These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

86 related articles for article (PubMed ID: 29125633)

  • 1. Usability of Functional MRI in Clinical Studies for Fast and Reliable Assessment of Renal Perfusion and Quantification of Hemodynamic Effects on the Kidney.
    Getzin T; May M; Schmidbauer M; Gutberlet M; Martirosian P; Oertel R; Wacker F; Schindler C; Hueper K
    J Clin Pharmacol; 2018 Apr; 58(4):466-473. PubMed ID: 29125633
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of arterial transit time and renal blood flow using pseudocontinuous ASL MRI with multiple post-labeling delays: Feasibility, reproducibility, and variation.
    Kim DW; Shim WH; Yoon SK; Oh JY; Kim JK; Jung H; Matsuda T; Kim D
    J Magn Reson Imaging; 2017 Sep; 46(3):813-819. PubMed ID: 28092411
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement of kidney perfusion by magnetic resonance imaging: comparison of MRI with arterial spin labeling to para-aminohippuric acid plasma clearance in male subjects with metabolic syndrome.
    Ritt M; Janka R; Schneider MP; Martirosian P; Hornegger J; Bautz W; Uder M; Schmieder RE
    Nephrol Dial Transplant; 2010 Apr; 25(4):1126-33. PubMed ID: 19934080
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reproducibility of Kidney Perfusion Measurements With Arterial Spin Labeling at 1.5 Tesla MRI Combined With Semiautomatic Segmentation for Differential Cortical and Medullary Assessment.
    Hammon M; Janka R; Siegl C; Seuss H; Grosso R; Martirosian P; Schmieder RE; Uder M; Kistner I
    Medicine (Baltimore); 2016 Mar; 95(11):e3083. PubMed ID: 26986143
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantification of Mouse Renal Perfusion Using Arterial Spin Labeled MRI at 1 T.
    Do QN; Madhuranthakam AJ; Bendel P; Lenkinski RE
    Acad Radiol; 2017 Sep; 24(9):1079-1085. PubMed ID: 28495212
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Diagnostic value of renal perfusion in patients with chronic kidney disease using 3D arterial spin labeling.
    Cai YZ; Li ZC; Zuo PL; Pfeuffer J; Li YM; Liu F; Liu RB
    J Magn Reson Imaging; 2017 Aug; 46(2):589-594. PubMed ID: 28181335
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A feasibility study on model-based evaluation of kidney perfusion measured by means of FAIR prepared true-FISP arterial spin labeling (ASL) on a 3-T MR scanner.
    Kiefer C; Schroth G; Gralla J; Diehm N; Baumgartner I; Husmann M
    Acad Radiol; 2009 Jan; 16(1):79-87. PubMed ID: 19064215
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent.
    Lüdemann L; Nafz B; Elsner F; Grosse-Siestrup C; Meissler M; Kaufels N; Rehbein H; Persson PB; Michaely HJ; Lengsfeld P; Voth M; Gutberlet M
    Invest Radiol; 2009 Mar; 44(3):125-34. PubMed ID: 19151609
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Longitudinal Assessment of Renal Perfusion and Oxygenation in Transplant Donor-Recipient Pairs Using Arterial Spin Labeling and Blood Oxygen Level-Dependent Magnetic Resonance Imaging.
    Niles DJ; Artz NS; Djamali A; Sadowski EA; Grist TM; Fain SB
    Invest Radiol; 2016 Feb; 51(2):113-20. PubMed ID: 26561047
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Volumetric Arterial Spin-labeled Perfusion Imaging of the Kidneys with a Three-dimensional Fast Spin Echo Acquisition.
    Robson PM; Madhuranthakam AJ; Smith MP; Sun MR; Dai W; Rofsky NM; Pedrosa I; Alsop DC
    Acad Radiol; 2016 Feb; 23(2):144-54. PubMed ID: 26521186
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Longitudinal evaluation of perfusion changes in acute and chronic renal allograft rejection using arterial spin labeling in translational mouse models.
    Hueper K; Schmidbauer M; Thorenz A; Bräsen JH; Gutberlet M; Mengel M; Hartung D; Chen R; Meier M; Haller H; Wacker F; Rong S; Gueler F
    J Magn Reson Imaging; 2017 Dec; 46(6):1664-1672. PubMed ID: 28342287
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantification of renal perfusion: comparison of arterial spin labeling and dynamic contrast-enhanced MRI.
    Winter JD; St Lawrence KS; Cheng HL
    J Magn Reson Imaging; 2011 Sep; 34(3):608-15. PubMed ID: 21761490
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Robust arterial spin labeling MRI measurement of pharmacologically induced perfusion change in rat kidneys.
    Zhao F; Zhou X; Messina E; Hu L; Holahan MA; Swaminath G; Hines CDG
    NMR Biomed; 2021 Sep; 34(9):e4566. PubMed ID: 34096123
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Arterial spin labeling blood flow magnetic resonance imaging for evaluation of renal injury.
    Liu YP; Song R; Liang Ch; Chen X; Liu B
    Am J Physiol Renal Physiol; 2012 Aug; 303(4):F551-8. PubMed ID: 22647631
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Arterial spin labeling MRI is able to detect early hemodynamic changes in diabetic nephropathy.
    Mora-Gutiérrez JM; Garcia-Fernandez N; Slon Roblero MF; Páramo JA; Escalada FJ; Wang DJ; Benito A; Fernández-Seara MA
    J Magn Reson Imaging; 2017 Dec; 46(6):1810-1817. PubMed ID: 28383796
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Perfusion quantitation in transplanted rat kidney by MRI with arterial spin labeling.
    Wang JJ; Hendrich KS; Jackson EK; Ildstad ST; Williams DS; Ho C
    Kidney Int; 1998 Jun; 53(6):1783-91. PubMed ID: 9607213
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantitative mouse renal perfusion using arterial spin labeling.
    Rajendran R; Lew SK; Yong CX; Tan J; Wang DJ; Chuang KH
    NMR Biomed; 2013 Oct; 26(10):1225-32. PubMed ID: 23592238
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Contrast-enhanced ultrasound identifies reduced overall and regional renal perfusion during global hypoxia in piglets.
    Brabrand K; de Lange C; Emblem KE; Reinholt FP; Saugstad OD; Stokke ES; Munkeby BH
    Invest Radiol; 2014 Aug; 49(8):540-6. PubMed ID: 24637585
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessment of Renal Perfusion in Transplanted Kidney Patients Using Pseudo-Continuous Arterial Spin Labeling with Multiple Post-Labeling Delays.
    Ahn HS; Yu HC; Kwak HS; Park SH
    Eur J Radiol; 2020 Sep; 130():109200. PubMed ID: 32739781
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Arterial Transit Time-corrected Renal Blood Flow Measurement with Pulsed Continuous Arterial Spin Labeling MR Imaging.
    Shimizu K; Kosaka N; Fujiwara Y; Matsuda T; Yamamoto T; Tsuchida T; Tsuchiyama K; Oyama N; Kimura H
    Magn Reson Med Sci; 2017 Jan; 16(1):38-44. PubMed ID: 27170422
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.