These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
118 related articles for article (PubMed ID: 29129323)
1. Haematological alterations in the cardiac patient after use of an autotransfusion system. Luque-Oliveros M Rev Esp Anestesiol Reanim (Engl Ed); 2018 Feb; 65(2):74-80. PubMed ID: 29129323 [TBL] [Abstract][Full Text] [Related]
2. [Pre and post-operative autotransfusion. A comparative study of hematology, biochemistry and red cell metabolism in pre-donated blood and blood from post-operative surgical drainage]. Muñoz Gómez M; Sánchez Arrieta Y; García Vallejo JJ; Mérida de la Torre FJ; Ruíz Romero de la Cruz MD; Eloy-García JM Sangre (Barc); 1999 Dec; 44(6):443-50. PubMed ID: 10822758 [TBL] [Abstract][Full Text] [Related]
3. Haematological effects of postoperative autotransfusion in spinal surgery. Riou B; Arock M; Guerrero M; Ramos M; Thoreux P; Guillosson JJ; Roy-Camille R; Viars P Acta Anaesthesiol Scand; 1994 May; 38(4):336-41. PubMed ID: 8067219 [TBL] [Abstract][Full Text] [Related]
5. Blood conservation for myocardial revascularization. Is it cost effective? Breyer RH; Engelman RM; Rousou JA; Lemeshow S J Thorac Cardiovasc Surg; 1987 Apr; 93(4):512-22. PubMed ID: 3104693 [TBL] [Abstract][Full Text] [Related]
6. [Autologous transfusion by peroperative salvage in orthotopic transplantation of the liver]. Houvenaeghel M; Lefèvre P; Samson D; Dyen J; Limet L; Manelli JC Ann Fr Anesth Reanim; 1989; 8(4):326-33. PubMed ID: 2817543 [TBL] [Abstract][Full Text] [Related]
7. [Post-operative retransfusion and intra-operative autotransfusion systems in total knee arthroplasty. A comparison of their efficacy]. Kučera B; Náhlík D; Hart R; Oceláková L Acta Chir Orthop Traumatol Cech; 2012; 79(4):361-6. PubMed ID: 22980936 [TBL] [Abstract][Full Text] [Related]
8. Blood clot formation in reinfusion bag with CATSmart: Two case reports. Kim JH; Bae JY; Lee SI; Heo MH; Kim KT; Park JS; Kim JY Int J Artif Organs; 2019 Nov; 42(11):668-672. PubMed ID: 31238769 [TBL] [Abstract][Full Text] [Related]
9. Ultrafiltration and reinfusion of residual cardiopulmonary bypass pump blood: A prospective non-randomized controlled study. Yan S; Zhao Y; Lou S Artif Organs; 2019 Jul; 43(7):641-646. PubMed ID: 30589449 [TBL] [Abstract][Full Text] [Related]
10. Pretransfusion Comparison of Dialyser-Based Hemoconcentrator With Cell Saver System for Perioperative Cell Salvage. Garg P; Malhotra A; Desai M; Sharma P; Bishnoi AK; Tripathi P; Rodricks D; Pandya H Innovations (Phila); 2015; 10(5):334-41. PubMed ID: 26418303 [TBL] [Abstract][Full Text] [Related]
11. [Effectiveness of the Cell Saver and salvage from ultrafiltered extracorporeal circulation in heart surgery]. Merville C; Charlet P; Zerr C; Bricard H Ann Fr Anesth Reanim; 1991; 10(6):548-53. PubMed ID: 1785706 [TBL] [Abstract][Full Text] [Related]
12. Patient blood management in elective total hip- and knee-replacement surgery (part 2): a randomized controlled trial on blood salvage as transfusion alternative using a restrictive transfusion policy in patients with a preoperative hemoglobin above 13 g/dl. So-Osman C; Nelissen RG; Koopman-van Gemert AW; Kluyver E; Pöll RG; Onstenk R; Van Hilten JA; Jansen-Werkhoven TM; van den Hout WB; Brand R; Brand A Anesthesiology; 2014 Apr; 120(4):852-60. PubMed ID: 24434302 [TBL] [Abstract][Full Text] [Related]
13. D-dimer levels in blood salvage for autotransfusion. Lawrence-Brown MM; Couch C; Halliday M; Hellings M; Barr A; Marshall L Aust N Z J Surg; 1989 Jan; 59(1):67-70. PubMed ID: 2913996 [TBL] [Abstract][Full Text] [Related]
14. Postoperative blood salvage and reinfusion in spinal surgery: blood quality, effectiveness and impact on patient blood parameters. Sebastián C; Romero R; Olalla E; Ferrer C; García-Vallejo JJ; Muñoz M Eur Spine J; 2000 Dec; 9(6):458-65. PubMed ID: 11189913 [TBL] [Abstract][Full Text] [Related]
15. Characteristics and quality of intra-operative cell salvage in paediatric scoliosis surgery. Perez-Ferrer A; Gredilla-Díaz E; de Vicente-Sánchez J; Navarro-Suay R; Gilsanz-Rodríguez F Rev Esp Anestesiol Reanim; 2016 Feb; 63(2):78-83. PubMed ID: 26162899 [TBL] [Abstract][Full Text] [Related]
16. Dynamic changes in clot formation determined using thromboelastometry after reinfusion of unwashed anticoagulated cell-salvaged whole blood in total hip arthroplasty. Froessler B; Weber I; Hodyl NA; Saadat-Gilani K Blood Transfus; 2015 Jul; 13(3):448-54. PubMed ID: 26192786 [TBL] [Abstract][Full Text] [Related]
17. Cell Saver Blood Reinfusion Up to 24 Hours Post Collection in Pediatric Cardiac Surgical Patients Does Not Increase Incidence of Hospital-Acquired Infections or Mortality. Boulos L; Kuebler JD; Angona R; Sweeney D; Wang H; Nocera E; Cholette JM J Extra Corpor Technol; 2021 Sep; 53(3):161-169. PubMed ID: 34658406 [TBL] [Abstract][Full Text] [Related]
18. [Autotransfusion after cardiac surgery. Hematological, biochemical and immunological properties of shed mediastinal blood]. Salas Millán J; de Vega N; Carmona Aurioles J; Negri Arjona S; García-Vallejo J; Muñoz Gómez M Rev Esp Anestesiol Reanim; 2001 Mar; 48(3):122-30. PubMed ID: 11333796 [TBL] [Abstract][Full Text] [Related]
19. Postoperative Blood Salvage and Autotransfusion for Adult Spinal Deformity: A Randomized Controlled Trial. Nemani VM; Kim HJ; Mina CA; Sheha ED; Ross T; Boachie-Adjei O Spine (Phila Pa 1976); 2020 Sep; 45(18):1247-1252. PubMed ID: 31361726 [TBL] [Abstract][Full Text] [Related]
20. Reinfusion of shed blood after orthopaedic procedures in children and adolescents. Blevins FT; Shaw B; Valeri CR; Kasser J; Hall J J Bone Joint Surg Am; 1993 Mar; 75(3):363-71. PubMed ID: 8444914 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]