These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 29131762)

  • 1. Strengths and Weaknesses of Synthetic Mammography in Screening.
    Ratanaprasatporn L; Chikarmane SA; Giess CS
    Radiographics; 2017; 37(7):1913-1927. PubMed ID: 29131762
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical implementation of synthesized mammography with digital breast tomosynthesis in a routine clinical practice.
    Freer PE; Riegert J; Eisenmenger L; Ose D; Winkler N; Stein MA; Stoddard GJ; Hess R
    Breast Cancer Res Treat; 2017 Nov; 166(2):501-509. PubMed ID: 28780702
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Synthetic Mammography: Benefits, Drawbacks, and Pitfalls.
    Chikarmane SA; Offit LR; Giess CS
    Radiographics; 2023 Oct; 43(10):e230018. PubMed ID: 37768863
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Two-view digital breast tomosynthesis screening with synthetically reconstructed projection images: comparison with digital breast tomosynthesis with full-field digital mammographic images.
    Skaane P; Bandos AI; Eben EB; Jebsen IN; Krager M; Haakenaasen U; Ekseth U; Izadi M; Hofvind S; Gullien R
    Radiology; 2014 Jun; 271(3):655-63. PubMed ID: 24484063
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calcifications at Digital Breast Tomosynthesis: Imaging Features and Biopsy Techniques.
    Horvat JV; Keating DM; Rodrigues-Duarte H; Morris EA; Mango VL
    Radiographics; 2019; 39(2):307-318. PubMed ID: 30681901
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison between two-dimensional synthetic mammography reconstructed from digital breast tomosynthesis and full-field digital mammography for the detection of T1 breast cancer.
    Choi JS; Han BK; Ko EY; Ko ES; Hahn SY; Shin JH; Kim MJ
    Eur Radiol; 2016 Aug; 26(8):2538-46. PubMed ID: 26628063
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Screening Mammography Findings From One Standard Projection Only in the Era of Full-Field Digital Mammography and Digital Breast Tomosynthesis.
    Cohen EO; Tso HH; Phalak KA; Mayo RC; Leung JWT
    AJR Am J Roentgenol; 2018 Aug; 211(2):445-451. PubMed ID: 29792742
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Synthesized Digital Mammography Imaging.
    Freer PE; Winkler N
    Radiol Clin North Am; 2017 May; 55(3):503-512. PubMed ID: 28411676
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Lesion conspicuity on synthetic screening mammography compared to full field digital screening mammography.
    Giess CS; Raza S; Denison CM; Yeh ED; Gombos EC; Frost EP; Bay CP; Chikarmane SA
    Clin Imaging; 2021 Jul; 75():90-96. PubMed ID: 33508756
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Digital breast tomosynthesis: Image acquisition principles and artifacts.
    Sujlana PS; Mahesh M; Vedantham S; Harvey SC; Mullen LA; Woods RW
    Clin Imaging; 2019; 55():188-195. PubMed ID: 30236642
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of synthetic mammography, reconstructed from digital breast tomosynthesis, and digital mammography: evaluation of lesion conspicuity and BI-RADS assessment categories.
    Mariscotti G; Durando M; Houssami N; Fasciano M; Tagliafico A; Bosco D; Casella C; Bogetti C; Bergamasco L; Fonio P; Gandini G
    Breast Cancer Res Treat; 2017 Dec; 166(3):765-773. PubMed ID: 28819781
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Digital breast tomosynthesis (DBT): a review of the evidence for use as a screening tool.
    Gilbert FJ; Tucker L; Young KC
    Clin Radiol; 2016 Feb; 71(2):141-50. PubMed ID: 26707815
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Synthesizing mammogram from digital breast tomosynthesis.
    Wei J; Chan HP; Helvie MA; Roubidoux MA; Neal CH; Lu Y; Hadjiiski LM; Zhou C
    Phys Med Biol; 2019 Feb; 64(4):045011. PubMed ID: 30625429
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Microcalcifications Detected at Screening Mammography: Synthetic Mammography and Digital Breast Tomosynthesis versus Digital Mammography.
    Lai YC; Ray KM; Lee AY; Hayward JH; Freimanis RI; Lobach IV; Joe BN
    Radiology; 2018 Dec; 289(3):630-638. PubMed ID: 30277445
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Conspicuity of Screen-Detected Malignancies on Full Field Digital Mammography vs. Synthetic Mammography.
    Chikarmane SA; Yeh ED; Wang A; Ratanaprasatporn L; Giess CS
    Acad Radiol; 2020 Jun; 27(6):757-763. PubMed ID: 31307930
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Review of radiation dose estimates in digital breast tomosynthesis relative to those in two-view full-field digital mammography.
    Svahn TM; Houssami N; Sechopoulos I; Mattsson S
    Breast; 2015 Apr; 24(2):93-9. PubMed ID: 25554018
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prospective Comparison of Synthesized Mammography with DBT and Full-Field Digital Mammography with DBT Uncovers Recall Disagreements That may Impact Cancer Detection.
    Huang ML; Hess K; Ma J; Santiago L; Scoggins ME; Arribas E; Adrada BE; Le-Petross HT; Leung JWT; Yang W; Geiser W; Candelaria RP
    Acad Radiol; 2022 Jul; 29(7):1039-1045. PubMed ID: 34538550
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Digital breast tomosynthesis versus full-field digital mammography: comparison of the accuracy of lesion measurement and characterization using specimens.
    Seo N; Kim HH; Shin HJ; Cha JH; Kim H; Moon JH; Gong G; Ahn SH; Son BH
    Acta Radiol; 2014 Jul; 55(6):661-7. PubMed ID: 24005560
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Synthesized Mammography: The New Standard of Care When Screening for Breast Cancer with Digital Breast Tomosynthesis?
    Ambinder EB; Harvey SC; Panigrahi B; Li X; Woods RW
    Acad Radiol; 2018 Aug; 25(8):973-976. PubMed ID: 29395801
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of full-field digital mammograms versus 2D synthesized mammograms for detection of microcalcifications on screening.
    Wahab RA; Lee SJ; Zhang B; Sobel L; Mahoney MC
    Eur J Radiol; 2018 Oct; 107():14-19. PubMed ID: 30292258
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.