132 related articles for article (PubMed ID: 29127555)
1. Continuous monitoring of blood pressure by analyzing the blood flow sound of arteriovenous fistula in hemodialysis patients.
Kamijo Y; Kanda E; Horiuchi H; Kounoue N; Ono K; Maeda K; Yanai A; Honda K; Tsujimoto R; Yanagi M; Ishibashi Y; Yoshida M
Clin Exp Nephrol; 2018 Jun; 22(3):677-683. PubMed ID: 29127555
[TBL] [Abstract][Full Text] [Related]
2. A continuous and non-invasive arterial pressure monitoring system in dialysis patients.
Mambelli E; Mancini E; Santoro A
Nephron Clin Pract; 2007; 107(4):c170-6. PubMed ID: 17975324
[TBL] [Abstract][Full Text] [Related]
3. Intra-dialytic blood oxygen saturation (SO
Mancini E; Perazzini C; Gesualdo L; Aucella F; Limido A; Scolari F; Savoldi S; Tramonti M; Corazza L; Atti M; Severi S; Bolasco P; Santoro A;
J Nephrol; 2017 Dec; 30(6):811-819. PubMed ID: 27572624
[TBL] [Abstract][Full Text] [Related]
4. Response of asymmetric dimethylarginine to hemodialysis-associated hypotension in end-stage renal disease patients.
Csiky B; Sulyok E; Lakatos O; Wittmann I; Martens-Lobenhoffer J; Bode-Boger SM
Nephron Clin Pract; 2008; 108(2):c127-34. PubMed ID: 18230915
[TBL] [Abstract][Full Text] [Related]
5. Intelligent system to predict intradialytic hypotension in chronic hemodialysis.
Lin CJ; Chen CY; Wu PC; Pan CF; Shih HM; Huang MY; Chou LH; Tang JS; Wu CJ
J Formos Med Assoc; 2018 Oct; 117(10):888-893. PubMed ID: 29941330
[TBL] [Abstract][Full Text] [Related]
6. [Effect of automated blood volume control on the incidence of intra-dialysis hypotension].
Germin Petrović D
Acta Med Croatica; 2003; 57(1):17-22. PubMed ID: 12876857
[TBL] [Abstract][Full Text] [Related]
7. Continuous measurement of pressure in internal arteriovenous fistulae and prevention of symptomatic hypotension during hemodialysis.
Nakane K; Shinzato T; Maeda K
ASAIO Trans; 1991; 37(3):M232-4. PubMed ID: 1751123
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of arteriovenous fistula for hemodialysis with a new generation digital stethoscope: a pilot study.
Presta P; Carullo N; Armeni A; Zicarelli MT; Musolino M; Bianco MG; Chiarella S; Andreucci M; Fiorillo AS; Pullano SA; Bolignano D; Coppolino G
Int Urol Nephrol; 2024 May; 56(5):1763-1771. PubMed ID: 38093038
[TBL] [Abstract][Full Text] [Related]
9. Brain natriuretic peptide in hemodialysis patients: predictive value for hemodynamic change during hemodialysis and cardiac function.
Matayoshi T; Kato T; Nakahama H; Nakata H; Yoshihara F; Kamide K; Horio T; Nakamura S; Kawano Y
Am J Nephrol; 2008; 28(1):122-7. PubMed ID: 17943021
[TBL] [Abstract][Full Text] [Related]
10. Blood pressure variation and its correlates among patients undergoing hemodialysis for renal failure in Benin City, Nigeria.
Okaka EI; Okwuonu CG
Ann Afr Med; 2017; 16(2):65-69. PubMed ID: 28469119
[TBL] [Abstract][Full Text] [Related]
11. Proto-dialytic cardiac function relates to intra-dialytic morbid events.
Kolb J; Kitzler TM; Tauber T; Morris N; Skrabal F; Kotanko P
Nephrol Dial Transplant; 2011 May; 26(5):1645-51. PubMed ID: 20923927
[TBL] [Abstract][Full Text] [Related]
12. The dialysis staff workload and the blood volume tracking system during the hemodialysis sessions of hypotension-prone patients.
Doria M; Genovesi S; Biagi F; Steckiph D; Mancini E; Stella A; Santoro A
Int J Artif Organs; 2014 Apr; 37(4):292-8. PubMed ID: 24811183
[TBL] [Abstract][Full Text] [Related]
13. Which dialysis unit blood pressure is the most accurate for predicting home blood pressure in patients undergoing hemodialysis?
Yoon IC; Choi HM; Oh DJ
Korean J Intern Med; 2017 Jan; 32(1):117-124. PubMed ID: 27052263
[TBL] [Abstract][Full Text] [Related]
14. Effect of Dialysis Day on Intradialytic Hypotension Risk.
Rocha A; Sousa C; Teles P; Coelho A; Xavier E
Kidney Blood Press Res; 2016; 41(2):168-74. PubMed ID: 26938587
[TBL] [Abstract][Full Text] [Related]
15. Relationship between different blood pressure measurements and left ventricular mass by cardiac magnetic resonance imaging in end-stage renal disease.
Merchant A; Wald R; Goldstein MB; Yuen D; Kirpalani A; Dacouris N; Ray JG; Kiaii M; Leipsic J; Kotha V; Deva D; Yan AT
J Am Soc Hypertens; 2015 Apr; 9(4):275-84. PubMed ID: 25753299
[TBL] [Abstract][Full Text] [Related]
16. Symmetric dimethylarginine is an independent predictor of intradialytic hypotension.
Mangoni AA; Hewitson CL; Woodman RJ; Whiting MJ; McAteer-Carr B; Barbara JA
Am J Hypertens; 2008 Aug; 21(8):955-9. PubMed ID: 18551101
[TBL] [Abstract][Full Text] [Related]
17. Study of arteriovenous fistula function by the temperature gradient method using the Twister™ device.
Roca-Tey R; Samon R; Ibrik O; Roda A; González-Oliva JC; Viladoms J
Nefrologia; 2012; 32(2):172-9. PubMed ID: 22425797
[TBL] [Abstract][Full Text] [Related]
18. Noninvasive continuous intradialytic blood pressure monitoring: the key to improving haemodynamic stability.
Stewart P; Stewart J
Curr Opin Nephrol Hypertens; 2021 Nov; 30(6):559-562. PubMed ID: 34456236
[TBL] [Abstract][Full Text] [Related]
19. Categorization of the hemodynamic response to hemodialysis: the importance of baroreflex sensitivity.
Chesterton LJ; Selby NM; Burton JO; Fialova J; Chan C; McIntyre CW
Hemodial Int; 2010 Jan; 14(1):18-28. PubMed ID: 19888950
[TBL] [Abstract][Full Text] [Related]
20. Feasibility of intermittent back-filtrate infusion hemodiafiltration to reduce intradialytic hypotension in patients with cardiovascular instability: a pilot study.
Koda Y; Aoike I; Hasegawa S; Osawa Y; Nakagawa Y; Iwabuchi F; Iwahashi C; Sugimoto T; Kikutani T
Clin Exp Nephrol; 2017 Apr; 21(2):324-332. PubMed ID: 27125432
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]