BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

286 related articles for article (PubMed ID: 29134318)

  • 1. The impact of different peripheral suture techniques on the biomechanical stability in flexor tendon repair.
    Wieskötter B; Herbort M; Langer M; Raschke MJ; Wähnert D
    Arch Orthop Trauma Surg; 2018 Jan; 138(1):139-145. PubMed ID: 29134318
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical comparison of three epitendinous suture patterns as adjuncts to a core locking loop suture for repair of canine flexor tendon injuries.
    Cocca CJ; Duffy DJ; Kersh ME; Kim W; Groenewold A; Moore GE
    Vet Surg; 2019 Oct; 48(7):1245-1252. PubMed ID: 31222766
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Does Barbed Suture Repair Negate the Benefit of Peripheral Repair in Porcine Flexor Tendon?
    Sull A; Inceoglu S; Wongworawat MD
    Hand (N Y); 2016 Dec; 11(4):479-483. PubMed ID: 28149218
    [No Abstract]   [Full Text] [Related]  

  • 4. The effect of epitendinous suture technique on gliding resistance during cyclic motion after flexor tendon repair: a cadaveric study.
    Moriya T; Zhao C; An KN; Amadio PC
    J Hand Surg Am; 2010 Apr; 35(4):552-8. PubMed ID: 20189323
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of a continuous epitendinous suture as adjunct to three-loop pulley and locking-loop patterns for flexor tendon repair in a canine model.
    Putterman AB; Duffy DJ; Kersh ME; Rahman H; Moore GE
    Vet Surg; 2019 Oct; 48(7):1229-1236. PubMed ID: 31222767
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Flexor tendon repair with a knotless barbed suture: a comparative biomechanical study.
    Marrero-Amadeo IC; Chauhan A; Warden SJ; Merrell GA
    J Hand Surg Am; 2011 Jul; 36(7):1204-8. PubMed ID: 21664072
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of core suture material and peripheral repair technique on the strength of Kessler flexor tendon repair.
    Mishra V; Kuiper JH; Kelly CP
    J Hand Surg Br; 2003 Aug; 28(4):357-62. PubMed ID: 12849948
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical evaluation of flexor tendon repair techniques.
    Tang JB; Wang B; Chen F; Pan CZ; Xie RG
    Clin Orthop Relat Res; 2001 May; (386):252-9. PubMed ID: 11347844
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Flexor tendon repair: significant gain in strength from the Halsted peripheral suture technique.
    Wade PJ; Wetherell RG; Amis AA
    J Hand Surg Br; 1989 May; 14(2):232-5. PubMed ID: 2664057
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical Analysis of the Modified Kessler, Lahey, Adelaide, and Becker Sutures for Flexor Tendon Repair.
    Jordan MC; Schmitt V; Jansen H; Meffert RH; Hoelscher-Doht S
    J Hand Surg Am; 2015 Sep; 40(9):1812-7. PubMed ID: 26211716
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of barbed epitendinous sutures combined with a core locking-loop suture to repair experimental flexor tendon lacerations.
    Eby AC; Duffy DJ; Chang YJ; Gaffney L; Fisher MB; Moore GE
    Vet Surg; 2020 Dec; 49(8):1590-1599. PubMed ID: 32830868
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transosseous Sutures in Tendon-to-Bone Repairs: the Role of the Epitendinous Suture.
    Christen SM; Gruenert JG; Harenberg PS
    J Invest Surg; 2022 Mar; 35(3):584-590. PubMed ID: 33784920
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Symmetric Peripheral Running Sutures are Superior to Asymmetric Peripheral Running Sutures for Increasing the Tendon Strength in Flexor Tendon Repair.
    Takeuchi N; Okada T; Kozono N; Shimoto T; Higaki H; Iwamoto Y
    J Hand Surg Asian Pac Vol; 2017 Jun; 22(2):208-213. PubMed ID: 28506161
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Positioning of the cross-stitch on the modified Kessler core tendon suture.
    Gil-Santos L; Monleón-Pradas M; Gomar-Sancho F; Más-Estellés J
    J Mech Behav Biomed Mater; 2018 Apr; 80():27-32. PubMed ID: 29414472
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical Comparison of a Horizontal Mattress, Cross Suture and Vertical Mattress for Repair of a Tendon Weave in a Porcine Model.
    Senju T; Takeuchi N; Kozono N; Higaki H; Shimoto T; Nakashima Y
    J Hand Surg Asian Pac Vol; 2022 Jun; 27(3):439-446. PubMed ID: 35808873
    [No Abstract]   [Full Text] [Related]  

  • 16. Does plastic suture deformation induce gapping after tendon repair? A biomechanical comparison of different suture materials.
    Jordan MC; Boelch S; Jansen H; Meffert RH; Hoelscher-Doht S
    J Biomech; 2016 Sep; 49(13):2607-2612. PubMed ID: 27264620
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of barbed suture tendon repair on work of flexion.
    Ben-Amotz O; Kargel J; Mailey B; Sammer DM
    J Hand Surg Am; 2015 May; 40(5):969-74. PubMed ID: 25817753
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro cyclic tensile testing of combined peripheral and core flexor tenorrhaphy suture techniques.
    Tran HN; Cannon DL; Lieber RL; Abrams RA
    J Hand Surg Am; 2002 May; 27(3):518-24. PubMed ID: 12015729
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair.
    Lawrence TM; Davis TR
    J Hand Surg Am; 2005 Jul; 30(4):836-41. PubMed ID: 16039381
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of partial vs complete circumferential epitendinous suture placement on the biomechanical properties and gap formation of canine cadaveric tendons.
    Duffy DJ; Chang YJ; Fisher MB; Moore GE
    Vet Surg; 2020 Dec; 49(8):1571-1579. PubMed ID: 32812666
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.