These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

232 related articles for article (PubMed ID: 29116663)

  • 1. Higher contact force, energy setting, and impedance rise during radiofrequency ablation predicts charring: New insights from contact force-guided in vivo ablation.
    Makimoto H; Metzner A; Tilz RR; Lin T; Heeger CH; Rillig A; Mathew S; Lemeš C; Wissner E; Kuck KH; Ouyang F
    J Cardiovasc Electrophysiol; 2018 Feb; 29(2):227-235. PubMed ID: 29116663
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improving procedural and one-year outcome after contact force-guided pulmonary vein isolation: the role of interlesion distance, ablation index, and contact force variability in the 'CLOSE'-protocol.
    Phlips T; Taghji P; El Haddad M; Wolf M; Knecht S; Vandekerckhove Y; Tavernier R; Duytschaever M
    Europace; 2018 Nov; 20(FI_3):f419-f427. PubMed ID: 29315411
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Feasibility, efficacy, and safety of radiofrequency ablation of atrial fibrillation guided by monitoring of the initial impedance decrease as a surrogate of catheter contact.
    Reichlin T; Lane C; Nagashima K; Nof E; Chopra N; Ng J; Barbhaiya C; Tadros T; John RM; Stevenson WG; Michaud GF
    J Cardiovasc Electrophysiol; 2015 Apr; 26(4):390-396. PubMed ID: 25588901
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a multicentre European evaluation.
    Squara F; Zhao A; Marijon E; Latcu DG; Providencia R; Di Giovanni G; Jauvert G; Jourda F; Chierchia GB; De Asmundis C; Ciconte G; Alonso C; Grimard C; Boveda S; Cauchemez B; Saoudi N; Brugada P; Albenque JP; Thomas O
    Europace; 2015 May; 17(5):718-24. PubMed ID: 25840289
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impact of real-time contact force and impedance measurement in pulmonary vein isolation procedures for treatment of atrial fibrillation.
    Wakili R; Clauss S; Schmidt V; Ulbrich M; Hahnefeld A; Schüssler F; Siebermair J; Kääb S; Estner HL
    Clin Res Cardiol; 2014 Feb; 103(2):97-106. PubMed ID: 24096555
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Contact force and impedance decrease during ablation depends on catheter location and orientation: insights from pulmonary vein isolation using a contact force-sensing catheter.
    Knecht S; Reichlin T; Pavlovic N; Schaer B; Osswald S; Sticherling C; Kühne M
    J Interv Card Electrophysiol; 2015 Sep; 43(3):297-306. PubMed ID: 25925494
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Locations of high contact force during left atrial mapping in atrial fibrillation patients: electrogram amplitude and impedance are poor predictors of electrode-tissue contact force for ablation of atrial fibrillation.
    Nakagawa H; Kautzner J; Natale A; Peichl P; Cihak R; Wichterle D; Ikeda A; Santangeli P; Di Biase L; Jackman WM
    Circ Arrhythm Electrophysiol; 2013 Aug; 6(4):746-53. PubMed ID: 23873143
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vivo contact force analysis and correlation with tissue impedance during left atrial mapping and catheter ablation of atrial fibrillation.
    Makimoto H; Lin T; Rillig A; Metzner A; Wohlmuth P; Arya A; Antz M; Mathew S; Deiss S; Wissner E; Rausch P; Bardyszewski A; Kamioka M; Li X; Kuck KH; Ouyang F; Tilz RR
    Circ Arrhythm Electrophysiol; 2014 Feb; 7(1):46-54. PubMed ID: 24363353
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Recurrence after pulmonary vein isolation is associated with low contact force.
    Tofig BJ; Lukac P; Borregaard R; Nielsen JM; Jensen HK; Gerdes C; Kristensen J; Nielsen JC; Kristiansen SB
    Scand Cardiovasc J; 2018 Feb; 52(1):28-33. PubMed ID: 29191055
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mechanisms of pulmonary vein reconnection after radiofrequency ablation of atrial fibrillation: the deterministic role of contact force and interlesion distance.
    Park CI; Lehrmann H; Keyl C; Weber R; Schiebeling J; Allgeier J; Schurr P; Shah A; Neumann FJ; Arentz T; Jadidi AS
    J Cardiovasc Electrophysiol; 2014 Jul; 25(7):701-8. PubMed ID: 24575734
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ablation of paroxysmal atrial fibrillation using a second-generation cryoballoon catheter or contact-force sensing radiofrequency ablation catheter: A comparison of costs and long-term clinical outcomes.
    Yokokawa M; Chugh A; Latchamsetty R; Ghanbari H; Crawford T; Jongnarangsin K; Cunnane R; Saeed M; Hornsby K; Krishnasamy K; Lohawijarn W; Keast R; Karpenko D; Bogun F; Pelosi F; Morady F; Oral H
    J Cardiovasc Electrophysiol; 2018 Feb; 29(2):284-290. PubMed ID: 29071765
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of high-power short-duration (HPSD) ablation of atrial fibrillation using a contact force-sensing catheter and conventional technique: Initial results.
    Vassallo F; Cunha C; Serpa E; Meigre LL; Carloni H; Simoes A; Hespanhol D; Lovatto CV; Batista W; Serpa R
    J Cardiovasc Electrophysiol; 2019 Oct; 30(10):1877-1883. PubMed ID: 31397522
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters.
    Reichlin T; Knecht S; Lane C; Kühne M; Nof E; Chopra N; Tadros TM; Reddy VY; Schaer B; John RM; Osswald S; Stevenson WG; Sticherling C; Michaud GF
    Heart Rhythm; 2014 Feb; 11(2):194-201. PubMed ID: 24177370
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Atrial rhythm influences catheter tissue contact during radiofrequency catheter ablation of atrial fibrillation: comparison of contact force between sinus rhythm and atrial fibrillation.
    Matsuda H; Parwani AS; Attanasio P; Huemer M; Wutzler A; Blaschke F; Haverkamp W; Boldt LH
    Heart Vessels; 2016 Sep; 31(9):1544-52. PubMed ID: 26498938
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of energy source on early atrial fibrillation recurrences: a comparison of cryoballoon vs. radiofrequency current energy ablation with the endpoint of unexcitability in pulmonary vein isolation.
    Gunawardene MA; Hoffmann BA; Schaeffer B; Chung DU; Moser J; Akbulak RO; Jularic M; Eickholt C; Nuehrich J; Meyer C; Willems S
    Europace; 2018 Jan; 20(1):43-49. PubMed ID: 27742775
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cryoballoon antral pulmonary vein isolation vs contact force-sensing radiofrequency catheter ablation for pulmonary vein and posterior left atrial isolation in patients with persistent atrial fibrillation.
    Yokokawa M; Chugh A; Latchamsetty R; Ghanbari H; Crawford T; Jongnarangsin K; Cunnane R; Saeed M; Sunkara B; Tezcan M; Bogun F; Pelosi F; Morady F; Oral H
    Heart Rhythm; 2018 Dec; 15(12):1835-1841. PubMed ID: 30509365
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimization of catheter/tissue contact during pulmonary vein isolation: the impact of atrial rhythm.
    De Ponti R; Marazzi R; Doni LA; Marazzato J; Baratto C; Salerno-Uriarte JA
    Europace; 2018 Feb; 20(2):288-294. PubMed ID: 28069836
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Catheter-tissue contact force determines atrial electrogram characteristics before and lesion efficacy after antral pulmonary vein isolation in humans.
    Kumar S; Chan M; Lee J; Wong MC; Yudi M; Morton JB; Spence SJ; Halloran K; Kistler PM; Kalman JM
    J Cardiovasc Electrophysiol; 2014 Feb; 25(2):122-9. PubMed ID: 24102727
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A mesh-type flexible tip catheter vs a contact force catheter for catheter ablation of atrial fibrillation: A prospective nonrandomized 1:1 matched study.
    Pak HN; Park JW; Yang SY; Yu HT; Uhm JS; Joung B; Lee MH; Kim TH
    J Cardiovasc Electrophysiol; 2020 Jun; 31(6):1279-1288. PubMed ID: 32270578
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Safety and long-term effectiveness of paroxysmal atrial fibrillation ablation with a contact force-sensing catheter: real-world experience from a prospective, multicentre observational cohort registry.
    De Potter T; Van Herendael H; Balasubramaniam R; Wright M; Agarwal SC; Sanders P; Khaykin Y; Latcu DG; Maury P; Pani A; Hayes J; Kalman J; Nery P; Duncan E
    Europace; 2018 Nov; 20(FI_3):f410-f418. PubMed ID: 29315382
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.