166 related articles for article (PubMed ID: 29131809)
1. Positioning true coincidences that undergo inter-and intra-crystal scatter for a sub-mm resolution cadmium zinc telluride-based PET system.
Abbaszadeh S; Chinn G; Levin CS
Phys Med Biol; 2018 Jan; 63(2):025012. PubMed ID: 29131809
[TBL] [Abstract][Full Text] [Related]
2. Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography.
Habte F; Foudray AM; Olcott PD; Levin CS
Phys Med Biol; 2007 Jul; 52(13):3753-72. PubMed ID: 17664575
[TBL] [Abstract][Full Text] [Related]
3. Simulation study comparing high-purity germanium and cadmium zinc telluride detectors for breast imaging.
Campbell DL; Peterson TE
Phys Med Biol; 2014 Nov; 59(22):7059-79. PubMed ID: 25360792
[TBL] [Abstract][Full Text] [Related]
4. Characterization of a sub-assembly of 3D position sensitive cadmium zinc telluride detectors and electronics from a sub-millimeter resolution PET system.
Abbaszadeh S; Gu Y; Reynolds PD; Levin CS
Phys Med Biol; 2016 Sep; 61(18):6733-6753. PubMed ID: 27551981
[TBL] [Abstract][Full Text] [Related]
5. A maximum NEC criterion for Compton collimation to accurately identify true coincidences in PET.
Chinn G; Levin CS
IEEE Trans Med Imaging; 2011 Jul; 30(7):1341-52. PubMed ID: 21317079
[TBL] [Abstract][Full Text] [Related]
6. Design study of a high-resolution breast-dedicated PET system built from cadmium zinc telluride detectors.
Peng H; Levin CS
Phys Med Biol; 2010 May; 55(9):2761-88. PubMed ID: 20400807
[TBL] [Abstract][Full Text] [Related]
7. Effects of multiple-interaction photon events in a high-resolution PET system that uses 3-D positioning detectors.
Gu Y; Pratx G; Lau FW; Levin CS
Med Phys; 2010 Oct; 37(10):5494-508. PubMed ID: 21089785
[TBL] [Abstract][Full Text] [Related]
8. Photon quantum entanglement in the MeV regime and its application in PET imaging.
Watts DP; Bordes J; Brown JR; Cherlin A; Newton R; Allison J; Bashkanov M; Efthimiou N; Zachariou NA
Nat Commun; 2021 May; 12(1):2646. PubMed ID: 33976168
[TBL] [Abstract][Full Text] [Related]
9. Tilted angle CZT detector for photon counting/energy weighting x-ray and CT imaging.
Shikhaliev PM
Phys Med Biol; 2006 Sep; 51(17):4267-87. PubMed ID: 16912381
[TBL] [Abstract][Full Text] [Related]
10. Study of electrode pattern design for a CZT-based PET detector.
Gu Y; Levin CS
Phys Med Biol; 2014 Jun; 59(11):2599-621. PubMed ID: 24786208
[TBL] [Abstract][Full Text] [Related]
11. Bayesian reconstruction of photon interaction sequences for high-resolution PET detectors.
Pratx G; Levin CS
Phys Med Biol; 2009 Sep; 54(17):5073-94. PubMed ID: 19652293
[TBL] [Abstract][Full Text] [Related]
12. Scatter and crosstalk corrections for (99m)Tc/(123)I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators.
Fan P; Hutton BF; Holstensson M; Ljungberg M; Pretorius PH; Prasad R; Ma T; Liu Y; Wang S; Thorn SL; Stacy MR; Sinusas AJ; Liu C
Med Phys; 2015 Dec; 42(12):6895-911. PubMed ID: 26632046
[TBL] [Abstract][Full Text] [Related]
13. Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET.
Gu Y; Matteson JL; Skelton RT; Deal AC; Stephan EA; Duttweiler F; Gasaway TM; Levin CS
Phys Med Biol; 2011 Mar; 56(6):1563-84. PubMed ID: 21335649
[TBL] [Abstract][Full Text] [Related]
14. Inter-crystal scatter in a dual layer, high resolution LSO-APD positron emission tomograph.
Rafecas M; Böning G; Pichler BJ; Lorenz E; Schwaiger M; Ziegler SI
Phys Med Biol; 2003 Apr; 48(7):821-48. PubMed ID: 12701889
[TBL] [Abstract][Full Text] [Related]
15. A simulation of a high-resolution cadmium zinc telluride positron emission tomography system.
Stanford-Hill R; Groll A; Levin CS
Med Phys; 2024 Feb; 51(2):1340-1350. PubMed ID: 38100261
[TBL] [Abstract][Full Text] [Related]
16. SiPM signal readout for inter-crystal scatter event identification in PET detectors.
Park H; Lee JS
Phys Med Biol; 2020 Oct; 65(20):205010. PubMed ID: 32702670
[TBL] [Abstract][Full Text] [Related]
17. Intercrystal scatter studies for a 1 mm
Hsu DFC; Freese DL; Innes DR; Levin CS
Phys Med Biol; 2019 May; 64(9):095024. PubMed ID: 30893659
[TBL] [Abstract][Full Text] [Related]
18. A simulation study of 1D U-Net-based inter-crystal scatter event recovery of PET detectors.
Zou J; Ye J; Yu J; Cui K
Phys Med Biol; 2023 Jul; 68(14):. PubMed ID: 37364572
[TBL] [Abstract][Full Text] [Related]
19. Improved x-ray spectroscopy with room temperature CZT detectors.
Fritz SG; Shikhaliev PM; Matthews KL
Phys Med Biol; 2011 Sep; 56(17):5735-51. PubMed ID: 21841213
[TBL] [Abstract][Full Text] [Related]
20. Experimental Evaluation of a 3-D CZT Imaging Spectrometer for Potential Use in Compton-Enhanced PET Imaging.
Jin Y; Streicher M; Yang H; Brown S; He Z; Meng LJ
IEEE Trans Radiat Plasma Med Sci; 2023 Jan; 7(1):18-32. PubMed ID: 38106623
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]