These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

86 related articles for article (PubMed ID: 2912614)

  • 1. The effect of collar and distal stem fixation on micromotion of the femoral stem in uncemented total hip arthroplasty.
    Whiteside LA; Easley JC
    Clin Orthop Relat Res; 1989 Feb; (239):145-53. PubMed ID: 2912614
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effects of the collar on total hip femoral component subsidence.
    Whiteside LA; Amador D; Russell K
    Clin Orthop Relat Res; 1988 Jun; (231):120-6. PubMed ID: 3370866
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Failure of cementless fixation of the femoral component in total hip arthroplasty.
    Otani T; Whiteside LA
    Orthop Clin North Am; 1992 Apr; 23(2):335-46. PubMed ID: 1570145
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Torsional fixation of a modular femoral hip component.
    Ohl MD; Whiteside LA; McCarthy DS; White SE
    Clin Orthop Relat Res; 1993 Feb; (287):135-41. PubMed ID: 8448932
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A conical-collared intramedullary stem can improve stress transfer and limit micromotion.
    Mandell JA; Carter DR; Goodman SB; Schurman DJ; Beaupré GS
    Clin Biomech (Bristol); 2004 Aug; 19(7):695-703. PubMed ID: 15288455
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reaming technique of the femoral diaphysis in cementless total hip arthroplasty.
    Otani T; Whiteside LA; White SE; McCarthy DS
    Clin Orthop Relat Res; 1995 Feb; (311):210-21. PubMed ID: 7634578
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of neck resection on torsional stability of cementless total hip replacement.
    Whiteside LA; White SE; McCarthy DS
    Am J Orthop (Belle Mead NJ); 1995 Oct; 24(10):766-70. PubMed ID: 8593558
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of a collar on subsidence and local micromotion of cementless femoral stems: in vitro comparative study based on micro-computerised tomography.
    Malfroy Camine V; Rüdiger HA; Pioletti DP; Terrier A
    Int Orthop; 2018 Jan; 42(1):49-57. PubMed ID: 28589313
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rotational stability of noncemented total hip femoral components.
    Whiteside LA; McCarthy DS; White SE
    Am J Orthop (Belle Mead NJ); 1996 Apr; 25(4):276-80. PubMed ID: 8728364
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Torsional fixation of the femoral component in total hip arthroplasty. The effect of surgical press-fit technique.
    Sugiyama H; Whiteside LA; Engh CA
    Clin Orthop Relat Res; 1992 Feb; (275):187-93. PubMed ID: 1735211
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Strain distribution in the proximal femur with flexible composite and metallic femoral components under axial and torsional loads.
    Otani T; Whiteside LA; White SE
    J Biomed Mater Res; 1993 May; 27(5):575-85. PubMed ID: 8314810
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Initial stability of a collarless wedge-shaped prosthesis in the femoral canal.
    Sharkey PF; Albert TJ; Hume EL; Rothman RH
    Semin Arthroplasty; 1990 Jul; 1(1):87-90. PubMed ID: 10149562
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of a collar on primary stability of standard and undersized cementless hip stems: a biomechanical study.
    Kistler M; Steinbrück A; Schmidutz F; Paulus AC; Holzapfel BM; Woiczinski M
    Arch Orthop Trauma Surg; 2024 Jun; 144(6):2873-2879. PubMed ID: 38762654
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of stem fit on bone hypertrophy and pain relief in cementless total hip arthroplasty.
    Whiteside LA
    Clin Orthop Relat Res; 1989 Oct; (247):138-47. PubMed ID: 2791383
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cementless implant composition and femoral stress. A finite element analysis.
    Namba RS; Keyak JH; Kim AS; Vu LP; Skinner HB
    Clin Orthop Relat Res; 1998 Feb; (347):261-7. PubMed ID: 9520899
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparative micromotion of fully and proximally cemented femoral stems.
    Bachus KN; Bloebaum RD; Jones RE
    Clin Orthop Relat Res; 1999 Sep; (366):248-57. PubMed ID: 10627742
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Uncemented femoral revision arthroplasty using the modular revision prosthesis MRP-TITAN revision stem.
    Mumme T; Müller-Rath R; Andereya S; Wirtz DC
    Oper Orthop Traumatol; 2007 Mar; 19(1):56-77. PubMed ID: 17345027
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The European school of total hip arthroplasty and 35 years of total hip arthroplasty in the Czech Republic.
    Cech O; Dzupa V
    Acta Chir Orthop Traumatol Cech; 2005; 72(1):57-76. PubMed ID: 15860155
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of surface finish and of vertical ribs on the stability of a cemented femoral stem: an in vitro stair climbing test.
    Jamali AA; Lozynsky AJ; Harris WH
    J Arthroplasty; 2006 Jan; 21(1):122-8. PubMed ID: 16446196
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Femoral strut allografts in cementless revision total hip arthroplasty.
    Pak JH; Paprosky WG; Jablonsky WS; Lawrence JM
    Clin Orthop Relat Res; 1993 Oct; (295):172-8. PubMed ID: 8403644
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.