MH; Snijders CJ; Stijnen T; Wesselink PR Can J Anaesth; 1996 Jul; 43(7):665-71. PubMed ID: 8807170 [TBL] [Abstract][Full Text] [Related]
8. Determination of the distance between the laryngoscope blade and the upper incisors during direct laryngoscopy: comparisons of a curved, an angulated straight, and two straight blades. Watanabe S; Suga A; Asakura N; Takeshima R; Kimura T; Taguchi N; Kumagai M Anesth Analg; 1994 Oct; 79(4):638-41. PubMed ID: 7943768 [TBL] [Abstract][Full Text] [Related]
9. A mannequin study of intubation with the AP advance and GlideScope Ranger videolaryngoscopes and the Macintosh laryngoscope. Hodd JA; Doyle DJ; Gupta S; Dalton JE; Cata JP; Brewer EJ; James M; Sessler DI Anesth Analg; 2011 Oct; 113(4):791-800. PubMed ID: 21890882 [TBL] [Abstract][Full Text] [Related]
10. Does the incidence of sore throat postoperatively increase with the use of a traditional intubation blade or the GlideScope? Cirilla DJ; Ngo J; Vaisman V; Daly C; Ata A; Sandison M; Roberts K J Clin Anesth; 2015 Dec; 27(8):646-51. PubMed ID: 26277231 [TBL] [Abstract][Full Text] [Related]
11. Does the Miller blade truly provide a better laryngoscopic view and intubating conditions than the Macintosh blade in small children? Varghese E; Kundu R Paediatr Anaesth; 2014 Aug; 24(8):825-9. PubMed ID: 24690084 [TBL] [Abstract][Full Text] [Related]
12. Pressure on the incisors during direct laryngoscopy and intubation using the Shikani Optical Stylet™. Kucaba G; Muster M; Filip D; Horeczy B; Szarpak L; Woloszczuk-Gebicka B Am J Emerg Med; 2017 Sep; 35(9):1370-1372. PubMed ID: 28318802 [No Abstract] [Full Text] [Related]
13. [Comparison of five video laryngoscopes and conventional direct laryngoscopy : Investigations on simple and simulated difficult airways on the intubation trainer]. Ruetzler K; Imach S; Weiss M; Haas T; Schmidt AR Anaesthesist; 2015 Jul; 64(7):513-9. PubMed ID: 26174747 [TBL] [Abstract][Full Text] [Related]
14. The effectiveness of preformed tooth protectors during endotracheal intubation: an upper jaw model. Monaca E; Fock N; Doehn M; Wappler F Anesth Analg; 2007 Nov; 105(5):1326-32, table of contents. PubMed ID: 17959962 [TBL] [Abstract][Full Text] [Related]
15. Inverse intubation in entrapped trauma casualties: a simulator based, randomised cross-over comparison of direct, indirect and video laryngoscopy. Schober P; Krage R; van Groeningen D; Loer SA; Schwarte LA Emerg Med J; 2014 Dec; 31(12):959-63. PubMed ID: 24005641 [TBL] [Abstract][Full Text] [Related]
16. Indirect videolaryngoscopy using Macintosh blades in patients with non-anticipated difficult airways results in significantly lower forces exerted on teeth relative to classic direct laryngoscopy: a randomized crossover trial. Pieters B; Maassen R; Van Eig E; Maathuis B; Van Den Dobbelsteen J; Van Zundert A Minerva Anestesiol; 2015 Aug; 81(8):846-54. PubMed ID: 25311949 [TBL] [Abstract][Full Text] [Related]
17. Force applied during tracheal intubation. Bishop MJ; Harrington RM; Tencer AF Anesth Analg; 1992 Mar; 74(3):411-4. PubMed ID: 1539823 [TBL] [Abstract][Full Text] [Related]
18. Torque control of the maxillary incisors in lingual and labial orthodontics: a 3-dimensional finite element analysis. Liang W; Rong Q; Lin J; Xu B Am J Orthod Dentofacial Orthop; 2009 Mar; 135(3):316-22. PubMed ID: 19268829 [TBL] [Abstract][Full Text] [Related]
19. Warning devices for prevention of dental injury during laryngoscopy. Preliminary report. Ho AM; Hewitt G J Clin Monit Comput; 2000; 16(4):269-72. PubMed ID: 12578074 [TBL] [Abstract][Full Text] [Related]
20. The Callender modification of the Macintosh laryngoscope blade reduces the risk of tooth-blade contact in children. Mireskandari SM; Askarizadeh N; Darabi ME; Rahimi E; Ataee HA; Chamrami F; Eghtesadi-Araghi P Paediatr Anaesth; 2008 Nov; 18(11):1035-9. PubMed ID: 18950325 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]